Behringer Digital Mixer X32, X32 CORE, X32 COMPACT-TP, X32 RACK, X32-TP Protocol Manual

...
0 (0)

X32 MIDI Implementation (06 May 2014)

MIDI RX > SCENES

Whenever program change messages in the range 1-100 are received on MIDI CH01, the corresponding scene of the X32 internal show memory will be loaded.

This requires the following preconditions:

Setup / remote

MIDI In/Out check marks must be set according to the connection on which MIDI input will be accepted (via physical MIDI connectors on X32 or S16, or via XUF Card)

MIDI In/Out check mark must be set for “Enable MIDI Scene Recall”

Setup / global

when tick mark “Confirm Pop-Ups” / “Scene Load” is active, also MIDI scene recalls will only become active after manual confirmation

if you prefer activating scenes via MIDI program changes immediately, un-check the “Confirm Pop-Ups” / “Scene Load” tick mark

Scenes View / home

valid scenes must be stored in the internal X32 show file. It is not possible to recall empty scenes.

the scope of changes applied by a MIDI scene recall depends on the Scene Safes, Parameter Safes and Channel Safes settings, same as with recalling the scene locally.

MIDI TX > SCENES

Every scene can be assigned one specific MIDI command/event. Each time the scene is loaded the MIDI command will be sent out once. Possible choices for MIDI commands/events to be found on Scenes View/MIDI page:

Off > no message will be sent upon scene load

Program Change > select the MIDI Channel and the Program Number (using knobs 4/5 at the main display)

Control Change > select the MIDI Channel, Controller number and value (using knobs 4-6 at the main display)

Note > select the MIDI Channel, Note number and velocity (using knobs 4-6 at the main display)

will send out a Note On command directly followed by the same Note Off command

music-group.com

1

behringer.com

Behringer Digital Mixer X32, X32 CORE, X32 COMPACT-TP, X32 RACK, X32-TP Protocol Manual

PERMANENT MIDI ASSIGNMENTS OVERVIEW (REMOTE OFF)

MIDI RX

Midi Ch

Controller

Value

Comment

Scenes

1

Program Change

1-100

 

 

 

 

 

 

Snippet

2

Program Change

1-100

 

 

 

 

 

 

Cue

3-6

Program Change

0-127

Ch3 -> Cue 1-127, Ch4 -> Cue 128-255, etc.

 

 

 

 

 

Mute Groups

2

CC80-85

on (127) / off (0), toggle latching

 

 

 

 

 

 

Faders

1

CC0-79

0-127

Value 95 = 0dB

 

 

 

 

 

Mute

2

CC0-79

on (127) / off (0), toggle latching

 

 

 

 

 

 

Pan

3

CC0-79

1-127

Value 64 = Pan Mid

 

 

 

 

 

MIDI TX

Midi Ch

Controller

 

Value

Comment

Mute Groups

2

CC80-85

on (127)

/ off (0), toggle latching

 

 

 

 

 

 

 

Faders

1

CC0-79

 

0-127

Value 95 = 0dB

 

 

 

 

 

 

Mute

2

CC0-79

on (127)

/ off (0), toggle latching

 

 

 

 

 

 

 

Pan

3

CC0-79

 

1-127

Value 64 = Pan Mid

 

 

 

 

 

 

MIDI RX > ASSIGN

Whenever assignable controls are set up for transmitting MIDI commands, reception of that same command (status or continuous) will be reflected on the respective assignable control element (button light, encoder LED collar).

MIDI TX > ASSIGN

We restricted the user assignable MIDI commands to some generic elements, in order to keep things simple enough:

Encoders 1-4 > can be assigned to sending control changes, program changes or notes

parameters are currently ‘Channel’ and ‘Value’

for CC and Note commands ‘Value’ = controller number/note number, and the encoder rotation determines the controller value/note-on velocity

for Program Changes only the channel is specified, and the encoder rotation determines the program number

Buttons 5-12 > can be operated in two modes, ‘MIDI Push’ (non-latching) for momentary commands, or ‘MIDI Toggle’ (latching) for static commands

music-group.com