3COM 2226 PLUS User Manual

www.3com.com
Baseline Switch 2226 Plus
User Guide
Installationsanleitung
Part No. 10015240 Rev. AA Published August 2006
3Com Corporation • 350 Campus Drive • Marlborough • MA USA 01752-3064
Copyright © 2006, 3Com Corporation. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.
3Com Corporation provides this documentation without warranty, term, or condition of any kind, either implied or expressed, including, but not limited to, the implied warranties, terms or conditions of merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.
If there is any software on removable media described in this documentation, it is furnished under a license agreement included with the product as a separate document, in the hard copy documentation, or on the removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy, please contact 3Com and a copy will be provided to you.
UNITED STATES GOVERNMENT LEGEND
If you are a United States government agency, then this documentation and the software described herein are provided to you subject to the following:
All technical data and computer software are commercial in nature and developed solely at private expense. Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995) or as a “commercial item” as defined in FAR such rights as are provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited rights only as provided in DFAR
252.227-7015 (Nov applicable. You agree not to remove or deface any portion of any legend provided on any licensed program or documentation contained in, or delivered to you in conjunction with, this User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not be registered in other countries.
1995) or FAR 52.227-14 (June 1987), whichever is
2.101(a) and as such is provided with only
3Com, 3Com Express, 3Com Guardian and the 3Com logo are registered trademarks of 3Com
Corporation.
IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Inc. Intel is a registered trademark of Intel Windows, and Windows NT are registered trademarks of Microsoft Xerox is a registered trademark of Xerox Corporation. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company, Ltd.
Corporation.
Corporation.
All other company and product names may be trademarks of the respective companies with which they are associated.
ENVIRONMENTAL STATEMENT
It is the policy of 3Com Corporation to be environmentally-friendly in all operations. To uphold our policy, we are committed to:
Establishing environmental performance standards that comply with national
legislation and regulations.
Conserving energy, materials and natural resources in all operations.
Reducing the waste generated by all operations. Ensuring that all waste
conforms to recognized environmental standards. Maximizing the recyclable and reusable content of all products.
Ensuring that all products can be recycled, reused and disposed of safely.
Ensuring that all products are labelled according to recognized
environmental standards.
Improving our environmental record on a continual basis.
End of Life Statement
3Com processes allow for the recovery, reclamation and safe disposal of all end-of-life electronic components.
Regulated Materials Statement
3Com products do not contain any hazardous or ozone-depleting material.
Environmental Statement about the Documentation
The documentation for this product is printed on paper that comes from sustainable, managed forests; it is fully biodegradable and recyclable, and is completely chlorine-free. The varnish is environmentally-friendly, and the inks are vegetable-based with a low heavy-metal content.

CONTENTS

ABOUT THIS GUIDE
Conventions 7 Documentation Comments 8 Product Registration 8
1 INTRODUCING THE BASELINE SWITCH
Overview of the Baseline Switch 9 Features and Capabilities 9
Autosensing of MDI/MDIX Connections 9 Autonegotiating 10/100 Mbps Ports 9 Gigabit Combo Ports (RJ-45/SFP) 9
Physical Features 10
Front Panel 10 Rear Panel 13
Package Contents 14
2 INSTALLING THE SWITCH
Before You Begin 15 Positioning the Switch 15 Rack-Mounting or Free-Standing 16
Using the Mounting Kit 16 Montagesatz Anweisungen 17 Placing Units On Top of Each Other 17
Supplying Power to the Switch 18
Checking for Correct Operation 18
Using SFP Tranceivers 19
Approved SFP Transceivers 19 Inserting an SFP Transceiver 19 Removing an SFP Transceiver 20
Performing Spot Checks 21
3 CONNECTING TO THE WEB INTERFACE
Requirements for Accessing the Web Interface 23 Running the Discovery Application 23 Logging On to the Web Interface 25 Navigating the Web Interface 26
Menu 26 Buttons 29 Port Status 29
Accessing the Interface Without Using Discovery 30
DHCP Assigned IP Address 30 Manually Assigned (Static) IP Address 30
4 CONFIGURING THE SWITCH
Configuration Overview 31 Device Summary Information 31 Administration Settings 33
Modifying the IP Address Settings 33 Automatic IP Configuration 33
IP Setup 34 Backup Configuration 35 Restore Configuration 35 Firmware Upgrade 36 Initialize 37 Reboot 37 System Access 38 System Time 40 SNMP 40
Configuring VLANs 42
VLAN 43 Forwarding Tagged/Untagged Frames 47 Sample VLAN Configurations 47 Spanning Tree 49 IGMP Snooping 51 IGMP Query 51 Broadcast Storm 51
Configuring Port Settings 53
Administration 53 Speed/Duplex for 1000 Mbps Connections 55 Link Aggregation 56 Spanning Tree per Port 58 Port Mirroring 61
Statistics 62 QoS VoIP Traffic Settings 62 Security 65
RADIUS Client 65
802.1X Settings 67
Monitoring 70
Address Table 70
Cable Diagnostics 70
5 TROUBLESHOOTING
Resetting to Factory Defaults 73 Forgotten Password 74 Forgotten Static IP Address 74 Solving LED Issues 74 If the Problem Persists 76
A OBTAINING SUPPORT FOR YOUR PRODUCT
Register Your Product 77 Purchase Value-Added Services 77 Troubleshoot Online 77 Access Software Downloads 77 Telephone Technical Support and Repair 78 Contact Us 78
B TECHNICAL INFORMATION
Related Standards 81
Environmental 81 Physical 81 Electrical 81
C SAFETY INFORMATION
Important Safety Information 83
GLOSSARY
REGULATORY NOTICES
INDEX

ABOUT THIS GUIDE

This guide describes how to install your 3Com Switch and perform initial management configurations.
This guide is intended for use by those responsible for installing and setting up network equipment; consequently, it assumes a basic working knowledge of LANs (Local Area Networks).
Diese Anleitung ist fur die Benutzung durch Netzwerkadministratoren vorgesehen, die fur die Installation und das einstellen von Netzwerkkomponenten verantwortlich sind; sie setzt Erfahrung bei der Arbeit mit LANs (Local Area Networks) voraus.
If release notes are shipped with your product and the information there differs from the information in this guide, follow the instructions in the release notes.
Most user guides and release notes are available in Adobe Acrobat Reader Portable Document Format (PDF) or HTML on the 3Com World Wide Web site:
www.3com.com

Conventions

Ta bl e 1 and Table 2 list conventions that are used throughout this guide.
Ta bl e 1 Notice Icons
Icon Notice Type Description
Information note Information that describes
Caution Information that alerts you to
Warning Information that alerts you to
important features or instructions
potential loss of data or potential damage to an application, system, or device
potential personal injury
8 ABOUT THIS GUIDE
Ta bl e 2 Text Conventions
Convention Description
The words “enter” and “type”
Keyboard key names If you must press two or more keys
Words in italics Italics are used to:
When you see the word “enter” in this guide, you must type something, and then press Return or Enter. Do not press Return or Enter when an instruction simply says “type.”
simultaneously, the key names are linked with a plus sign (+). Example:
Press Ctrl+Alt+Del
Emphasize a point.
Denote a new term at the place where it
is defined in the text.
Identify menu names, menu commands,
and software button names. Examples: From the Help menu, select Contents. Click OK.

Documentation Comments

Your suggestions are very important to us. They will help make our documentation more useful to you. Please e-mail comments about this document to 3Com at:
pddtechpubs_comments@3com.com
Please include the following information when contacting us:
Document title
Document part number (on the title page)
Page number (if appropriate)
Example:
Baseline Switch 2226 Plus User Guide
Part number: 10015240
Page 25
Please note that we can only respond to comments and questions about 3Com product documentation at this e-mail address. Questions related to technical support or sales should be directed in the first instance to your network supplier.

Product Registration

You can now register your Baseline Switch on the 3Com Web site to receive up-to-date information on your product:
http://esupport.3com.com
1

INTRODUCING THE BASELINE SWITCH

This chapter provides an overview of the features and capabilities of the 3Com Baseline Switch 2226 Plus. It also identifies the contents of the Switch package and helps you get to know the physical features of the device.

Overview of the Baseline Switch

The 3Com® Baseline Switch 2226 Plus is a versatile, easy-to-use unmanaged switch. It is ideal for users who want the high-speed performance of 10/100 switching with the added functionality of Gigabit fiber links, but do not need sophisticated management capabilities. The Switch is shipped ready for use. No configuration is necessary.

Features and Capabilities

The Switch has 24 shielded RJ-45, 10/100 Mbps auto-negotiating ports and 2 Gigabit combo ports (which comprised of a RJ-45 port and a Small Form Factor Pluggable (SFP) transceiver slot) on the front panel for easy, flexible connection to fiber-based Gigabit media.

Autosensing of MDI/MDIX Connections

All ports on the Switch can autosense both medium dependent interface (MDI) and medium dependent interface crossover (MDIX) connections. This allows you to connect network devices to each port using either a normal straight-through TP (twisted pair) cable or a ‘crossover’ TP cable.
Any port can therefore be used to connect to another switch port, server, or workstation without additional configuration.

Autonegotiating 10/100 Mbps Ports

Each 10/100 Mbps port automatically determines the speed and duplex mode of the connected equipment and provides a suitable switched connection. The 10/100 Mbps ports can operate in either half-duplex or full-duplex mode.

Gigabit Combo Ports (RJ-45/SFP)

The 2 Gigabit combo ports support fiber Gigabit Ethernet short-wave (SX) and long-wave (LX) SFP transceivers in any combination. This offers you the flexibility of using SFP transceivers to provide connectivity between the Switch and a 1000 Mbps core network.
10 INTRODUCING THE BASELINE SWITCH
When an SFP port is in operation, the corresponding 1000BASE-T port is disabled. The 1000 Mbps connections can only operate in full duplex mode.

Physical Features

Figure 1 shows the front and rear panels of the Switch. The numbers in this diagram refer to numbered sections in
“Front Panel” on page 10 and “Rear Panel” on
page 13.
Figure 1 Front and Rear Panels

Front Panel

The front panel of the Switch contains a series of indicator lights (LEDs) that help describe the state of various networking and connection operations.
(1) RJ-45 10/100 Ports
WARNING: RJ-45 Ports. These are shielded RJ-45 data sockets. They cannot be used as standard traditional telephone sockets, or to connect the unit to a
traditional PBX or public telephone network. Only connect RJ-45 data connectors, network telephony systems, or network telephones to these sockets. Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data sockets.
AVERTISSEMENT: Points d’accès RJ-45. Ceux-ci sont protégés par des prises de données. Ils ne peuvent pas être utilisés comme prises de téléphone conventionnelles standard, ni pour la connection de l’unité à un réseau téléphonique central privé ou public. Raccorder seulement connecteurs de données RJ-45, systèmes de réseaux de téléphonie ou téléphones de réseaux à ces prises. Il est possible de raccorder des câbles protégés ou non protégés avec des jacks protégés ou non protégés à ces prises de données.
WARNHINWEIS: RJ-45-Porte. Diese Porte sind geschützte Datensteckdosen. Sie dürfen weder wie normale traditionelle Telefonsteckdosen noch für die Verbindung der Einheit mit einem traditionellem privatem oder öffentlichem Telefonnetzwerk gebraucht werden. Nur RJ-45-Datenanscluße, Telefonnetzsysteme or Netztelefone an diese Steckdosen anschließen. Entweder geschützte oder ungeschützte Buchsen dürfen an diese Datensteckdosen angeschlossen werden.
The Switch has 24 10/100 Mbps auto-negotiating ports. Each port supports automatic MDI/MDI-X detection and
Physical Features 11
can be connected to either a 10BASE-T, or 100BASE-TX device.
For each port, the speed and duplex mode (half duplex or full duplex for 10BASE-T and 100BASE-TX) are automatically determined by the capabilities of the connected device.
CAUTION: The Switch supports full duplex auto-negotiation. If auto-negotiation is disabled for 1000BASE-T, then the Switch uses the forced-mode default of 100 full duplex mode. If the connected device does not support auto-negotiation, the Switch will operate in half duplex mode (even if the attached device is operating in full duplex mode). In such a configuration, you may notice some degradation of network performance. 3Com recommends that you use devices that are capable of auto-negotiation (and that you ensure that auto-negotiation is enabled, if it is a configurable option).
(2) Gigabit Combo Ports (RJ-45/SFP)
The Gigabit combo ports (RJ-45/Small Form Factor Pluggable (SFP) ports) are numbered 25 and 26. If the link connections on the SFP ports are active, the associated RJ-45 port of the same number is disabled.
The two SFP ports support fiber Gigabit Ethernet short-wave (SX) and long-wave (LX) SFP transceivers in any combination. This offers you the flexibility of using SFP transceivers to provide connectivity between the Switch and remote 1000 Mbps workgroups or to create
a high-capacity aggregated link backbone connection. The default active port is the SFP port. The selection of active ports can be configured via the Web interface.
The SFP port supports full duplex mode only.
SFP ports are numbered 25 and 26 on the Switch. When an SFP port is active it has priority over the 10/100/1000 port of the same number. The corresponding 10/100/1000 port is disabled when an SFP link connection is active.
(3) Link/Activity Status LEDs
The first (top) and third row of LEDs, which are colored yellow or green, show the link, activity and speed status of the related ports:
10/100/1000BASE-T Ports
Status Meaning
Green The link is operating at 1000 Mbps.
Ye ll ow The link is operating at 10 or 100 Mbps.
Flashing Green
Flashing Ye ll ow
Packets are being received or transmitted on the port at 1000 Mbps.
Packets are being received or transmitted on the port at 10 or 100 Mbps.
12 INTRODUCING THE BASELINE SWITCH
Off The link has not been established, either nothing
is connected to the port, or there is a problem:
Check that the attached device is powered
on.
Check that the cable or fiber is the correct
type and is not faulty.
For fiber connections, ensure that the receive
(RX) and transmit (TX) cable connectors are not swapped.
If these checks do not identify the cause of the problem, it may be that the unit or the device connected to the port is faulty. Contact your supplier for further advice.
10/100BASE-TX Ports
Status Meaning
Green The link is operating at 100 Mbps.
Yellow The link is operating at 10 Mbps.
Flashing Green
Flashing Yellow
Packets are being received or transmitted on the port at 100 Mbps.
Packets are being received or transmitted on the port at 10 Mbps.
Off The link has not been established, either nothing
is connected to the port, or there is a problem:
Check that the attached device is powered
on.
Check that the cable or fiber is the correct
type and is not faulty.
For fiber connections, ensure that the receive
(RX) and transmit (TX) cable connectors are not swapped.
If these checks do not identify the cause of the problem, it may be that the unit or the device connected to the port is faulty. Contact your supplier for further advice.
(4) Duplex Status LEDs
The second and fourth (bottom) row of Status LEDs, which are colored yellow (for duplex) or green (for module active), show the duplex status of the related ports:
10/100/1000BASE-T Ports
Status Meaning
Yellow The port is operating in full duplex mode.
Off The port is operating in half duplex mode.
1000BASE-T only operates in full duplex mode. 10/100BASE-TX can be in half or full duplex mode.
Physical Features 13
Gigabit Combo Ports
Status Meaning
Green SFP is inserted in the slot.
Off No SFP in the slot.
(5) Power LED
The Power LED shows the power status of the Switch.
Status Meaning
Green The unit is powered on and ready for use.
Yel lo w Internal power, POST, or loopback test has
Off The unit is not receiving power.
failed. Switch is in fail-safe mode.
Check that the power cord is connected cor-
rectly.
If the unit still does not operate, contact your
supplier.
(6) Self-adhesive Pads
The unit is supplied with four self-adhesive rubber pads.
Do not apply the pads if you intend to rack mount the unit.
If the unit is to be part of a free-standing stack, apply the pads to each marked corner area on the underside of the unit. Place the unit on top of the lower unit, ensuring that the pads locate with the recesses of the lower unit.

Rear Panel

The rear panel of the Switch contains a power supply socket and a recovery button.
(7) Power Supply
The Switch automatically adjusts to the supply voltage. Only use the power cord that is supplied with the unit.
(8) Recovery Button
The recovery button reinitializes the Switch. This returns the Switch to the factory default settings if, for example, you have forgotten the default IP address, or forgotten your user name or password.
CAUTION: 3Com recommends that you back up your configuration settings before you recover the Switch, otherwise your configuration may be lost. Refer to “Resetting to Factory Defaults” on page 73 for details.
14 INTRODUCING THE BASELINE SWITCH

Package Contents

Before installing and using the Switch, verify that your Switch package is complete. The Switch comes with:
One power cord
Four standard height, self-adhesive rubber pads
One mounting kit
Installation CD
This User Guide
Warranty flyer
The Switch is powered from the AC supply.
If any of the above items are damaged or missing, contact your 3Com network supplier immediately.
2

INSTALLING THE SWITCH

This chapter contains information that you need to install and set up the Switch. It covers the following topics:
Before You Begin
Positioning the Switch
Rack-Mounting or Free-Standing
Supplying Power to the Switch
Using SFP Transceivers
Performing Spot Checks

Before You Begin

WARNING: Safety Information. Before installing or removing any components from the Switch or carrying out any maintenance procedures, read the safety information provided in
AVERTISSEMENT: Consignes de Sécurité. Avant d'installer ou d'enlever tout composant du Switch ou d'entamer une procédure de maintenance, lisez les informations relatives à la sécurité qui se trouvent dans l'Appendice C (
Appendix C) de ce guide.
Appendix C of this guide.
WARNHINWEIS: Sicherheitsinformationen. Bevor Sie Komponenten aus dem Switch entfernen oder dem Switch hinzufuegen oder Instandhaltungsarbeiten verrichten, lesen Sie die Sicherheitsanweisungen, die in Anhang C ( aufgefuehrt sind.
ADVERTENCIA: Información de Seguridad. Antes de instalar o extraer cualquier componente del product o de realizar tareas de mantenimiento, debe leer la información de seguridad facilitada en el Apéndice C (
Appendix C) de esta guía del usuario.
AVVERTENZA: Informazioni di Sicurezza. Prima di installare o rimuovere qualsiasi componente dal product o di eseguire qualsiasi procedura di manutenzione, leggere le informazioni di sicurezza riportate nell'Appendice C ( l'utente.
Appendix C) in diesem Handbuch
Appendix C) della presente guida per

Positioning the Switch

The Switch is suitable for use in an office environment where it can be free-standing or mounted in a standard 19-inch equipment rack.
16 INSTALLING THE SWITCH
Alternatively, the Switch can be rack-mounted in a wiring closet or equipment room. A mounting kit, containing two mounting brackets and four screws, is supplied with the Switch.
When deciding where to position the Switch, ensure that:
It is accessible and cables can be connected easily.
Cabling is away from sources of electrical noise.
These include lift shafts, microwave ovens, and air conditioning units. Electromagnetic fields can interfere with the signals on copper cabling and introduce errors, therefore slowing down your network.
Water or moisture cannot enter the case of the unit.
Air flow around the unit and through the vents on
the side of the case is not restricted (3Com recommends that you provide a minimum of 25 (1
in.) clearance).
The air is as free from dust as possible.
Temperature operating limits are not likely to be
exceeded. It is recommended that the unit is installed in a clean, air conditioned environment.
mm

Rack-Mounting or Free-Standing

The unit can be mounted in a 19-inch equipment rack using the mounting kit or it can be free standing. Do not place objects on top of the unit or stack.
CAUTION: If installing the Switch in a free-standing stack of different size Baseline or Superstack 3 units, the smaller units must be installed above the larger ones. Do not have a free-standing stack of more than six units.

Using the Mounting Kit

The Switch is supplied with two mounting brackets and four screws. These are used for rack mounting the unit. When mounting the unit, you should take note of the guidelines given in page 15.
The Switch is 1U (1.7 inches) high and will fit in a standard 19-inch rack.
CAUTION: Disconnect all cables from the unit before continuing. Remove the self-adhesive pads from the underside of unit, if already fitted.
“Positioning the Switch” on
It is always good practice to wear an anti-static wrist strap when installing network equipment, connected to a ground point. If one is not available, try to keep in contact with a grounded rack and avoid touching the unit's ports and connectors, if possible. Static discharge can cause reliability problems in your equipment.
To rack-mount the Switch:
1 Place the unit the right way up on a hard, flat surface
with the front facing towards you.
2 Locate a mounting bracket over the mounting holes on
one side of the unit.
Rack-Mounting or Free-Standing 17
3 Insert the two screws supplied in the mounting kit and
fully tighten with a suitable screwdriver.
Figure 2 Rack Mounting the Unit
4 Repeat steps 2 and 3 for the other side of the unit.
5 Insert the unit into the 19-inch rack and secure with
suitable screws (not provided).
6 Reconnect the cables.

Montagesatz Anweisungen

Der Switch wird mit zwei Halterungen und vier Schrauben geliefert. Diese werde für den Einbau in einen Baugruppenträger benutzt. Bei der Montage der Baugruppe beachten Sie die Anweisungen aus “Positioning the Switch” on page 15.
Der Switch ist eine Baueinheit hoch und passt in einen Standard 19'' (Zoll) Baugruppenträger.
ACHTUNG: Entfernen Sie alle Kabel, bevor Sie fortfahren. Entfernen Sie die selbstklebenden Polster (Füße) von der Unterseite der Baugruppe, falls diese bereits angebracht sind.
1 Plazieren Sie die Baugruppe aufrecht auf einer harten,
ebenen Fläche mit der Vorderseite zu Ihnen.
2 Ordnen Sie eine der Halterungen über den Löchern an
der Seite der Baugruppe an.
3 Stecken Sie zwei der mitgelieferten Schrauben in die
Löcher und drehen Sie diese mit einem geeigneten Schraubendreher fest.
4 Widerholen Sie letzten beiden Schritte auf der anderen
Seite der Baugruppe.
5 Führen Sie die Baugruppe in den 19" (Zoll)
Baugruppenträger ein und sichern sie die Baugruppe mit geeigneten Schrauben. (Nicht im Lieferumfang enthalten).
6 Schließen Sie alle Kabel wieder an.

Placing Units On Top of Each Other

If the Switch units are free-standing, up to six units can be placed one on top of the other. If you are mixing a variety of Baseline and SuperStack units, the smaller units must be positioned at the top.
18 INSTALLING THE SWITCH
If you are placing Switch units one on top of the other, you must use the self-adhesive rubber pads supplied. Apply the pads to the underside of each Switch, sticking one in the marked area at each corner.
Place the Switch units on top of each other, ensuring that the pads of the upper unit line up with the recesses of the lower unit.

Supplying Power to the Switch

Power problems can be the cause of serious failures and downtime in your network. Ensure that the power input to your system is clean and free from sags and surges to avoid unforeseen network outages. 3Com recommends that you install power conditioning, especially in areas prone to blackout, power dips and electrical storms.
The unit is intended to be grounded. Ensure it is connected to earth ground during normal use. Installing proper grounding helps to avoid damage from lightning and power surges.
Before powering on the Switch, verify that the network cables and the power cable are securely connected.
CAUTION: The Switch has no ON/OFF switch. The only way to power on and power off the Switch is by connecting and disconnecting the power cord. This is called “power cycling”.
To power on the Switch:
1 Plug the power cord into the power socket on the rear
panel of the Switch. Refer to
“(7) Power Supply” on
page 13 for more information.
2 Plug the other end of the power cord into a power
outlet.
When the Switch is powered on, the Power LED lights up. If the Power LED does not light up, refer to
“(5)
Power LED” on page 13 for more information.

Checking for Correct Operation

After you power on the Switch, it automatically performs a power-on self-test (POST). During POST, the Power LED on the front panel of the Switch flashes green.
When POST is complete, the Power LED turns green. If the Power LED turns yellow after POST, it means that POST failed and the Switch has entered fail-safe mode.
The following summarizes the possible colors for the Power LED after POST.
Status Meaning
Green The unit is powered on and ready to use.
Yellow Power-on self-test or loopback test failed. The
Switch is in fail-safe mode. This can happen if a port or ports fail when the Switch was powered on.
Using SFP Tranceivers 19
Off The unit is not receiving power:
Verify that the power cord is connected cor-
rectly, and then try powering on the Switch again
If the Switch still does not operate, contact
your 3Com network supplier
If POST fails, try the following:
Power off the Switch, and then power it on again.
Check the Power LED and see if POST was successfully completed.
Reset the Switch. See “Resetting to Factory Defaults”
on page 73.
CAUTION: Resetting the Switch to its factory defaults erases all your settings. You will need to reconfigure the Switch after you reset it.
If these do not resolve the issue:
Check the 3Com Knowledgebase for a solution. To
visit the 3Com Knowledgebase Web site, start your Web browser, and then enter
http://knowledgebase.3com.com.
Contact your 3Com network supplier for assistance.

Using SFP Tranceivers

The following sections describe how to insert an SFP transceiver into an SFP slot.
SFP transceivers are hot-insertable and hot-swappable. You can remove them from and insert them into any SFP port without having to power down the Switch.

Approved SFP Transceivers

The following list of approved SFP transceivers is correct at the time of publication:
3CSFP91 SFP (SX)
3CSFP92 SFP (LX)
To access the latest list of approved SFP transceivers for the Switch on the 3Com Web site, enter this URL into your Internet browser:
http://www.3com.com
3Com recommends using 3Com SFPs on the Switch. If you insert an SFP transceiver that is not supported, the Switch will not recognize it.

Inserting an SFP Transceiver

To be recognized as valid, the SFP transceiver must have the following characteristics:
1000BASE-SX or 1000BASE-LX media type:
1000BASE-SX SFP transceiver
Use this transceiver to connect the Switch directly to a multimode fiber-optic cable.
20 INSTALLING THE SWITCH
1000BASE-LX SFP transceiver
Use this transceiver to connect the Switch directly to a single mode fiber-optic cable or to multi mode fiber using a conditioned launch cable.
If the SFP transceiver is faulty, it will not operate within the Switch. See “Troubleshooting” on page 73.
To activate the SFP port:
1 Hold the transceiver so that the fiber connector is
toward you and the product label is visible, as shown in Figure 3. Ensure the wire release lever is closed (in the upright position).
Figure 3 Inserting an SFP Transceiver
2 Gently slide the transceiver into the SFP slot until it
clicks into place.
-
CAUTION: SFP transceivers are keyed and can be properly inserted only one way. If the transceiver does not click when you insert it, remove it, turn it over, and reinsert it.
3 Remove the plastic protective cover, if fitted.
4 Connect the fiber cable.
5 Attach a male duplex LC connector on the network
cable into the duplex LC connector on the transceiver.
6 Connect the other end of the cable to a device fitted
with an appropriate Gigabit Ethernet connection.
7 Check the Module Active LEDs on the front of the
Switch to ensure that the SFP transceiver is operating correctly.

Removing an SFP Transceiver

Removing an SFP transceiver does not require powering off the Switch.
To remove an SFP transceiver:
1 Disconnect the cable from the transceiver.
2 Move the wire release lever downwards until it is
pointing toward you.
3 Pull the wire release lever toward you to release the
catch mechanism.
The SFP transceiver should slide out easily.

Performing Spot Checks

At frequent intervals, you should visually check the Switch. Regular checks can give you an early warning of a possible failure; any problems can then be attended to when there will be least effect on users.
3Com recommends periodically checking the items listed in
Ta bl e 1.
Ta bl e 1 Items to Check
Performing Spot Checks 21
Cabling Check that all external cabling connections
Cooling fan Where possible, check that the cooling fan
are secure and that no cables are pulled taut.
is operating by listening to the unit. The fan is fitted near to the front right hand side of the unit (when viewed from the front).
If you experience any problems operating the Switch, refer to
“Troubleshooting” on page 73.
22 INSTALLING THE SWITCH
3

CONNECTING TO THE WEB INTERFACE

The Switch has a built-in Web interface that you can use to set the admin password, change the IP address that is assigned to the Switch, and configure its advanced settings.
If you only want the Switch to function as a basic layer 2 switch, you do not need to access the Web interface and configure the Switch.
This chapter provides information on how the gain access to the Web interface using the Dis covery application. It also introduces the menu items and buttons that are available on the Web interface.
The following topics are covered:
Requirements for Accessing the Web
Interface
Running the Discovery Application
Logging On to the Web Interface
Navigating the Web Interface
Accessing the Interface Without Using
Discovery

Requirements for Accessing the Web Interface

To connect to the Web interface, you need the following:
The Discovery application, which is included
-
on 3Com Baseline Switch 2226 Plus CD-ROM that is supplied with your Switch
A computer that is connected to the Switch
and that has a Web browser

Running the Discovery Application

The 3Com Baseline Switch 2226 Plus CD-ROM contains, among others, the Discovery application.
24 CHAPTER 3: CONNECTING TO THE WEB INTERFACE
The Discovery application can be used for detecting and connecting to the Switch on the network. The application will launch a Web interface that provides the user with options to configure, modify, and upgrade the Switch.
To use Discovery to connect to the Web interface, do the following:
1 On a computer that is connected to the Switch,
insert the CD-ROM into its CD drive.
Discovery should start automatically. If it does not start automatically, go to the
\Discovery
folder on the CD-ROM, and then double-click
discovery.exe.
The Welcome screen of Discovery appears.
Figure 4 Welcome Screen of Discovery
2 If the computer has multiple network adapters,
select the adapter that connects the computer to the Switch, and then click Next.
If the computer has only one adapter, click Next.
Discovery searches the network for 3Com devices. When detection is complete, the Discovered Devices screen displays detected network devices.
Logging On to the Web Interface 25
Figure 5 Discovered Devices Screen
3 On the Discovered Devices screen, click
Baseline Switch 2226 Plus, and then click Next.
The Completing the 3Com Discovery Application screen appears.
4 Click Finish.
The logon dialog box for the Web interface appears.

Logging On to the Web Interface

After the Web interface loads in your Web browser, the first page that appears is the logon screen. On this screen, you need to enter the administration user name and password to gain access to the Web interface.
The logon screen also displays the IP address that the Switch is currently using.
Figure 6 Logon Dialog Box
To log on to the Web interface:
1 In User name, type admin.
2 Leave the Password field blank.
3 Click OK.
26 CHAPTER 3: CONNECTING TO THE WEB INTERFACE

Navigating the Web Interface

The Web interface has been designed to enable you to easily perform advanced configuration tasks and view information about the Switch.

Menu

The menu is located on the left side of the Web interface. When you click an item on the menu, the related screen appears in the main part of the interface. Some menu items will give you sub-menu tabs to choose from.
Figure 7 Switch Screen Layout
Sub-Menu Tabs
Menu
System Information
Navigating the Web Interface 27
Ta bl e 1 lists the available items on the menu.
Ta bl e 1 Available Menu Items
Menu Item Description
Device Summary Contains tabs that allow you to:
Provide a summary of the Switch’s
basic settings and versions of current components.
Set the polling interval in seconds.
Display the description for each
color coded port.
Save Configuration Saves the Switch’s configuration.
Administration Manages the device.
IP Setup Allows you to setup, modify, or view
Backup Configuration
Restore Configuration
Firmware Upgrade Allows you to upgrade the current
Initialize Allows you to reset the Switch to
Reboot Allows you to perform system reboot.
the IP configuration parameters.
Allows you to backup the Switch’s configuration.
Allows you to restore a saved configuration.
firmware via HTTP.
factory default settings.
Menu Item Description
System Access Contains tabs that allow you to:
Display user summary information.
Create a new user.
Modify existing users.
Remove existing users.
System Time Allows you to set the system time.
SNMP Contains tabs that allow you to:
Display SNMP summary.
Add community strings.
Remove community strings.
Device Configures the device.
VLAN Contains tabs that allow you to:
Create a VLAN.
Modify a VLAN.
Modify VLAN membership for a
port.
Rename a VLAN.
Remove a VLAN.
Display VLAN membership for a
port.
Display VLAN information.
Spanning Tree Allows you to configure a Spanning
Tree Protocol.
28 CHAPTER 3: CONNECTING TO THE WEB INTERFACE
Menu Item Description
IGMP Snooping Allows you to enable or disable IGMP
snooping.
IGMP Query Allows you to enable or disable IGMP
query mode.
Broadcast Storm Allows you to enable or disable rate
limiting.
Port Configures the ports.
Administration Contains tabs that allow you to:
Display selected port information for
the entire Switch.
Display individual port information.
Modify the port settings.
Link Aggregation Contains tabs that allow you to:
Display link aggregation summary.
Create an aggregation group.
Modify the port memberships.
Remove an aggregation group.
Spanning Tree per Port
Contains tabs that allow you to:
Display selected spanning tree
information for every port.
Display individual port spanning tree
information.
Modify the spanning tree settings
for a port.
Menu Item Description
Port Mirroring Monitor traffic going in and out of
ports.
Statistics Display statistics for a selected port.
QoS Configures QoS settings.
VoIP Traffic Setting Contains tabs that allow you to:
Display Voice VLAN summary.
Configure Voice VLAN global
settings.
Configure Voice VLAN port settings.
Display port information for Voice
VLAN and Trunk details.
Display OUI summary.
Add or remove OUI.
Security Configures security settings.
Radius Client Contains tabs that allow you to:
Display Radius Client information.
Configure Radius Client settings and
set authentication parameters.
Navigating the Web Interface 29
Menu Item Description
802.1X Settings Contains tabs that allow you to:
Display system authentication
summary.
Display detailed information per
port.
Configure system authentication
settings.
Monitoring Display Switch monitoring information.
Address Table Displays MAC address table
information for ports and VLANs.
Cable Diagnostics Contains tabs that allow you to:
Display selected cable diagnostics
information for all ports.
Display all cable diagnostics
information for a single port.
Help Displays 3Com contact information
and describes how to use the online help system.
Log Out Allows you to securely log off the Web
interface.

Buttons

Depending on the screen that is currently displayed, the following buttons may appear:
Apply – Click to save and apply any changes
that you have made
Cancel – Click to discard any unsaved
changes
Help – Click to display the context-sensitive
help information for the screen that is currently displayed. The help pages provide information on the tasks that you can perform on each screen.

Port Status

There is an image of the Switch’s front panel in the Device View page, which indicates ports that are currently in use.
To configure a port, click the port on the image for the these following configuration options:
View detailed port information
Configure the port settings
View port statistics
Loading...
+ 65 hidden pages