Transition Networks 1004 User Manual

(E-TBT-HB-1004)
7366.C
For assistance in installing, using, or maintaining the TRANSITION Networks Model 1004 Ethernet™ Repeater Hub, contact TRANSITION Networks Technical Support
at:
(800) 260-1312
or contact your local distributor.
Model 1004
12-Port Ethernet Hub
MODEL 1004 12-PORT HUB
SPECIFICATIONS
Standards
IEEE 802.2, 802.3
Physical
Dimensions
17.0" X 7.5" X 1.7" (432 mm x 191 mm x 43 mm
Input Power
Universal Power Supply
Input Range: 85 to 265 VAC at 47 to 63 Hz.
(Rated at 40 watts maximum.)
AC Input:
TN PN Requirement Location
3344 120 volts, 60 hertz USA/Canada/Mexico 3344 100 volts, 50-60 hertz Japan 3347 230 volts, 50 hertz Europe 3348 240 volts, 50 hertz Australia 3349 240 volts, 50 hertz United Kingdom
Environment
Temperature: 0-50°C (32° to 122° F ) Humidity 10-90%, non condensing Altitude 0-10,000 feet
Warranty
5 years
21
Model 1004 12-Port Ethernet™ Repeater Hub
20
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Compliance Information UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
European Regulations Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Copyright Restrictions
© 1995, 1996 TRANSITION Networks Inc. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks Inc.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
10Base2 Cable Specifications
The physical characteristics of the 10Base2 cable must meet or exceed IEEE 802.3 10Base2 specifications.
Cable Characteristics:
Cable type: Stranded Coaxial RG58 (ThinNet) Impedance: 50 Ω @ 10 MHz Mutual Capacitance: 24 pF/ft ±20% @ 10 MHz
Maximum Cable Length
: 185 meters (610 feet)
Maximum number network connections:30 Minimum distance between connections: 0.5 meters (1.6 feet)
Terminate 10Base2 cable at one end using a 50 ohm terminator and at the other end using a 50 ohm terminator grounded to earth ground.
10BaseT Cable and Connector Specifications
The physical characteristics of the 10BaseT cable must meet or exceed IEEE 802.3 10BaseT specifications.
10BaseT Cable Characteristics:
Category 3 wire or better is required; category 5 wire is recommended. Either shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.
Category 3:
Gauge 24 to 22 AWG Attenuation 28 dB/1000’ @ 10 MHz Differential Characteristic Impedance 100 ±10% @ 10 MHz
Category 5:
Gauge 24 to 22 AWG Attenuation 20 dB/1000’ @ 10 MHz Differential Characteristic Impedance 100 ±10% @ 10 MHz
Maximum Cable Length: 100 meters (330 feet)
10BaseT Connector Characteristics:
The two active pairs in a 10BaseT network are pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins. 10BaseT cable for unlike devices (such as hub to terminal device) must be configured as straight through; 10BaseT cable for like devices (such as hub to hub or terminal device to terminal device) must be configured as crossover.
Straight Through Cable
Twisted Pair #1
Twisted Pair #2
Connectors for unlike devices
1 2
3 6
1
Twisted Pair #1
2
3
Twisted Pair #2
6
Connectors for like devices
Crossover Cable
1 2
3 6
1 2
3 6
Table of Contents
1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . 1
The Model 1004 Repeater Hub . . . . . . . . . . . . . . . . . . . . . . .1
Model 1004 Repeater Hub Features . . . . . . . . . . . . . . . . . . . . .1
Networking the Model 1004 Repeater Hub . . . . . . . . . . . . . . . .2
Model 1004 Repeater Hub Connectors, Indicators,
and Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2 SITE CONSIDERATIONS. . . . . . . . . . . . . . . . . . . . 4
Ensuring Correct Segment Number . . . . . . . . . . . . . . . . . . . .5
Ensuring Correct 10BaseT Configuration . . . . . . . . . . . . . . . .8
3 INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Unpacking the Model 1004 Repeater Hub . . . . . . . . . . . . . .7
Installing Slide-In Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Installing Model 1004 Repeater Hub . . . . . . . . . . . . . . . . . . .9
Connecting Cable to SIC and RJ-45 Connectos . . . . . . . . . .r10
BNC Connector/10Base2 Connection . . . . . . . . . . . . . . . . . . .10
Twisted Pair Connector/10BaseT Connection . . . . . . . . . . . . .11
Female AUConnector/10Base5 or Transceiver Connection . . .12
Male AUIConnector/PC Connection . . . . . . . . . . . . . . . . . . . .13
Fiber OpticConnector/10BaseFL Connection . . . . . . . . . . . . . .13
Connecting Power to Model 1004 Repeater . . . . . . . . . . . .14
4 OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Monitoring Power LED . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Monitoring Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
5 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . 16
Fault Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Technical Support Contact . . . . . . . . . . . . . . . . . . . . . . . . .16
WARRANTY STATEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
ETHERNET CABLE SPECIFICATIONS. . . . . . . . . . . . . . . . . . 19
MODEL 1004 12-PORT HUB SPECIFICATIONS . . . . . . . . 21
i
19
ETHERNET CABLE SPECIFICATIONS
AUI Cable and Connector Specifications
The cable is a special 4-pair individually shielded with an overall braided shield.
Maximum AUI Cable Length: 50 meters (165 feet) AUI Connector Characteristics:
AUI Port: Male DB-15 with locking posts. AUI Connection: Cable shell must be grounded. Connector Legend: 1 Logic Ref. 6 Power Return 11 Logic Ref
2 Collision+ 7 N/C 12 Receive 3 Transmit+ 8 Logic Ref. 13 Power 4 Logic Ref. 9 Collision-- 14 Logic Ref. 5 Receive+ 10Transmit- 15 N/C
10BaseFL Cable and Connector Specifications
The physical characteristics of the 10BaseFL cable must meet or exceed IEEE
802.3 10BaseFL specifications.
10BaseFL Cable Characteristics:
Fiber Optic Cable Recommended: 62.5/125 µm multimode fiber Optional: 100/140 µm multimode fiber
85/125 µm multimode fiber 50/125 µm multimode fiber
Fiber Optic Transmitter Power: Average power: -15.0 dBm
Peak power:-12.0 dBm ±1dBm
Fiber Optic Receiver Sensitivity: Average sensitivity: -27.4 dBm
Bit error rate: 10
-10
Maximum Cable Length: 2000 meters (6500 feet)
10BaseFL Connector Characteristics:
ST type connectors (SMA type available upon request)
10Base5 Cable and Connector Specifications
The physical characteristics of the 10Base5 cable must meet or exceed IEEE 802.3 10Base5 specifications.
10Base5 Cable Characteristics:
Cable type: RG8 Solid Coaxial (ThickNet) Impedance: 50 Ω @ 10 MHz Capacitance: 26pF/ft
Maximum Cable Length: 500 meters (1650 feet) Maximum number network connections: 100 Minimum distance between connections: 2.5 meters (8.2 feet)
Terminate 10Base5 cable at one end using a 50 ohm terminator and at the other end using a 50 ohm terminator grounded to earth ground.
Maximum number of terminal devices on Ethernet network: 1024
18
1
1. INTRODUCTION
This guide is intended for the system or network administrator responsible for installing and monitoring a TRANSITION Networks Model 1004 12-Port Ethernet™ Repeater Hub. A working knowledge of local area network (LAN) operations, including familiarity with communications protocols used on interconnected LANs, is assumed.
The Model 1004 Repeater Hub
The TRANSITION Networks Model 1004 12-Port Ethernet™ Repeater Hub, is a small, multi-purpose Ethernet repeater that is site­configurable, using an optional Slide In Card (SIC), for various signal transmission media.
Twelve fixed RJ-45 twisted-pair connectors
SICs, if installed, provide fiber optic, male and female AUI, BNC, or RJ-45 connectors.
SICs allow future network expansion or modification
The sole purpose of this remedy shall be provided the customer with the replacement or repair of non-conforming goods in the manner described in this Warranty statement. This exclusive remedy shall not be deemed to have failed of its essential purpose so long as TN is willing and able to repair or replace the defective item(s) or refund the purchase price.
TN reserves the right to inspect products claimed to be defective under warranty either at the customer’s location or at TN’s plant. TN assumes no liability for liability charges incidental to the adjustment, service, repairing, removal or replacement of the product, or other costs, or the expense of repairs made outside of its factory, except when made with TN’s prior written consent. Additionally, Transition Networks reserves the right to charge for all testing and shipping incurred, if after testing, a return is classified as “No Problem Found”.
TN’s total liability in connection with the products and their installation to all persons and from all causes in the aggregate, whether in contract, tort, or strict liability, shall not exceed the amount paid to TN for the product directly related to the alleged damage. However, in no event shall TN have any liability to a customer or any third party for products manufactures according to the customer’s specifications.
C. Return Procedure
The customer must follow this procedure for the return of defective items:
1. Locate the serial number(s) of the item(s) to be returned.
2. Determine the date the item(s) was received.
3. Contact Transition Networks Technical Support to determine if the problem can be corrected on site.
If not, and the product is covered by warranty, then:
• Call the distributor directly or contact TN.
• Request a Return Material Authorization (RMA).
• Ship the item, prepaid in original packaging to Transition Networks at the above address.
• Include the RMA number on the outside of the carton and/or on the Packing List.
• Include a copy of the RMA form.
• Include a copy of the original invoice or packing list (if possible) to expedite processing.
• The item(s) may be shipped by the customer or the distributor.
• Transition Networks will repair or replace the unit, at TN’s discretion, and cover the cost of the return freight to the distributor or to the customer, whichever requested the RMA number.
If the item(s) was received more than five years ago, or if the item(s) is no longer covered by warranty for other reasons, then:
• Call the distributor or contact TN.
• Request a Material Repair Authorization number (MRA).
• Ship the item(s), prepaid, in the original packaging to Transition Networks at the above address.
• Include the MRA number on the outside of the carton add/or on the Packing List.
• Include a copy of the MRA form.
• Include a copy of the original invoice or packing list (if possible) to expedite processing.
• Only the customer (end-user) may send the items(s) to TN.
• TN will contact the customer after the item(s) have been received, inspected, and a cost estimate of the repair determined.
• The repair charges may be billed, with customer’s approval, though the distributor, or on a prepaid or C.O.D. basis directly to the customer. The charges will include the cost of shipping.
The return authorization numbers are valid only for 90 days from the date issued.
TRANSITION
Port 1
MDI MDI-X
Power
LAN Master T12
networks
12 3 4 5 6 7 8 9101112
L/P
L/PRL/PRL/PRL/PRL/PRL/PRL/PRL/PRL/PRL/PRL/P
R
12 Port Ethernet 10BaseT Hub w/ SIC Slot
R