Atec 6000-Plus User Manual

0 (0)
Atec 6000-Plus User Manual

USES:

Production and Compliance Testing of Appliances, Instruments and Information Technology Equipment in Accordance with UL, CSA, IEC, TUV and Other Standards such as EN60335, EN60950, EN61010, CSA C22.2 No. 1010.1, UL3111 and UL60950

Transformer Electrical Safety Testing

Electric Motor Safety Testing

Power Supply Safety Testing

Verification of the Ground Connection on Products with a Three Prong Power Cord

FEATURES:

Twin Port - Simultaneous Hipot & GB

Programmable Output Voltage to 5KV AC and 6KV DC

Ground Bond Testing to 30A AC (to 40A with Optional Transformer)

Insulation Resistance Measurements from 100kΩ to 50GΩ

Open/Short Circuit Detection Mode

Programmable Ramp, Dwell & Test Times

Storage of 100 Test Setups, 50 Steps Each

Continuous Leakage Current Monitoring

Programmable Trip Current to 40mA AC and 12mA DC

Front Panel Lockout via Password

Standard RS-232 & Remote I/O Interfaces

Optional IEEE-488, Printer Interfaces

Optional Built-in 8 Channel Scanner

Optional CaptivATE Automation Software for G6000 Plus

Guardian 6000 Plus

Electrical Safety Analyzer

with Revolutionary Twin Port Technology

Introduction

The Guardian 6000 Plus is the industry’s first safety analyzer with simultaneous Hipot and Ground Bond capability providing a dramatic savings in test time. Five instruments in one, the G6000 Plus provides AC Hipot, DC Hipot, Insulation Resistance, Ground Bond and Open/Short measurements from a single test connection. Versatile and packed with features, the G6000 Plus is a cost effective solution to the full spectrum of electrical safety compliance testing.

Description

AC Hipot: AC dielectric testing over the voltage range from 50V to 5000VAC RMS. The maximum leakage current of 40mA RMS is ideal for testing devices with high leakage currents such as power supplies which have large filter or “Y” capacitors for noise reduction.

DC Hipot: DC dielectric testing from 50V to 6000VDC with a resolution of 1V. Leakage current can be continuously monitored from 0.1µA to 12mA DC.

Insulation Resistance: The G6000 Plus is capable of measuring IR from 100k to 50GΩ with test voltage from 50V to 1000VDC in 1V steps.

Quick Discharge: In both DC and IR modes, the device under test is discharged through the HV transformer resulting in a rapid and safe discharge.

Ground Bond: With test current from 1A to 30A in 0.1A steps and programmable current limits, test time, frequency and open circuit no load voltage, the G6000 Plus provides full GB testing capability. The offset feature automatically compensates for any lead resistance. A 40A GB option is also available.

Twin Port Technology: This patented feature allows for simultaneous Ground Bond and Hipot Testing. Decrease test time and increase device through-put.

Open/Short Circuit Detection Mode: Check for Opens and Shorts against a standard capacitance value, Cs, and have confidence the DUT is properly connected.

Optional Scanners: One internal and/or multiple external scanners may be added to the G6000 Plus for testing multiple devices simultaneously. Add up to 8 HV channels or a combination of HV and GB channels.

Standard Interfaces: The Remote I/O and RS-232 interfaces provide remote control and serial data collection capability for automated applications.

For more detailed information on specifications, pricing and special purchase, rent and lease options, contact us at:

www.quadtech.com 800-253-1230

Hipot Testers • LCR Meters • Cable Testers • AC/DC Programmable Power Sources

• Megohmmeters • Milliohmmeters