General Notes
Table of contents
1.
General Notes 2
Notes on the documentation 2 Liability conditions 2 Description of safety symbols 2 Basic safety measures 3 Operator's obligation to exercise diligence 3
2.
Installation instructions 4
Appropriate use 4 Frame sizes and descriptions 4 Scope of supply 4 Mounting 4
Mounting of the wall mounting frame 4 Attaching the brackets to the Control Panel 5 Inserting the Control Panel 6
Dismounting the Control Panel 6
3.
Assembly dimensions 7
Beckhoff Support & Service 10
Beckhoff branches and partner companies 10 Beckhoff Headquarters 10 Beckhoff Support 10 Beckhoff Service 10
C9900 wall mounting frame 1
General Notes

General Notes

Notes on the documentation

This description is only intended for the use of trained specialists in control
and automation engineering who are familiar with the applicable national standards. It is essential that the following notes and explanations are followed when installing and commissioning these components.

Liability conditions

The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations, guidelines and standards.
The documentation has been prepared with care. The products described are, however, constantly under development. For this reason, the documentation may not always be have been fully checked for consistency with the performance data, standards or other characteristics described. None of the statements in this manual represent a guarantee for as set out in § 443 of the German Civil Code or a statement about the assumed use according to the contract as set out in § 434 para. 1 clause 1 no. 1 of the German Civil Code. In the event that it contains technical or editorial errors, we retain the right to make alterations at any time and without warning. No claims for the modification of products that have already been supplied may be made on the basis of the data, diagrams and descriptions in this documentation.
© This documentation is protected by copyright. Any reproduction or third party use of this publication, whether in whole or in part, without the written permission of Beckhoff Automation GmbH, is forbidden.

Description of safety symbols

The following safety symbols are used in this operating manual. They are
intended to alert the reader to the associated safety instructions.
This symbol is intended to highlight risks for the life or health of personnel.
This symbol is intended to highlight risks for equipment, materials or the environment.
This symbol indicates information that contributes to better understanding.
i
Danger
Warning
Note
2 C9900 wall mounting frame
General Notes

Basic safety measures

The wall mounting frame may only be used in conjunction with the
i
Note
designated Beckhoff Control Panel.
Before installing and removing the Control Panel, all system
Warning
components must be switched off, and the Control Panel must be uncoupled from the system.
Disconnect the device by unplugging the connectors on the Control Panel side.
System components that have been switched off must be secured against being switched on again.

Operator's obligation to exercise diligence

Only qualified personnel may install the Control Panel in the wall
Warning
Warning
mounting frame.
The operator must ensure that only appropriately trained electricians deal with installation and wiring of the Control Panel.
After installation check the Control Panel for secure fastening in the frame.
Ensure that inadvertent detachment of the Control Panel from the wall mounting frame is prevented.
C9900 wall mounting frame 3
Installation instructions

Installation instructions

The C9900 wall mounting frame is designed for Beckhoff Control Panels.

Appropriate use

For possible frame and panel combinations please refer to section Frame
sizes and descriptions.
The stainless steel mounting frame can be flush-mounted in a solid wall or screw-mounted in a dry wall.

Frame sizes and descriptions

Frame descriptions
The following frames are available for the different panel sizes:
C9900-M298 - panel mounting frame for CP6608
C9900-M311 - panel mounting frame for CP6609/CP6909
C9900-M313 - panel mounting frame for CP6601/CP6901
C9900-M314 - panel mounting frame for CP6602/CP6902
C9900-M316 - panel mounting frame for CP6603/CP6903

Scope of supply

Scope of supply
i
Note
Once the required opening has been prepared (see section Assembly
i
Note
Wall mounting frame in a dry wall
The following components are included:
1 panel mounting frame (not
1 mounting bracket (1) and
1 fastening bracket (2) for
4 bolts M4x5 (3) for fastening
Only 3 bolts are required for mounting the CP6608 Control Panel (see top diagram).
shown),
attaching to the Control Panel,
the two brackets.
1
3
3
2
3

Mounting

Mounting of the wall mounting frame

dimensions), the mounting frame can be installed in the wall. The frame
design allows for air circulation as required.
Ensure that the wall mounting frame is oriented correctly. The pre­assembled fastening magnets must be positioned at the top of the frame (see image below).
The diagram illustrates the installation of the wall mounting frame in a dry wall.
The two pre-assembled fastening magnets are clearly visible at the top.
4 C9900 wall mounting frame

Attaching the brackets to the Control Panel

In order to be able to fasten the Control Panel in the wall mounting frame,
the fastening bracket and the mounting bracket first have to be attached to the Panel. Proceed as follows:
Attaching the fastening bracket
Warning
Attaching the mounting bracket
Remove the clamping lever located at the top in the center of the Control Panel using a
2.5 mm Alleen key. For a CP6608 Panel remove the top left or right clamping lever.
Attach the fastening bracket in place of the clamping lever using the M4 x 5 mm screw provided as shown.
Mounting - CP6608 shown as example
When removing the clamping levers prevent the Control Panel from disintegrating while the bolts are removed.
Then remove the three lower clamping levers (two levers for CP6608).
Attach the mounting bracket in place of the clamping lever using the remaining M4 x 5 mm bolts as shown.
C9900 wall mounting frame 5

Inserting the Control Panel

Once the wall mounting frame is installed in the wall and the brackets are
attached to the Control Panel, the Control Panel can be inserted in the
Position the Control Panel,
frame:
First position the Control Panel with the mounting bracket on the lower edge of the mounting frame.
Now connect all electrical connections at the rear of the Control Panel.
Warning
engage the fastening bracket
and tilt the Control Panel back
Follow the connection instructions for the respective Control Panel.
Now tilt the Control Panel back. Push the fastening bracket down slightly, so that it can engage below the upper edge of the mounting frame.
The Control Panel is now secure and cannot detach itself from the frame.
Now move the Control Panel into its final position. The Panel is now held securely in position through the pre­assembled fastening magnets.
Finally check the Control Panel for secure fastening in the frame.

Dismounting the Control Panel

Dismounting in reverse order
6 C9900 wall mounting frame
Dismounting the Control Panels occurs in reverse order:
1. Grasp carefully behind the upper edge of the Panel in order to solve the chassis of the fastening magnets.
2. Swivel out the Panel so far as the fastening bracket allows.
3. Push down the fastening bracket a bit in order to swivel out the Panel completely.
4. Disconnect all connections to the Panel.
5. Take out the Control Panel from the wall mounting frame carefully and put it down on a clean, soft base.
Assembly dimensions

Assembly dimensions

C9900-M313 Wall mounting frame for CP6601-0001 CP6901-0001
All dimensions are in mm.
front view
left view
C9900-M314 Wall mounting frame for CP6602-0001 CP6902-0001
top view
front view
left view
top view
C9900 wall mounting frame 7
Assembly dimensions
All dimensions are in mm.
C9900-M316 Wall mounting frame for CP6603-0001 CP6903-0001
C9900-M298 Wall mounting frame for CP6608-0001
front view
top view
left view
front view
top view
left view
8 C9900 wall mounting frame
Assembly dimensions
All dimensions are in mm.
C9900-M311 Wall mounting frame for CP6609-0001
C9900-M311 Wall mounting frame for CP6909-0001
front view
top view
left view
front view
top view
left view
C9900 wall mounting frame 9
Assembly dimensions

Beckhoff Support & Service

Beckhoff and their partners around the world offer comprehensive support
and service, guaranteeing fast and competent assistance with all questions related to Beckhoff products and system solutions.

Beckhoff branches and partner companies

Please contact your Beckhoff branch office or partner company for local
support and service on Beckhoff products!
The contact addresses for your country can be found in the list of Beckhoff branches and partner companies: www.beckhoff.com
You will also find further documentation

Beckhoff Headquarters

Beckhoff Automation GmbH Eiserstraße 5 33415 Verl Germany
Phone: +49(0)5246/963-0 Fax: +49(0)5246/963-198 e-mail: info@beckhoff.com

Beckhoff Support

Beckhoff offers you comprehensive technical assistance, helping you not only with the application of individual Beckhoff products, but also with wide­ranging services:
worldwide support
design, programming and commissioning of complex automation
systems
training program for Beckhoff system components
Hotline: Fax: +49(0)5246/963-9157 e-mail: support@beckhoff.com
+49(0)5246/963-157

Beckhoff Service

The Beckhoff service center supports you in all matters of after-sales service:
on-site service
repair service
spare parts service
hotline service
Hotline: Fax: +49(0)5246/963-479 e-mail: service@beckhoff.com
Quote the project number If servicing is required, please quote the project number of your product.
+49(0)5246/963-460
for Beckhoff components there.
10 C9900 wall mounting frame