SERVICE
Model AMB 897
Version 8528 897 10000 Page
Whirlpool Europe
Customer Services
AMB 897
Service Manual
Air Conditioner
Split Type
AMB 897
Technical data 2
Spare part list 3
Exploded view 4
Circuit and Wiring diagram 5
This documentation is only intended for qualified technicians who are aware of the respective safety regulations.
Date: 22.11.2002 Subject to modification
Document-No.: 4812 731 13791
22.11.2002 / Page 2 AMB 897 Whirlpool Europe
Doc. No: 4812 731 13791 8528 897 10000 Customer Service
Technical data
SERVICE
Operation type
Cooling / Heating
Dimensions
Indoor - unit
Height 1080 mm
Width 330 mm
Depth 210 mm
Outdoor - unit
Height 957 mm
Width 793 mm
Depth 362 mm
Weight
Indoor - unit 16 kg / net
Outdoor - unit 78 kg / net
Electrical connection
Voltage 220 V
Frequency 50 Hz
Rated Current (Cooling) 13.8 A
Rated Current (Heating) 15.3 A
Compressor (cooling)
Type ZR34K3-PFJ
Refrigerant
Type R 22
Quantity 2900 g
Cooling Capacity
7000 Watt
24000 BTU / h
Heating Capacity
7000 Watt
28000 BTU / h
Airflow / Evaporator Airvolume
950 m3 / h
Dehumidifying Capacity
2.8 l / h
Power Supply
Input (max.) 3700 W
Power Consumption
Cooling 2900 W
Heating 3200 W
Noise Level
Indoor - unit 46 dB(A)
Outdoor - unit 61 dB(A)