AEG RH430LD, RH440LD, RH456LD, RH455LD, RH440LDG Manual

...
0 (0)
AEG RH430LD, RH440LD, RH456LD, RH455LD, RH440LDG Manual

INSTRUCTION for USE

ABSORPTION-REFRIGERATOR

miniBar

RH 430 LD RH 438 LD RH 440 LD RH 441 LD RH 448 LD RH 460 LD RH 461 LD RH 468 LD

English

Type H20 / 60 821 2693 - 61

RH 436 D

RH 438 D

RH 447 D

RH 448 D

RH 468 D

RH 455 LD RH 456 LD RH 456 LDE

T.D. 12/2003

TABLE OF CONTENTS

Model No.

Product No.

Serial No.

1.0

INTRODUCTION

3

2.0

FOR YOUR SAFETY

3

 

2.1

Warnings and Safety Advice

3

 

2.2

Coolants

3

3.0

WARRANTY AND

3

 

CUSTOMER SERVICE

 

4.0

INSTALLATION

4

 

4.1

The Purpose of this Manual

4

 

4.2

Tools/Materials Required

4

 

4.3

Unpacking

4

 

4.4

Cleaning

4

 

4.5

Installation

5

 

4.6

Securing

6

 

4.7

Connecting the Device to the

7

 

 

Electricity Supply

 

 

4.8

Changing the Sliding Hinge

8

 

4.9

Changing the Doorhang

9

5.0

INSTRUCTION FOR USE

10

 

5.1

Initial Operation

10

 

5.2

Temperature Control

10

 

5.3

Automatic Defrost Function

10

 

5.4

Leakage Detection

10

 

5.5

Automatic Door Control (ADC)

11

 

5.6

Interior Light

12

 

5.7

Environmental Advice

13

 

5.8

Disposal

13

 

5.9

Energy Saving Tips

13

 

5.10

Declaration

13

 

5.11

Check List

14

 

5.12

Technical Data

15

 

 

 

 

Information

Attention

Environmental

Warning

Advice

 

These operating instructions should be kept in a safe place.

If this device is passed on, please include these operating instructions with it.

2

1.0INTRODUCTION

You have made an excellent choice by choosing the Dometic miniBar.

We are convinced that you will be satisfied with your new appliance in every way. Silent in operation, the miniBar fulfils high quality standards and guarantees

an efficient use of resources and energy during its entire working life, i.e. during manufacturing, use and disposal.

Please study the installation and operating instructions carefully before attempting to operate the miniBar.

2.0FOR YOUR SAFETY

2.1Warnings and Safety Advice

In the interests of children's safety:

When disposing of the refrigerator, remove all doors and leave the shelves inside. This prevents children from being accidentally trapped or suffocated in the refrigerator.

Never open the cooling unit - it is under high pressure.

Never store explosive substances, such as lighter fuel, petrol, ether or similar products in the miniBar.

The minibar is not suitable for the proper storage of medications.

The miniBar must be installed in such a way that accidental contact with the cooling unit (which heats up when in use) is impossible.

The appliance has to be connected to a properly earthed socket in line with the relevant valid country regulations.

Servicing must only be carried out by authorised service personnel.

2.2Coolants

Ammonia is used as a coolant.

This is a natural compound also used in household cleaning agents (1 litre of Salmiak cleaner contains up to 200g of ammonia - about twice as much as is used in the refrigerator). Sodium chromate is used for corrosion protection (less than 2% of the coolant).

If a leak occurs (which can be easily detected due to the unpleasant smell):

Switch the device off (pull mains plug, if applicable);

Ventilate room thoroughly.

Inform hotel personnel.

For the safety of hotel guests and personnel, it has been established by inspectors that the coolant poses no threat to health.

3.0WARRANTY AND CUSTOMER SERVICE

Warranty arrangements are in accordance with EC Directive 44/1999/CE and the normal conditions applicable for the country concerned.

For warranty or other servicing, please contact our Dometic Service department. Any damage due to improper use is not covered by the warranty. The warranty does not cover any modifications to the appliance or the use of non-original Dometic parts; the warranty does not apply if the installation and operating instructions are not adhered to and no liability shall be entertained. Parts can be ordered throughout Europe from our Dometic Service department.

When contacting customer service, please always state model, product, MLC-Code and serial number! You can find this information on the model label inside the device. e.g.

3

4.0INSTALLATION

4.1The Purpose of this Manual

The manual shows you how to:

install the miniBar correctly.

operate the miniBar correctly.

guarantee the miniBar´s correct maintenance and functioning.

deal with faults by yourself.

4.2Tools / Materials Required

You will need the following tools for initial operation:

mild detergent

4.3Unpacking

Check during unpacking that the device is defect-free.

Report transport damage to the transport company within 48 hours.

Check that the voltage noted on the model label corresponds to the mains voltage.

Depending on the model, the following parts can be found in the miniBar :

2x

4.4Cleaning

Before operating the miniBar, we recommend you clean it both inside and outside.

Use a soft cloth, lukewarm water and a mild detergent.

Following this, wash out the miniBar using clean water and dry thoroughly.

At annual intervals, remove dust from fridge aggregate using a brush or soft cloth.

ATTENTION

To prevent material damage:

Do not use soap or detergents which are harsh, coarse or which contain soda.

Keep the door seal free from oil and grease.

The cylinder locks have been lubricated in the factory to be long-lasting.

4

4.5Installation

200 cm²

20 mm

IMPORTANT:

Please follow the installation details below carefully. Guarantee is valid for products installed as described only.

1.The refrigerator must be level both directions

2.There sould be 20mm clearance to the wall

3.Ventilation must be provided as shown in alternatives A,B,C or D

4.The ventilation duct must at least measure 105mm x the wtdth of the refrigerator

5.Only the entire cooling unit must project into the duct as shown

6Air passing through the duct must not be preheated by any source of heat

7.Ventilation grills, if used, must have openings of at least 200cm² each

Where a socket outlet is used for the mains connection lead, the outlet must be freely accessible.