ZyXEL Communications ES-2048, ES-2024A, ES-2024PWR User Manual

0 (0)

ZyXEL ES-2000 Series

(ES-2024A / ES-2024PWR / ES-2048)

Ethernet Switch

Support Notes

Version 3.60

September 2006

ES-2000 Series Switch Support Notes

INDEX

How to manage & maintain your Switch?

Firmware Upgrade

Restore a Configuration File

Backing Up a Configuration File

Load Factory Defaults

Physical Switch connection

Connecting two switches via Fiber Channel

General Networking

DHCP option 82 (Relay Agent Information Option)

Separating a physical network into many virtual networks

Introduction to Virtual LAN

Port Based Virtual LAN

Setting up Port Based VLAN

IEEE 802.1Q Tag-based VLAN

Setting up Tag-based VLAN

IP Multicasting

IGMP Snooping

To ring a network by building reducdent links and connections between Switch

Introduction to Spanning Tree Protocol How does Spanning Tree Protocol Work?

Switching security

MAC freeze

Centralized Management

Introduction of SNMPc and NetAtlas *NetAtlas v1.02 supports ES-2024A

*NetAtlas v1.03 supports ES-2048 / ES-2024PWR Cluster Management -- iStacking

FAQ

What is the default setting of the IP parameters?

What is the default login Name and Password of the Web Configuration?

How to access the Switch through the console port?

What is default login password of the console, telnet, and FTP? How to change the password?

How to access the Command Line Interface?

If I forgot the Switch password, how can I reset the password to default?

How do I configure an IP address?

Is Online Help available on the Web GUI?

2

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

How to restart device from Web?

How to check the current running firmware version? Is the mini GBIC transceiver hot-swappable?

What are the differences between ES-2024 and ES-2024A? How much PoE Power can ES-2024PWR supply concurrently?

Remaining:

Some demonstration in this support note may not use the exact model that you are using. However, their functions and settings work the same way.

How to manage & maintain your Switch?

Firmware Upgrade

From Web GUI:

1.Download (and unzipped) the correct model firmware to your computer.

2.Click Management and then Maintenance in the navigator panel to bring up the following screen.

3.Click on the “Click Here” link of the Firmware Upgrade to bring up the following screen.

3

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

4.Browse the firmware located or type in the path into the “File Path” field.

5.Click on the Upgrade button.

From Console Port:

1.Download (and unzipped) the correct model firmware to your computer.

2.Connect to the console port and open the Terminal Emulation Software.

3.Restarting the switch to enter the debug mode via the terminal.

4.Enter “ATUR”.

5.Use X-modem protocol to transfer (Send File) the firmware.

6.Enter “ATGO” to restart the switch after done uploading the firmware.

From Command Line FTP:

1.Download (and unzipped) the correct model firmware to your computer.

2.Launch the FTP client on your PC to login to Switch. (From the command prompt, type “ftp <Switch IP>”

3.Press “Enter” for the User name

4.Enter password to get the ftp prompt.

5.Enter “bin” to set transfer mode to binary.

6.Use “put” to transfer the firmware from the computer to the switch, for example: “put firmware.bin ras” transfers the firmware on your computer (firmware.bin) to the switch and renames it “ras”.

7.Enter “quit” to exit the ftp prompt.

4

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

5

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

Restore a Configuration File

From Web GUI:

1.Click Management and then Maintenance in the navigator panel to bring up the following screen.

2.Click on the “Click Here” link of the Restore Configuration to bring up the following screen.

3.Browse to locate the file with the file name or type in the path and the file name into the “File Path” field.

4.Click on the Restore button.

From Console Port:

1.Connect to the console port and open the Terminal Emulation Software.

6

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

2.Restarting the Switch to enter the debug mode via the terminal.

3.Enter “ATLC”

4.Use X-modem protocol to transfer (Send File) the firmware.

5.Enter “ATGO” to restart the Switch after done uploading the configuration file.

From Command Line FTP:

1.Download (and unzipped) the correct model firmware to your computer.

2.Launch the FTP client on your PC to login to Switch. (From the command prompt, type “ftp <Switch IP>”.

3.Press “Enter” for the User name

4.Enter password to get the ftp prompt.

5.Enter “bin” to set transfer mode to binary.

6.Use “put” to transfer the the configuration file from the computer to the switch, for example: “put comfig.rom rom-0” transfers the firmware on your computer (config.rom) to the switch and renames it “rom-0”.

7.Enter “quit” to exit the ftp prompt.

7

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

Backing Up a Configuration File

From Web GUI:

1.Click Management and then Maintenance in the navigator panel to bring up the following screen.

2.Click on the “Click Here” link of the Backup Configuration to bring up the following screen.

3.Click on the “Backup” button to bring up the File Download dialog. Then, clicking on the Save button to backup the configuration rom file to a proper location.

From Console Port:

1.Connect to the console port and open the Terminal Emulation Software.

2.Restarting the Switch to enter the debug mode via the terminal.

3.Enter “ATTD”

8

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

4.Use X-modem protocol to transfer (Receive File) the firmware.

5.Enter “ATGO” to restart the Switch after done uploading the configuration file.

From Command Line FTP:

1.Download (and unzipped) the correct model firmware to your computer.

2.Launch the FTP client on your PC to login Switch. (From the command prompt, type “ftp <Switch IP>”

3.Press “Enter” for the User name

4.Enter password to get the ftp prompt.

5.Enter “bin” to set transfer mode to binary.

6.Use “get” to transfer the firmware from the computer to the switch, for example: “get rom-0 config.rom” transfers the firmware on your computer (config.rom) to the switch and renames it “config.rom”.

7.Enter “quit” to exit the ftp prompt.

9

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

Load Factory Defaults

From Web GUI:

1.Click Management and then Maintenance in the navigator panel to bring up the following screen.

2.Click on the “Click Here” button of the Load Factory Defaults to bring up the following screen.

3.A dialog pops up with the message “Are you sure you want to load factory defaults?”.

4.Click OK to go to the following dialog.

5.Click on the OK button. Now, all switch configurations has been reset to the factory defaults and the system will be restarted.

6.Please note that the switch IP address is now 192.168.1.1.

From Console Port:

1.Connect to the console port and open the Terminal Emulation Software.

2.Type in the correct password to bring up the prompt. Type “erase run” to load the factory default configurations.

10

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

Physical Switch connection

How to connect two switches via Fiber Channel

Your Switch may come with one or many mini-GB ports. ZyXEL offers Small Form-factor Pluggable (SFP) transceivers for Gigabit Ethernet and Fiber Channel applications. These small, modular optical interface transceivers offer a convenient and cost effective solution for the adoption of Gigabit Ethernet and Fiber Channel in data center, campus, metropolitan area access, ring networks, and storage area networks. It supports full duplex Gigabit speeds and hot-pluggable feature.

Scenario

In this scenario, ES-2108-LC is connected to GS-4024 via the mini-GB Port with a LC/LC Fiber cable (62.5/125MM). PC “Alpha” is connected to ES-2108-LC and another PC “Delta” is connected to the GS-4024 Switch via the RJ45 Port.

What you need here to complete this scenario:

11

All contents copyright (c) 2006 ZyXEL Communications Corporation.

 

 

ES-2000 Series Switch Support Notes

z

ZyXEL Switch with Mini-GB port

x2

 

 

(note: ES-2024A / ES-2024PWR / ES-2048 comes with 2 Mini-GB

 

Port)

 

 

 

 

z

SFP-SX Transceiver

x2

z

LC/LC Fiber Cable (62.5/125MM)

x1

 

 

Here is the photo of the SFP-SX Transceiver & the LC/LC Fiber Cable.

Steps to complete this scenario

1. First, pick up your ES-2108-LC and GS-4024Switch and power them up.

12

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

Photo of the ES-2108-LC Switch

2. Find both Mini-GB Port on ES-2108-LC and GS-4024.

3. Get one transceiver and plug it into the Mini-GB Port of ES-2108-LC

13

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

4. Plug another transceiver into the Mini-GB Port of GS-4024 Switch

14

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

5. Remove both side of the protection cap from the LC/LC Fiber Cable.

6.Plug the LC/LC Fiber Cable into the transceivers on both ES-2108-LC and GS-4024 Switch.

If you connected the cable correctly, the LED of the “LINK” will light up.

15

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

7.Now, connect the first PC “Alpha” to ES-2108-LC and the second PC “Delta” to the GS-4024 via the regular Ethernet cable.

8.Set the NICs in both computers to the same IP Domain.

(ex, PC “Alpha” :192.168.1.4/24; PC “Delta” : 192.168.1.5/24) 9. From PC “Alpha”, PING PC “Delta” at 192.168.1.5

10.From PC “Delta”, PING PC” Alpha” at 192.168.1.4

11.Now you can confirm that the network connection between ES-2108-LC and GS-4024 is up and running.

16

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

General Networking

DHCP Relay Option 82 Application

This feature is only available on ES-2048

ISP may want to limit the number of IP address or deliver some specific IP addresses according to certain Switch port, VLAN ID and option 82 string. They can easily to achieve this with DHCP Relay Option 82 feature and a DHCP server supporting Option 82 function.

Network

DHCP

Server 192.168.1.99

Ethernet Port

Port 25

DHCP Client

17

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

How to set up DHCP Relay Option 82 Environment

Here, we will set up an environment to allow a PC to get DHCP IP address in specific IP pool according to its Switch port, VLAN ID and the option 82 string. In this case, we are using GS-3012 for the demonstration. PC is behind 25th Switch port and the option 82 string is a string “GS-3012”. We use the IP Commander as DHCP server. Its IP is 192.168.1.99 and the IP pool is between 192.168.1.201 and 192.168.1.203 for VID=1, Switch port=25 and the option 82 string is “GS-3012”.

1. Switch (GS-3012) settings

Click IP Application, DHCP Relay in the navigation panel to display configuration screen as shown. You will see the DHCP Relay setup page. Active the DHCP relay and Option 82 function. Also, click Information to make “GS-3012” as the Option 82 string. Information is READ ONLY here and it is the same as the host name of the Switch.

Now we can connect PC to the 25th SWITCH port. Please see former applications for detailed settings.

3. IP Commander settings

Open IP Commander. Right click “IP commander and then click “connect new

18

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

server”.

Input the DHCP IP address or domain name and click “ok”. Our IP is 192.168.1.99.

19

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

Input user name and password. The default user name is “administrator” and password is “incognito”.

20

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

It will bring up the following screen, please make sure that your DHCP is in

online” status. Then click “wizard” in the top tool bars and select “rule wizard”.

21

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

Give a name and description to the new rule.

22

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

Assign a range of IP addresses or just one IP address to this rule. In our case, we set the IP pool from 192.168.1.201 to 192.168.1.203.

After input IP pool, we select “DHCP Option” in Keywords combobox.

23

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

After select the “DHCP Option”, it will pop up “Add DHCP Option Rule” dialog. Select “option 82 Relay Agent Information”, sub-option 1, binary data. For port 25, VLAN 1, “GS-3012”, please key in “0019000147532d33303132” as the key value and click OK. Please note that the first 2 bytes define port number, the second 2 bytes is VLAN ID and the other bytes are the Option 82 string.

24

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

After you finish above step, you will see the following figure.

25

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ES-2000 Series Switch Support Notes

Then pop up the following screen and you can just press Next button.

Then you can add DHCP template (option) such as gateway, DNS server and so on.

26

All contents copyright (c) 2006 ZyXEL Communications Corporation.

ZyXEL Communications ES-2048, ES-2024A, ES-2024PWR User Manual

ES-2000 Series Switch Support Notes

Here we use “192.168.1.1” as gateway IP address of DHCP client PC.

27

All contents copyright (c) 2006 ZyXEL Communications Corporation.

Loading...
+ 61 hidden pages