Zircon SL-AC User Manual

StudSensor™Pro SL-AC Stud Finder
with AC WireWarning™and
SpotLite®Pointing System
The Zircon StudSensor™Pro detects wood and metal studs and joists in walls,floors, and ceilings.It features two scanning modes,recessed LEDs, a durable high-impact case,and the patented SpotLite
®
Pointing System. It also has WireWarning to continuously detect hot AC voltage in both modes.
INSTALLING THE BATTERY
Squeeze sides of
1
clip to help
release clip end.
Slide 9-V battery
2
into compartment, terminal side first, matching (+) and (–) terminals from battery to case.
Replace the clip.
3
Battery will last
approximately two years under normal conditions.
CALIBRATION AND SCANNING IN STUD SCAN OR DEEPSCAN®MODES
Note: Unit calibrates on each use. Use Stud Scan Mode for depths to about 3⁄4in.
(19 mm) and DeepScan for depths up to
1
⁄2in. (38 mm) or double layers.
1 Note: Keep unit flat against wall. Do not lift or tilt
unit during calibration or scanning.
Slide the Mode Selector
4
switch to the desired scanning mode.The mode can be selected with the unit on or off.
With StudSensor Pro
5
turned off,position the unit
flat against the wall.
Without moving unit, squeeze
6
and hold On/Off button.
®
LED should be lit.
TruCal
Continue to hold
7
in the On/Off button then slowly slide unit horizontally across the wall,right or left.
As you begin to approach a stud, the red LEDs
8
will light successively,from bottom to top.
SL-AC
SL-AC
Stud Edge Groove
AC WireWarning
On/Off Button
StudScan
Mode LED
When the top green
9
LED is lit, a steady
tone sounds,and the
®
shines,you
SpotLite have located the edge of
SpotLite
®
DEEPSCAN
the stud. Mark this spot.
Continue scanning
10
beyond marked spot until green LED goes out. Slide unit in reverse direction to locate other edge of stud.
Mark this second
11
spot. Middle of stud is centered between the two marks.
CONTINUOUS AC VOLTAGE DETECTION (WireWarning™)
The StudSensor Pro
12
SL-AC
detects from 90 to 250 V at 50 to 60 Hz AC in a hot electrical wire. The voltage detection feature works continuously in both Stud Scan and DeepScan modes.When sensing voltage,the small AC light comes on.
Caution: The StudSensor Pro SL-AC will not detect hot wires inside metal pipe or conduit, behind metallic wall covering, or behind some plywood or other dense materials. Use extra caution in these situations. Always turn the power off when nailing, cutting, or drilling near electrical wires.
OPERATING CAUTIONS
Depending on the proximity of electrical wiring
13
or pipes to the wall surface,the scanner may detect them in the same manner as studs.Caution should always be used when nailing,cutting, or drilling in walls,floors,and ceilings that may contain these items.
To avoid surprises,remember that studs or joists are normally spaced 16 in. (406 mm) or 24 in. (610 mm) apart and are 1 closer together or a different width may not be a stud, joist, or firebreak.Always turn off the power when working near electrical wires.
1
⁄2in. (38 mm) in width. Anything
®
Pointing System
®
TruCal LED
Stud DeepScan Mode LED
Mode Switch
WORKING WITH DIFFERENT MATERIALS
StudSensor Pro SL-AC
1
1
⁄2in. (38 mm) of common construction materials in DeepScan mode,three pri-
mary factors can affect sensing depth: thickness,density,and moisture content. StudSensor Pro
•Bare wood flooring (in DeepScan mode)
•Linoleum on wood base
•Gypsum drywall over plywood sheathing
•Wallpapered walls (if dry)
•Textured ceilings if uniform thickness (Place a thin piece of cardboard on ceiling and scan through it to avoid damage to texturing.)
StudSensor Pro such as:
•Ceramic floor tile
•Carpeting and padding
®
•Wallpaper with metallic fibers
•Freshly painted walls that are still damp (must dry at least a week)
• Lath and plaster walls
•Foil covered insulation board
FCC Part 15 Class B Registration Warning
This equipment has been tested and found to comply with the limits for a Class B digital device,pur­suant to Part 15 of FCC Rules.These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,may cause harmful interference to radio communications.However,there is no guar­antee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be deter­mined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
(1)Reorient or relocate the receiving antenna. (2)Increase the separation between the equipment and receiver. (3)Connect the equipment into an outlet on a circuit,
(4)Consult the dealer or an experienced radio/TV
SL-AC
can scan through up to
different from that which the receiver is connected (if applicable).
technician for help.
is for use on dry,interior walls only.Although StudSensor Pro
SL-AC
can scan effectively through most sheet materials,including:
SL-AC
is not designed to scan materials with inconsistent density
HELPFUL HINTS
Situation
Lights start flashing and unit starts beeping.
Center green LED doesn’t light in Stud Scan mode.
The green TruCal LED lights but, when scan­ning, unit doesn't do anything else.
All three red LEDs and green LED light at the same time and unit beeps continuously.
Working in DeepScan mode and can’t detect studs.
Detects other objects besides studs.
You suspect electrical wires,but do not detect any.
Area of voltage detection is too large.
Questions? Check our Web site at www.zircon.com and click “Support.”
Probable Causes
• Scan began on dense part of wall or over a stud.
• Unit not flat against wall.
• Unit tilted or lifted during scan. (All these factors affect proper calibration.)
•Wall is particularly thick or dense.
• Unit may not be flat against the wall.
• If it is in the DeepScan mode (the DeepScan LED is lit),you may have calibrated over a stud.
• Scanning surface is too dense or too wet for unit to operate.
•You may have calibrated over a stud. (The error condition is disabled in DeepScan mode because it is twice as sensitive as Stud Scan.)
•You may be holding the unit like a TV remote,aiming it at the wall.
• Electrical wiring and metal or plastic pipes may be near or touching back surface of wall.
• Wires may be shielded behind metallic wall coverings, plywood shearwall or other dense material, or in conduit; StudSensor Pro SL-AC may not be able to find them.
•The wires may not be hot.
•Wires may be too deep to sense.
• Static charge may develop on drywall,spreading voltage detection as much as 12 in. (305 mm) from each side of an actual electrical wire.
•Turn unit off,move over a few inches, press On/Off button,
Solutions
and start again.
• On rough surfaces,place piece of paper on wall,scanning through it to help slide unit more smoothly.
•Keep hand at least 6 in.(152 mm) from StudSensor Pro
SL-AC
while you calibrate and scan. Hold unit with thumb and index finger no higher than handgrips.Be careful not to move your fingers after calibration.
• Always hold unit parallel to and move perpendicular to object you’re trying to locate.
• Interpret red LED closest to center as stud edge.
• Switch to DeepScan to locate the stud.
• Hold unit so two Velcro contact with wall.
• Recalibrate unit in a different place and rescan area.
• If you are using unit on a recently taped,painted, or wallpapered wall,allow time to dry and try again.
• Move StudSensor Pro and recalibrate.
• Hold unit so two Velcro contact with wall.
• Remember that studs or joists are normally spaced 16 in. (406 mm) or 24 in. (610 mm) apart and are 11⁄2in. (38 mm) wide.
• Always turn off power when cutting,nailing,or drilling near electrical wires.
• See above solution.
• Use extra caution if the area has plywood,thick wood backing behind drywall,or thicker-than-normal walls.
• If a switch controls an outlet,make sure it is ON for detection, but turned off when working near electrical wires.
•To narrow detection,turn unit off and on again at the edge of where wire was detected and scan again.
strips on the back make
SL-AC
over a few inches
strips on the back make