Whirlpool AMB 953 Service Manual

SERVICE
Model AMB 953 Version 8528 953 10000 Page
Whirlpool Europe Customer Services
AMB 953
Service Manual
Air Conditioning Split AMB 953
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respec­tive safety regulations. Date: 08.11.2004 (Mod. 01) Subject to modification Document-No.: 4812 731 19854
28.06.2004 / Page 2 AMB 953 Whirlpool Europe Doc. No: 4812 731 19854 8528 953 10000 Customer Service
SERVICE
Technical data
Operation type
Cooling / Heating
Dimensions
Indoor-unit
Height 270 mm Width 800 mm Depth 168 mm
Outdoor-unit
Height 530 mm Width 755 mm Depth 252 mm
Weight
Indoor-unit 8.5 kg / net Outdoor-unit 34 kg / net
Compressor
Type Toshiba, PA 108 X 1C - 4 FZ
Refrigerant
Type R 410 a Quantity 1140 g
Cooling Capacity
2637 Watt 9000 BTU/h
Heating Capacity
3076,5 Watt 10500 BTU/h
Airflow / Evaporator Airvolume
420 m3 /h
Electrical connection
Voltage 220 - 240 V Frequency 50 Hz
Power Supply
Cooling
Input 820 W
3.8 A
Heating
Input 850 W
3.8 A
Dehumidifying Capacity
0.9 l/h
Working temp. range
Indoor + 18.0 / + 32.0˚C Outdoor - 5.0 / + 43.0˚C
Noise level
Indoor-unit 27 - 33 dB Outdoor-unit 50 dB