S E R V I C E |
Whirlpool Europe |
Customer Services |
ART 839-2/G
Service Manual
Freestanding Cooling
Combi
ART 839-2/G
Model |
ART 839-2/G |
|
Version |
8564 839 10012 |
Page |
|
Technical data |
2 |
|
Spare part list |
3 |
|
Exploded view |
4 |
|
Circuit and Wiring diagram |
5 - 6 |
This documentation is only intended for qualified technicians who are aware of the respec-
tive safety regulations. |
|
Date: 22.07.1998 |
Subject to modification |
Document-No.: 4812 711 19788 |
|
22.07.1998 / Page 2 |
ART 839-2/G |
Whirlpool Europe |
|
S E R V I C E |
Doc. No: 4812 711 19788 |
8564 839 10012 |
Customer Service |
||
|
|
|
|
|
Technical data
Dimensions |
|
|
Height |
202 |
cm |
Width |
59.2 |
cm |
Depth |
61.5 |
cm |
Capacity |
|
|
Total |
|
|
gross |
388 |
l |
net |
366 |
l |
Cooling |
|
|
gross |
267 |
l |
net |
266 |
l |
Freezing |
|
|
gross |
121 |
l |
net |
100 |
l |
Electrical connection |
|
|
Voltage |
220 - 240 V |
|
Frequency |
50 |
Hz |
Power consumption |
|
|
in 24 hours |
1.63 |
kWh |
Freezing capacity |
|
|
in 24 hours |
15 |
kg |
Compressor (cooling) |
|
|
Type |
EMS 36 HLP |
|
Capacity (CECOMAF) |
77 |
W |
Compressor (freezing) |
|
|
Type |
GL 60 AA |
|
Capacity (CECOMAF) |
108 |
W |
Refrigerant (cooling) |
|
|
Type |
R 134 a |
|
Quantity |
50 |
g |
Refrigerant (freezing) |
|
|
Type |
R 134 a |
|
Quantity |
80 |
g |
Thermostat switching value (cooling) |
||
Switch on temperature |
|
|
min. |
+ 4.5 |
˚C |
Switch on temperature |
|
|
max. |
+ 4.5 |
˚C |
Switch off temperature |
|
|
min. |
- 13 |
˚C |
Switch off temperature |
|
|
max. |
- 26 |
˚C |
Thermostat switching value (freezing) |
||
Switch on temperature |
|
|
min. |
- 17 |
˚C |
Switch on temperature |
|
|
max. |
- 24.5 |
˚C |
Switch off temperature |
|
|
min. |
- 22.5 |
˚C |
Switch off temperature |
|
|
max. |
- 30 |
˚C |