Installation
Instructions
7411.702
7411.712
Centerset Lavatory Faucet with 7411.722
EverClean™ Finish & SpeedConnect™ Drain
7411.732
Congratulations on purchasing your American Standard faucet with EverClean finish and SpeedConnect drain, two features found only on American Standard faucets.
EverClean Finish |
SpeedConnect Drain* |
•One wipe effortlessly removes spots
•Eliminates the need for cleaners and scrubbing
•Permanent surface protectant remains beautiful for the life of the faucet
•EverClean™ available on: Polished Chrome, Satin Nickel,
Stainless Steel, Polished Brass (or any combination of these finishes)
Certified to comply with ANSI A112.18.1
US60402 Rev. 1 . 1
*Your new American Standard faucet is designed to work only with the SpeedConnect drain. Heplful tips for removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Required tools
Screwdriver Channel Locks Adjustable Wrench Tubing Cutter
1 |
|
|
Turn off hot and cold water |
|
INSTALL FAUCET |
CAUTION |
|||
|
supplies before beginning. |
Turn off hot and cold water supplies before beginning.
Insert FAUCET (1) and CABLE CONNECTOR (2) through mounting holes of Sink or mounting surface. Fig. A.
Assemble LOCKNUTS (3) onto SHANKS (4) from under |
Fig. A. |
side of Sink. Hand tighten firmly. Fig. B. |
|
(HAND TIGHTEN) |
|
3
POP-UP
CABLE
4 |
4 |
Fig. B.
SINK OR
MOUNTING
SURFACE
3
2 |
2 |
1
2 POP-UP DRAIN
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3).
Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig. B.
Fig. A. |
Fig. B. |
1 |
|
3 |
DRAIN |
BODY |
|
2 |
4 |
|
3 REMOVE FLANGE
Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3). Fig. B.
Fig. A. |
Fig. B. |
1
4
2
3
4 |
INSTALL DRAIN FROM |
BELOW FIXTURE |
From under side of SINK install DRAIN BODY (1) up through drain outlet.
Note: No plumber’s putty or caulk is required.
The CABLE ATTACHMENT POINT (2) must face towards the rear of the SINK.
Install FOAM GASKET (3) and FLANGE (4) onto drain body from above SINK and tighten FLANGE (4) firmly.
REAR OF SINK |
5 TIGHTEN LOCKNUT |
|
Tighten LOCKNUT (1) firmly with Adjustable |
4 |
Wrench or Channel Locks. |
|
|
3 |
|
1 |
1 |
2 |
|
6 |
FLANGE GASKET AND POP-UP KNOB |
Fig. A. |
Fig. B. DOWN |
|
|||
|
Check DRAIN FLANGE in SINK to ensure that |
|
1 |
|
WHITE FOAM GASKET (3) is fully compressed |
|
|
|
and not visible. Fig. A. |
|
|
|
POP-UP KNOB (1) must be fully down. Fig. B. |
WHITE FOAM |
|
|
|
GASKET |
DRAIN |
|
|
NOT VISIBLE |
FLANGE |
US60402 Rev. 1 . 1
2