TP-Link TL-SG1210P User Manual

LED Explanation
Power
On: Power on
O: Power o
© 2020 TP-Link 7106508685 REV4.0.0
PoE Status
On: Providing PoE power Flashing: PoE fault
O: Not providing PoE power
Installation Guide
Gigabit Desktop PoE+ Switch
Package Contents: Switch, Power Adapter, Power Cord and Installation Guide. Note: For simplicity, we will take TL-SG1008P for example throughout the Guide.
Connection
Ethernet Ports (1-8)
Internet
PoE MAX (For TL-SG1008P)
On: 57 W≤Total power supply < 64 W Flashing: Total power supply ≥ 64 W
O: Total power supply < 57 W
PoE MAX (For TL-SG1210P)
On: 56 W≤Total power supply < 63 W Flashing: Total power supply ≥ 63 W
O: Total power supply < 56 W
Green On: Running at 1000 Mbps, but no activity. Green Flashing: Running at 1000 Mbps and is transmitting or receiving data. Yellow On: Running at 10/100 Mbps, but no activity. Yellow Flashing: Running at 10/100 Mbps and is transmitting or receiving data.
O: No device is linked to the corresponding port.
DC Power Adapter
AC Power Cord
Router
LAN PortWAN Port
PC
Note:
1. TL-SG1210P has two uplink ports, which typically connect to uplink devices like routers.
Uplink 1 is an SFP port and works with a 1000 Mbps SFP module. Uplink 2 is an RJ45 port.
2. PoE ports typically connect to PoE Devices. Besides, PoE ports can also connect to non-PoE
devices, but only transmit data.
3. For TL-SG1008P, maximum PoE power is 30 W for each PoE port and 64 W for all PoE ports in total. For TL-SG1210P, maximum PoE power is 30 W for each PoE port and 63 W for all PoE ports in total.
PoE Disclaimer:
PoE budget calculations are based on laboratory testing. Actual PoE power budget is not guaranteed and will vary as a result of client limitations and environmental factors.
PoE Devices
IP Camera AP
PoE Ports (1-4)
IP Phone
Frequently Asked Questions (FAQ)
Specications
Q1. Why is the Power LED not lit?
The Power LED should be lit when the power system is working normally. If the Power LED is not lit, please try the following:
A1: Make sure the AC power cord is connected to the switch with power source
properly.
A2: Make sure the voltage of the power supply meets the requirements of the
input voltage of the switch.
A3: Make sure the power source is on.
Q2. Why is the Link/Act LED not lit while a device is connected to the corresponding port?
Please try the following:
A1: Make sure that the cable connectors are rmly plugged into the switch and
the device.
A2: Make sure the connected device is turned on and works normally.
A3: The cable must be less than 100 meters long (328 feet).
Q3. Why is PoE/PoE+ ports not supplying power for PoE devices?
If total power consumption of connected PoE devices exceeds the maximum, the system will cut o the power to ports with the lowest PoE priority. A PoE port with a smaller index number has a higher PoE priority.
Take TL-SG1008P as an example. If port 1, 2 and 4 are consuming 15.4 W respectively, and an additional PoE device with 19 W is connected to port 3, the total power consumption exceeds 64 W, so the system will cut o the power to
port 4.
General Specications
IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x,
Standard
Protocol
Interface
Network Media (Cable)
Backbone Bandwidth
MAC Address Table
Transfer Method
MAC Address Learning
Power Supply
Wall Mountable
Distance Between
Mounting Holes
IEEE 802.3af, IEEE 802.3at, IEEE 802.1p
IEEE 802.3z (Only for TL-SG1210P)
CSMA/CD
For TL-SG1008P: 8 10/100/1000 Mbps RJ45 Ports, Auto-Negotiation
MDI/MDIX;
PoE Ports: Port 1-Port 4, Total Power Supply: 64 W
For TL-SG1210P: 9 10/100/1000 Mbps RJ45 Ports, Auto-Negotiation
MDI/MDIX; 1 1000 Mbps SFP port;
PoE Ports: Port 1-Port 8, Total Power Supply: 63 W
10BASE-T: UTP category 3, 4, 5 cable (maximum 100 m); EIA/TIA-568 100 Ω STP (maximum 100 m)
100BASE-TX: UTP EIA/TIA-568 100 Ω STP (maximum 100 m)
1000BASE-T: UTP 100 m); EIA/TIA-568 100 Ω STP (maximum 100 m)
1000BASE-SX/LX/LX10/BX10: MMF, SMF (For TL-SG1210P)
TL-SG1008P: 16 Gbps TL-SG1210P: 20 Gbps
4K
Store-and-Forward
Automatically learning, automatically aging
External Power Adapter
Input: 100-240 V AC, 50/60 Hz Output: 53.5 V DC/1.31 A
Ye s
TL-SG1008P: 105 mm TL-SG1210P: 150 mm
category
5, 5e
cable (maximum
100
m);
category 5e cable or above (maximum
To ask questions, find answers, and communicate with TP-Link users or
engineers, please visit https://community.tp-link.com to join TP-Link
Community.
For technical support and other information, please visit
https://www.tp-link.com/support, or simply scan the QR code.
If you have any suggestions or needs on the product guides, welcome
to email techwriter@tp-link.com.cn.
Safety Information
Keep the device away from water, re, humidity or hot environments. Do not attempt to disassemble, repair, or modify the device. Do not use damaged charger or USB cable to charge the device. Do not use any other chargers than those recommended. Adapter shall be installed near the equipment and shall be easily accessible.
Place the device with its bottom surface downward.
Use only power supplies which are provided by manufacturer and in the origin packing of this
product. If you have any questions, please don’t hesitate to contact us.
Environmental and Physical Specications
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
EU Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other
relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp-link.com/en/ce
0˚C to 40˚C (32˚F to 104˚F)
-40˚C to 70˚C (-40˚F to 158˚F)
10% to 90%RH non-condensing
5% to 90%RH non-condensing
Loading...
+ 1 hidden pages