Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace
Freedom 80
AUD2A040A9242A, AUD2A060A9362A, AUD2B060A9362A, AUD2B080A9362A, AUD2B080A9482A, AUD2B100A9362A, AUD2C100A9482A, AUD2C100A9602A, AUD2D100A9602A, AUD2D120A9542A, AUD2D120A9602A, AUD2D140A9602A ADD2A040A9242A, ADD2A060A9362A, ADD2B060A9362A, ADD2B080A9362A, ADD2B100A9482A, ADD2C100A9482A, ADD2C100A9602A, ADD2D120A9602A, ADD2D140A9602A
Two-Stage Fan Assisted Combustion System
PUB. NO. 12-1263-02
General
Features
Natural Gas Models
Central heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.
Safe Operation
The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety.
Quick Heating
Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure.
Burners
Multi-port In-shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas.
Integrated System Control
Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self-diag- nostics for ease of service. Also contains connection points for E.A.C./ Humidifier.
Air Delivery
The multispeed, direct drive blower motor, with sufficient airflow range for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.
Styling
Heavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass.
Features And General Operation
The FREEDOM 80 High Efficiency Gas Furnaces employ a Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access.
a.Low energy power venter.
b.Vent proving differential switch.
© 2009 American Standard Heating & Air Conditioning |
2 |
12-1263-02 |
Contents
General Features |
2 |
Features and Benefits |
|
4 |
|
|
|
Standard Equipment |
4 |
|
|
Optional Equipment |
5 |
General Data |
|
6 |
|
|
|
AUD2A040A9242A |
6 |
|
|
AUD2A060A9362A |
6 |
|
|
AUD2B060A9362A |
6 |
|
|
AUD2B080A9362A |
6 |
|
|
AUD2B080A9482A |
7 |
|
|
AUD2B100A9362A |
7 |
|
|
AUD2C100A9482A |
7 |
|
|
AUD2C100A9602A |
7 |
|
|
AUD2D100A9602A |
8 |
|
|
AUD2D120A9542A |
8 |
|
|
AUD2D120A9602A |
8 |
|
|
AUD2D140A9602A |
8 |
|
|
ADD2A040A9242A |
9 |
|
|
ADD2A060A9362A |
9 |
|
|
ADD2B060A9362A |
9 |
|
|
ADD2B080A9362A |
9 |
|
|
ADD2B100A9482A |
10 |
|
|
ADD2C100A9482A |
10 |
|
|
ADD2C100A9602A |
10 |
|
|
ADD2D120A9602A |
10 |
|
|
ADD2D140A9602A |
10 |
Performance Data |
|
11 |
|
Electrical Data |
|
14 |
|
Field Wiring |
|
16 |
|
Twinning Field Wiring |
|
18 |
|
Dimensions |
|
20 |
12-1263-02 |
3 |
Features and
Benefits
FREEDOM 80 Upflow/ Downflow Horizontal Right or Left Standard Equipment
•Convertible to horizontal with left or right airflow
•Power supply 115/1/60
•2-stage gas valve
•2-speed venter
•2 heating blower speeds
•Silicon Nitride Hot surface igniter with adaptive heat up
•Integrated solid state control with self-diagnostics
•Single wire twinning
•Inner blower door panel
•Right and left hand side knockout for venting
•Attractive color accents
•Hinged blower door
•Prefect Fit door latches
•Insulated blower door
•Gasketed blower door
•Internal filter rack
•Standard filter sizes
•Heavy gauge aluminized steel heat exchanger
•Blower door safety switch
•Multi-port In-shot burners
•Complete front service access
•Alternate bottom/ left/ right return air
•Slide out blower assembly
•Direct drive, 4-speed motors
•Adjustable fan off times
•Common vent capability
•Heavy gauge reinforced wrap-around steel cabinet
•Optional L.P. conversion kit
•Left/ right gas connection
•Accessory hook-up capability
•Selectable cooling fan off eliminates need for BAY24X045 time delay relay
•24 volt fuse
•Manual reset flame roll-out switches
4 |
12-1263-02 |
Features and
Benefits
Optional Equipment
OPTIONAL EQUIPMENT FOR CONDENSING UNITS (Check mark [ ] indicates accessories included). |
|
|
|
Comfort Control, Mechanical 2-Stage Heating/1-Stage Cooling ................................................................ |
BAYSTAT241 |
[ |
] |
Comfort Control, Heating/Cooling Single Stage (Mounts Horizontally) ............................................................ |
AY28X092 |
[ |
] |
Comfort Control, Heating/Cooling Single Stage (Mounts Vertically) .......................................................... |
BAYSTAT305 |
[ |
] |
Comfort Control, Electronic Programmable 2-Stage Heating/1-Stage Cooling ........................................ |
BAYSTAT302C |
[ |
] |
Comfort Control, Electronic Programmable 1-Stage Heating/1-Stage Cooling ........................................ |
BAYSTAT300C |
[ |
] |
Comfort Control, Electronic Non-Programmable 1-Stage Heating/1-Stage Cooling .................................. |
TAYSTAT370 |
[ |
] |
Comfort Control, Electronic Programmable (5/2) 1-Stage Heating/1-Stage Cooling .................................. |
TAYSTAT340 |
[ |
] |
Comfort Control, Heating Only .................................................................................................................. |
BAYSTAT388 |
[ |
] |
Propane Conversion Kit .......................................................................................................................... |
BAYLPKT210A |
[ |
] |
5" Media Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .......................................... |
TFM145A9FR0 [ |
] |
|
5" Media Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .......................................... |
TFM175A9FR0 [ |
] |
|
5" Media Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ................................................ |
TFM210A9FR0 [ |
] |
|
5" Media Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .......................................... |
TFM245A9FR0 [ |
] |
|
1" Media Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ................................... |
TFP145A9FR0 [ |
] |
|
1" Media Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ................................... |
TFP175A9FR0 [ |
] |
|
1" Media Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ......................................... |
TFP210A9FR0 [ |
] |
|
1" Media Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ................................... |
TFP245A9FR0 [ |
] |
|
Coil Enclosure (14-1/2" Wide Cabinets) ............................................................................................. |
BAYCLE14A1422A |
[ |
] |
Coil Enclosure (17-1/2" Wide Cabinets) ............................................................................................. |
BAYCLE17A1722A |
[ |
] |
Coil Enclosure (21" Wide Cabinets) ................................................................................................... |
BAYCLE21A2130A |
[ |
] |
Coil Enclosure (24-1/2" Wide Cabinets) ............................................................................................. |
BAYCLE24A2430A |
[ |
] |
High Altitude Switch ................................................................................................................................... |
BAYHALT239 [ |
] |
|
High Altitude Switch ................................................................................................................................... |
BAYHALT249 [ |
] |
|
Downflow Subbase .................................................................................................................................... |
BAYBASE205 |
[ |
] |
Filter Access Door Kit ................................................................................................................................ |
BAYFLTR206 [ |
] |
|
Masonry Chimney Vent Kit ...................................................................................................................... |
BAYVENT800B [ |
] |
|
Filter Rack Kit ........................................................................................................................................ |
BAYRACK960A |
[ |
] |
Cleanable Filter (14.5"/17.5" wide Upflow models) ..................................................................................... |
BAYFLTR317 [ |
] |
|
Cleanable Filter (21" wide Upflow models) ................................................................................................. |
BAYFLTR321 [ |
] |
|
Cleanable Filter (24.5" wide Upflow models) .............................................................................................. |
BAYFLTR324 [ |
] |
12-1263-02 |
5 |
General
Data
AUD2 Product Specifications 1
MODEL |
AUD2A040A9242A |
AUD2A060A9362A |
AUD2B060A9362A |
AUD2B080A9362A |
||||
RATINGS2 |
|
26000 |
|
39000 |
|
|
|
52000 |
1st Stage Input BTUH |
|
|
|
39000 |
|
|||
1st Stage Capacity BTUH (ICS)3 |
|
20800 |
|
31200 |
|
31200 |
|
41600 |
2nd Stage Input BTUH |
|
40000 |
|
60000 |
|
60000 |
|
80000 |
2nd Stage Capacity BTUH (ICS)3 |
|
32000 |
|
47000 |
|
47000 |
|
63000 |
AFUE (ICS) |
|
80.0 |
|
80.0 |
|
80.0 |
|
80.1 |
Temp. Rise (Min.-Max.) °F. |
|
30 - 60 |
|
30 - 60 |
|
30 - 60 |
|
30 - 60 |
BLOWER DRIVE |
|
DIRECT |
|
DIRECT |
|
DIRECT |
|
DIRECT |
Dia.-Width (In.) |
|
10 x 6 |
|
10 x 6** |
|
10 x 6** |
|
10 x 7 |
No. Used |
|
1 |
|
1 |
|
1 |
|
1 |
Speeds (No.) |
|
4 |
|
4 |
|
4 |
|
4 |
CFM vs. in. w.g. |
SEE FAN PERF. TABLE |
SEE FAN PERF. TABLE |
SEE FAN PERF. TABLE |
SEE FAN PERF. TABLE |
||||
Motor HP |
|
1/5 |
|
1/3 |
|
1/3 |
|
1/3 |
R.P.M. |
|
1080 |
|
1075 |
|
1075 |
|
1075 |
Volts/Ph/Hz |
|
115/1/60 |
|
115/1/60 |
|
115/1/60 |
|
115/1/60 |
COMBUSTION FAN — TYPE |
|
CENTRIFUGAL |
|
CENTRIFUGAL |
|
CENTRIFUGAL |
|
CENTRIFUGAL |
Drive - No. Speeds |
|
DIRECT - 2 |
|
DIRECT - 2 |
|
DIRECT - 2 |
|
DIRECT - 2 |
Motor HP - RPM |
|
1/100 - 2544/1374 |
|
1/100 - 2543/1727 |
|
1/100 - 2543/1727 |
|
1/100 - 2543/1727 |
Volts/Ph/Hz |
|
115/1/60 |
|
115/1/60 |
|
115/1/60 |
|
115/1/60 |
FL Amps |
|
.76/.37 |
|
.70/.40 |
|
.70/.40 |
|
.70/.40 |
FILTER — Furnished? |
|
NO |
|
NO |
|
NO |
|
NO |
Type Recommended |
|
HIGH VELOCITY |
|
HIGH VELOCITY |
|
HIGH VELOCITY |
|
HIGH VELOCITY |
Filter (No.-Size-Thk.) |
1 - 17 X 25 - 1 IN. |
1 - 17 X 25 - 1 IN. |
1 - 17 X 25 - 1 IN. |
1 - 17 X 25 - 1 IN. |
||||
VENT — Size (In.) |
|
4 ROUND |
|
4 ROUND |
|
4 ROUND |
|
4 ROUND |
HEAT EXCHANGER |
ALUMINIZED STEEL TYPE 1 |
ALUMINIZED STEEL TYPE 1 |
|
|
ALUMINIZED STEEL TYPE 1 |
|||
Type -Fired |
ALUMINIZED STEEL TYPE 1 |
|||||||
-Unfired |
|
20 |
|
20 |
|
|
|
20 |
Gauge (Fired) |
|
|
|
20 |
|
|||
ORIFICES — Main |
|
2 - 45 |
|
3 - 45 |
|
|
|
4 - 45 |
Nat. Gas. Qty. — Drill Size |
|
|
|
3 - 45 |
|
|||
L.P. Gas Qty. — Drill Size |
|
2 - 56 |
|
3 - 56 |
|
3 - 56 |
|
4 - 56 |
GAS VALVE |
REDUNDANT - TWO STAGE |
REDUNDANT - TWO STAGE |
REDUNDANT - TWO STAGE |
REDUNDANT - TWO STAGE |
||||
DIRECT IGNITION DEVICE |
|
HOT SURFACE |
|
HOT SURFACE |
|
|
|
HOT SURFACE |
Type |
|
|
|
HOT SURFACE |
|
|||
BURNERS — Type |
|
IN-SHOT |
|
IN-SHOT |
|
IN-SHOT |
|
IN-SHOT |
Number |
|
2 |
|
3 |
|
3 |
|
4 |
POWER CONN. — V/Ph/Hz4 |
|
115/1/60 |
|
115/1/60 |
|
115/1/60 |
|
115/1/60 |
Ampacity (In Amps) |
|
4.5 |
|
8.2 |
|
8.2 |
|
8.2 |
Max. Overcurrent Protection (Amps) |
|
15 |
|
15 |
|
15 |
|
15 |
PIPE CONN. SIZE (IN.) |
|
1/2 |
|
1/2 |
|
1/2 |
|
1/2 |
DUCT CONN. |
SEE |
OUTLINE DRAWING |
SEE |
OUTLINE DRAWING |
SEE |
OUTLINE DRAWING |
SEE |
OUTLINE DRAWING |
DIMENSIONS |
|
H X W X D |
|
H X W X D |
|
H X W X D |
|
H X W X D |
Crated (In.) |
41-3/4 X 16-1/2 X 30-1/2 |
41-3/4 X 16-1/2 X 30-1/2 |
41-3/4 X 19-1/2 X 30-1/2 |
41-3/4 X 19-1/2 X 30-1/2 |
||||
Uncrated |
SEE |
OUTLINE DRAWING |
SEE |
OUTLINE DRAWING |
SEE |
OUTLINE DRAWING |
SEE |
OUTLINE DRAWING |
WEIGHT |
|
119/110 |
|
127/118 |
|
|
|
142/132 |
Shipping (Lbs.)/Net (Lbs.) |
|
|
|
127/118 |
|
1 Central Furnace heating designs are certified by AGA and ETL.
2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
6 |
12-1263-02 |
General
Data
AUD2 Product Specifications 1
MODEL |
AUD2B080A9482A |
AUD2D100A9362A |
AUD2C100A9482A |
AUD2C100A9602A |
|||
RATINGS2 |
|
52000 |
|
65000 |
|
65000 |
65000 |
1st Stage Input BTUH |
|
|
|
||||
1st Stage Capacity BTUH (ICS)3 |
|
41600 |
|
52000 |
|
52000 |
52000 |
2nd Stage Input BTUH |
|
80000 |
|
100000 |
|
100000 |
100000 |
2nd Stage Capacity BTUH (ICS)3 |
|
63000 |
|
79000 |
|
79000 |
80000 |
AFUE (ICS) |
|
80.0 |
|
80.6 |
|
81.0 |
80.0 |
Temp. Rise (Min.-Max.) °F. |
|
30 - 60 |
|
40 - 70 |
|
35 - 65 |
30 - 60 |
BLOWER DRIVE |
|
DIRECT |
|
DIRECT |
|
DIRECT |
DIRECT |
Dia.-Width (In.) |
|
10 x 8 |
|
10 x 7 |
|
10 x 8 |
11 x 10 |
No. Used |
|
1 |
|
1 |
|
1 |
1 |
Speeds (No.) |
|
4 |
|
4 |
|
4 |
4 |
CFM vs. in. w.g. |
SEE FAN PERF. TABLE |
SEE FAN PERF. TABLE |
SEE FAN PERF. TABLE |
SEE FAN PERF. TABLE |
|||
Motor HP |
|
1/3 |
|
1/3 |
|
1/2 |
3/4 |
R.P.M. |
|
1075 |
|
1075 |
|
1075 |
1075 |
Volts/Ph/Hz |
|
115/1/60 |
|
115/1/60 |
|
115/1/60 |
115/1/60 |
COMBUSTION FAN — TYPE |
|
CENTRIFUGAL |
|
CENTRIFUGAL |
|
CENTRIFUGAL |
CENTRIFUGAL |
Drive - No. Speeds |
|
DIRECT - 2 |
|
DIRECT - 2 |
|
DIRECT - 2 |
DIRECT - 2 |
Motor HP - RPM |
|
1/50 - 3000 |
|
1/50 - 3000 |
|
1/50 - 3000 |
1/50 - 3000 |
Volts/Ph/Hz |
|
115/1/60 |
|
115/1/60 |
|
115/1/60 |
115/1/60 |
FL Amps |
|
1.0 |
|
0.93 |
|
0.93 |
0.93 |
FILTER — Furnished? |
|
YES |
|
YES |
|
YES |
YES |
Type Recommended |
|
HIGH VELOCITY |
|
HIGH VELOCITY |
|
HIGH VELOCITY |
HIGH VELOCITY |
Filter (No.-Size-Thk.) |
|
1 - 17 X 25 - 1 IN. |
|
1 - 17 X 25 - 1 IN. |
|
1 - 20 X 25 - 1 IN. |
1 - 20 X 25 - 1 IN. |
VENT — Size (In.) |
|
4 ROUND |
|
4 ROUND |
|
4 ROUND |
4 ROUND |
HEAT EXCHANGER |
ALUMINIZED STEEL TYPE 1 |
ALUMINIZED STEEL TYPE 1 |
ALUMINIZED STEEL TYPE 1 |
ALUMINIZED STEEL TYPE 1 |
|||
Type -Fired |
|||||||
-Unfired |
|
20 |
|
20 |
|
20 |
20 |
Gauge (Fired) |
|
|
|
||||
ORIFICES — Main |
|
4 - 45 |
|
5 - 45 |
|
5 - 45 |
5 - 45 |
Nat. Gas. Qty. — Drill Size |
|
|
|
||||
L.P. Gas Qty. — Drill Size |
|
4 - 56 |
|
5 - 56 |
|
5 - 56 |
5 - 56 |
GAS VALVE |
REDUNDANT - TWO STAGE |
REDUNDANT - TWO STAGE |
REDUNDANT - TWO STAGE |
REDUNDANT - TWO STAGE |
|||
DIRECT IGNITION DEVICE |
|
HOT SURFACE |
|
HOT SURFACE |
|
HOT SURFACE |
HOT SURFACE IGNITOR |
Type |
|
|
|
||||
BURNERS — Type |
|
IN-SHOT |
|
IN-SHOT |
|
IN-SHOT |
IN-SHOT |
Number |
|
4 |
|
5 |
|
5 |
5 |
POWER CONN. — V/Ph/Hz4 |
|
115/1/60 |
|
115/1/60 |
|
115/1/60 |
115/1/60 |
Ampacity (In Amps) |
|
8.9 |
|
8.4 |
|
11.0 |
12.8 |
Max. Overcurrent Protection (Amps) |
|
15 |
|
15 |
|
15 |
15 |
PIPE CONN. SIZE (IN.) |
|
1/2 |
|
1/2 |
|
1/2 |
1/2 |
DUCT CONN. |
SEE |
OUTLINE DRAWING |
SEE |
OUTLINE DRAWING |
SEE |
OUTLINE DRAWING |
SEE OUTLINE DRAWING |
DIMENSIONS |
|
H X W X D |
|
H X W X D |
|
H X W X D |
H X W X D |
Crated (In.) |
41-3/4 X 19-1/2 X 30-1/2 |
41-3/4 X 19-1/2 X 30-1/2 |
41-3/4 X 23 X 30-1/2 |
41-3/4 X 23 X 30-1/2 |
|||
Uncrated |
SEE |
OUTLINE DRAWING |
SEE |
OUTLINE DRAWING |
SEE |
OUTLINE DRAWING |
SEE OUTLINE DRAWING |
WEIGHT |
|
142/132 |
|
151/141 |
|
162/151 |
162/151 |
Shipping (Lbs.)/Net (Lbs.) |
|
|
|
1 Central Furnace heating designs are certified by AGA and ETL.
2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
12-1263-02 |
7 |
General
Data
AUD2 Product Specifications 1
MODEL |
AUD2C100A9612A |
AUD2D120A9542A |
AUD2D120A9602A |
AUD2D140A9602A |
RATINGS2 |
|
78000 |
78000 |
91000 |
1st Stage Input BTUH |
65000 |
|||
1st Stage Capacity BTUH (ICS)3 |
52000 |
62400 |
62400 |
72800 |
2nd Stage Input BTUH |
100000 |
120000 |
120000 |
140000 |
2nd Stage Capacity BTUH (ICS)3 |
79000 |
94000 |
95000 |
111000 |
AFUE (ICS) |
81.1 |
80.0 |
80.0 |
80.0 |
Temp. Rise (Min.-Max.) °F. |
30 - 60 |
35 - 65 |
30 - 60 |
40 - 70 |
BLOWER DRIVE |
DIRECT |
DIRECT |
DIRECT |
DIRECT |
Dia.-Width (In.) |
10 x 10 |
11 x 10 |
11 x 10 |
11 x 10 |
No. Used |
1 |
1 |
1 |
1 |
Speeds (No.) |
4 |
4 |
4 |
4 |
CFM vs. in. w.g. |
SEE FAN PERF. TABLE |
SEE FAN PERF. TABLE |
SEE FAN PERF. TABLE |
SEE FAN PERF. TABLE |
Motor HP |
3/4 |
3/4 |
3/4 |
3/4 |
R.P.M. |
1075 |
1075 |
1075 |
1075 |
Volts/Ph/Hz |
115/1/60 |
115/1/60 |
115/1/60 |
115/1/60 |
COMBUSTION FAN — TYPE |
CENTRIFUGAL |
CENTRIFUGAL |
CENTRIFUGAL |
CENTRIFUGAL |
Drive - No. Speeds |
DIRECT - 2 |
DIRECT - 2 |
DIRECT - 2 |
DIRECT - 2 |
Motor HP - RPM |
1/50 - 3000 |
1/50 - 3000 |
1/50 - 3000 |
1/50 - 3000 |
Volts/Ph/Hz |
115/1/60 |
115/1/60 |
115/1/60 |
115/1/60 |
FL Amps |
0.93 |
.95 |
.95 |
.95 |
FILTER — Furnished? |
YES |
YES |
YES |
YES |
Type Recommended |
HIGH VELOCITY |
HIGH VELOCITY |
HIGH VELOCITY |
HIGH VELOCITY |
Filter (No.-Size-Thk.) |
1 - 24 X 25 - 1 IN. |
1 - 20 X 25 - 1 IN. |
1 - 24 X 25 - 1 IN. |
1 - 24 X 25 - 1 IN. |
VENT — Size (In.) |
4 ROUND |
4 ROUND |
4 ROUND |
4 ROUND |
HEAT EXCHANGER |
|
ALUMINIZED STEEL TYPE 1 |
ALUMINIZED STEEL TYPE 1 |
ALUMINIZED STEEL TYPE 1 |
Type -Fired |
ALUMINIZED STEEL TYPE 1 |
|||
-Unfired |
|
20 |
20 |
20 |
Gauge (Fired) |
20 |
|||
ORIFICES — Main |
|
6 - 45 |
6 - 45 |
7 - 45 |
Nat. Gas. Qty. — Drill Size |
5 - 45 |
|||
L.P. Gas Qty. — Drill Size |
5 - 56 |
6 - 56 |
6 - 56 |
7 - 56 |
GAS VALVE |
REDUNDANT - TWO STAGE |
REDUNDANT - TWO STAGE |
REDUNDANT - TWO STAGE |
REDUNDANT - TWO STAGE |
DIRECT IGNITION DEVICE |
|
HOT SURFACE |
HOT SURFACE |
HOT SURFACE |
Type |
HOT SURFACE |
|||
BURNERS — Type |
IN-SHOT |
IN-SHOT |
IN-SHOT |
IN-SHOT |
Number |
5 |
6 |
6 |
7 |
POWER CONN. — V/Ph/Hz4 |
115/1/60 |
115/1/60 |
115/1/60 |
115/1/60 |
Ampacity (In Amps) |
12.8 |
12.8 |
12.8 |
13.0 |
Max. Overcurrent Protection (Amps) |
15 |
15 |
15 |
15 |
PIPE CONN. SIZE (IN.) |
1/2 |
1/2 |
1/2 |
1/2 |
DUCT CONN. |
SEE OUTLINE DRAWING |
SEE OUTLINE DRAWING |
SEE OUTLINE DRAWING |
SEE OUTLINE DRAWING |
DIMENSIONS |
H X W X D |
H X W X D |
H X W X D |
H X W X D |
Crated (In.) |
41-3/4 X 26-1/2 X 30-1/2 |
41-3/4 X 23 X 30-1/2 |
41-3/4 X 26-1/2 X 30-1/2 |
41-3/4 X 26-1/2 X 30-1/2 |
Uncrated |
SEE OUTLINE DRAWING |
SEE OUTLINE DRAWING |
SEE OUTLINE DRAWING |
SEE OUTLINE DRAWING |
WEIGHT |
|
176/165 |
186/174 |
193/181 |
Shipping (Lbs.)/Net (Lbs.) |
175/163 |
1 Central Furnace heating designs are certified by AGA and ETL.
2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
8 |
12-1263-02 |