Installation
Instructions
PORTSMOUTH™ |
7420.801 |
Spread Lavatory Faucet |
7420.821 |
with Speed Connect™ Drain |
Series |
Congratulations on purchasing your |
|
American Standard faucet with |
7415.801 |
Speed Connect drain, a feature found |
|
onlyon American Standard faucets. |
7415.821 |
Speed Connect Drain* |
Series |
• Fewer parts, installs in less time |
|
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
74 2 0
74 15
Certified to comply with ANSI A112.18.1
M965015 REV. 1. 7
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
Heplful tips for removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended tools
Screwdriver |
Channel Locks |
Adjustable Wrench |
Tubing Cutter |
1 |
|
|
Turn off hot and cold water |
|
INSTALL SPOUT |
CAUTION |
|
|
supplies before beginning. |
||
|
|
|
|
Insert SPOUT (1) and CABLE CONNECTOR (12) through center hole, making sure the SEAL WASHER (3) is properly seated in the SPOUT ESCUTCHEON (2).
Assemble RUBBER WASHER (4), BRASS WASHER (5) and LOCKNUT (6) onto SPOUT SHANK (7) from under side of sink . Make sure SPOUT (1) is centered in the mounting hole and the slot in the BRASS WASHER (5) faces toward the rear of the sink.
Tighten LOCKNUT (6) firmly. Fig. A.
Fig. A.
1
2
7 3
1A INSTALL VALVE BODY
Place RUBBER RING (9) into ADAPTER (10).
Install LOCKNUT (11) onto VALVE BODY (8).
From under side of mounting surface, install VALVE BODY (8) through valve mounting holes. Threads of VALVE BODY (8) should extent at least 5/16 of a inch above mounting surface top. Fig. B. Thread ADAPTER (10)
onto VALVE BODY (8) until snug against internal stop. If necessary, adjust LOCKNUT (11).
Hand tighten LOCKNUT (11) to secure VALVE BODY (8). |
1 |
Repeat above steps for opposite VALVE BODY (8A). |
SLOT
5
6
12
10
9
5/16'' MIN. |
MOUNTING |
SURFACE |
Fig. B.
10
9
8A
11 8
8 11
1
2 POP-UP DRAIN |
Fig. A. |
Fig. B. |
|
Remove CLEAR PLASTIC COVER (1). |
1 |
|
|
Remove CARDBOARD SPACER (2) from under |
3 |
DRAIN |
|
DRAIN POP-UP (3). |
|||
BODY |
|||
Tighten TAILPIECE (4) on DRAIN BODY before |
|
|
|
installing DRAIN BODY. Fig. B. |
|
|
|
|
2 |
4 |
|
|
|
3 REMOVE FLANGE |
Fig. A |
|
Fig. B. |
Thread FLANGE (1) counter-clockwise and remove |
1 |
|
|
|
|
|
|
FLANGE (1) and FOAM GASKET (2) from drain |
|
|
|
body. Fig. A. |
|
|
|
Thread LOCKNUT (3) clock-wise to bottom of |
|
|
|
drain body. Push GASKET (4) down against |
|
|
4 |
LOCKNUT (3). Fig. B. |
|
2 |
|
|
|
|
3
4 |
INSTALL DRAIN FROM |
|
REAR OF SINK |
5 TIGHTEN LOCKNUT |
BELOW FIXTURE |
|
|||
|
From under side of SINK |
4 |
|
Tighten LOCKNUT (1) firmly with Adjustable |
|
install DRAIN BODY (1) up |
|
Wrench or Channel Locks. |
|
|
through drain outlet. |
|
|
|
|
Note: No plumber’s putty |
3 |
|
|
|
or caulk is required. |
|
|
|
|
The CABLE ATTACHMENT |
|
|
|
|
POINT (2) must face towards |
|
|
|
|
the rear of the SINK. |
|
1 |
1 |
|
Install FOAM GASKET (3) and |
|
||
|
|
2 |
|
|
|
FLANGE (4) onto drain body |
|
|
|
|
from above SINK and tighten |
|
|
|
|
FLANGE (4) firmly. |
|
|
|
6 FLANGE GASKET AND POP-UP KNOB |
Fig. A. |
Fig. B. DOWN |
||
|
Check DRAIN FLANGE in SINK to ensure that |
|
1 |
|
|
|
|
||
|
WHITE FOAM GASKET (3) is fully compressed |
|
|
|
|
and not visible. Fig. A. |
|
|
|
|
POP-UP KNOB (1) must be fully down. Fig. B. |
WHITE FOAM |
|
|
|
GASKET |
|
||
|
|
|
NOT VISIBLE |
DRAIN |
|
|
|
|
FLANGE |
|
|
|
|
M965015 REV. 1. 7 |
2
7 ATTACH CABLE CONNECTOR |
Fig. A. |
Fig. B. |
Thread CABLE CONNECTOR (1) clockwise |
|
|
onto DRAIN BODY CONNECTION (2) and |
|
1 |
hand tighten. Fig. A. |
|
|
|
|
|
Your new POP-UP DRAIN installation is |
|
|
now complete. Fig. B. |
|
|
Note: Tailpeice on pop-up drain is 1-1/4” O.D. |
|
|
Fig. B. |
|
|
|
|
2 |
1-1/4” O.D.
8 CHECK OPERATION OF POP-UP |
|
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and |
1 |
closes. |
|
Note: If STOPPER (2) does not open and close properly then refer |
|
to the “troubleshooting section” of these instructions. |
|
9 MAKE WATER SUPPLY AND WASTE CONNECTIONS
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY.
Thread TEE BODY (4) to SPOUT SHANK (5).
Thread HOSE CONNECTOR (6, 6A) to VALVE CONNECTIONS (7, 7A).
Connect water supply to VALVE BODIES (1,1A) with 1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3). Use
adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing
cutter to cut to proper length.
Connect HOT water supply to inlet of left SHANK and COLD water supply to right SHANK using sealant, appropriate connectors, and COUPLING NUTS.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to |
1 |
|
|
waste outlet. |
|
7 |
|
|
|
|
|
|
1/2" PIPE THREAD |
6 |
|
|
|
2 |
WASTE |
|
|
OUTLET |
FLEXIBLE
SUPPLIES
HOT
|
5 |
1A |
|
|
|
|
|
7A |
|
|
6A |
|
|
COUPLING |
|
|
NUT |
4 |
|
3/83O.D. |
|
BULL-NOSE |
|
|
|
RISERS |
|
|
COMPRESSION |
|
|
NUT |
|
|
FERRULE |
COLD
3/8 COMPRESSION |
|
CONNECTION |
M965015 REV. 1. 7 |
|
3