Transition Networks CPSFM-200 User Manual

USER’S GUIDE
CPSFM-200
Fan Module
• PointSystem™
• CPSMC18xx-xxx Accessory
• CPSMC19xx-100 Accessory
The Transition Networks CPSFM-200 fan module is a slide-in-module that provides optional additional cooling to the CPSMC18xx-xxx (18-slot) and the CPSMC19xx­100 (19-slot) PointSystem™ chassis and any installed media converter slide-in­modules and management modules.
The CPSFM-200 may be installed in either the AC-powered or the DC-powered, 18-slot or 19-slot, PointSystem™ chassis. The drawing below shows the CPSFM­200 installed in the back of a AC-powered PointSystem™ chassis.
CPSFM-200 Fan ModuleAC-Powered PointSystem Chassis
I 0
NOTE: The CPSFM-200 fan module is required in PointSystem™ applications where the ambient temperatures approach 60°C.
Installation . . . . . . . . . . . . . . . .2
Technical Specifications . . . . . .3
Contact Us . . . . . . . . . . . . . . . .3
Compliance Information . . . . . .4
CPSFM-200
Installation
NOTE: The CPSFM-200 fan module may be “hot swapped” (i.e., installed in
the chassis while the chassis is in operation).
To install the CPSFM-200 fan module into either the CPSMC18xx-xxx or the CPSMC19xx-100 PointSystem™ chassis:
1. Remove and retain the two (2) screws that secure the protective plate to the chassis.
2. Pull the plate away from the chassis.
I 0
3. Carefully slide the fan module into the installation slot, aligning the module with the installation guides.
I 0
4. Ensure that the fan module is firmly seated inside the chassis.
5. Carefully install the two (2) screws (retained in step 1) through the fan module and into the chassis, rotating clockwise to secure.
6. Verify that the fan module is powered by observing the fan operation.
Technical Specification
For use with Transition Networks Model CPSFM-200 or equivalent.
Standards FCC & CISPR Class A&B; CE Mark
Dimensions 8.3" x 8.4" x 2.7" (211 mm x 211 mm x 69 mm)
Weight 1 lb. (0.45 kg) (approximate)
Power Consumption 4.5 watts
MTBF 145,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
639,000 hours (Bellcore7 V5.0)
Environment Tmra*: 0 to 60°C (32 to 140°F )
Storage Temperature: -20 to 85°C (-4 to 185°F) Humidity: 5 to 95%, non condensing Altitude: 0 to 10,000 feet
Warranty Lifetime
*Manufacturer’s rated ambient temperature: Tmra range for this fan module depends on the physical characteristics and the installation configuration of the Transition Networks PointSystem™ chassis in which this module will be installed.
Contact Us
Technical Support
Technical support is available 24 hours a day. US and Canada: 1-800-260-1312 International: 00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
techsupport@transition.com
Address
Transition Networks 6475 City West Parkway Minneapolis, MN 55344, USA telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322
Tech Support: 1-800-260-1312 -- International: 00-1-952-941-7600 -- (24 hours)
2
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
Compliance Information
CISPR22/EN55022 Class A & B CE Mark FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A&B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A&B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A&B prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
Declaration of Conformity
Name of Mfg: Transition Networks
Model: CPSFM-200 Fan Module Part Number(s): CPSFM-200 Regulation: EMC Directive 89/336/EEC Purpose: To declare that the conformity with the following standards.
CISPR 22: 1993; EN 55022:1998 Class A&B; EN 55024:1998
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
Stephen Anderson, Vice-President of Engineering Date
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2000, 2004-2005 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or means (graphic, electronic, mechanical) without written permission from Transition Networks.
Printed in the U.S.A.
6475 City West Parkway, Minneapolis MN 55344 USA
CPSFM-200
to which this declaration refers is in
_July 8, 2000_____
33193.C
Loading...