The Actuating Motor 741 is designed to operate any of the tekmar 3-way and 4-way brass mixing valves from type 710 through to type 724. The 741 provides 6 N•m (53 in•lbs) of torque over a 90° rotation. The actuating motor rotates its output shaft whenever 24 V (ac) is applied between either the counter clockwise ( ) or clockwise ( ) terminals and the Com terminal. The motor is compatible with any control having a 24 V (ac) floating output.
Installation
STEP ONE
-------------- GETTING READY
----------------------------------------------------------------------------------------------------
Check the contents of the package. If any of the items listed below are missing or damaged, please refer to the Limited Warranty and Product Return Procedure on the back of this brochure and contact your wholesaler or local tekmar representative.
Type 741 includes: • One Actuating Motor 741, One coupler with white arrow, One coupler with red arrow, One hand wheel with red indicator stripe, Two anti-rotation bolts & One Manual 741_D.
STEP TWO
• Remove the manual valve handle from the mixing valve.
• Thread the two anti-rotation bolts to the two top holes on the valve body.
• Use the following chart to select the proper coupler:
Type Coupler Arrow Color
710, 711, 712, 713, 714 White 720, 721, 722, 723, 724 Red
• The arrow on the coupler points towards the valve body. Place the coupler onto the
------------- MOUNTING
-----------------------------------------------------------
Hand Wheel
Actuating Motor
Coupler
valve shaft.
• Set the actuating motor’s automatic / manual selector to the manual setting.
• Place the actuating motor onto the coupler. Ensure that the actuating motor’s rotation range matches that of the mixing valve. Manually rotate the valve using the actuator hand wheel.
• Ensure the actuating motor’s hand wheel position indicator (clear plastic film with
Anti-Rotation Bolts
red stripe) indicates the proper direction to open the valve. If required, the clear position indicator can be reversed.
• Remove the hand wheel and fasten the actuating motor to the mixing valve using the screw under the hand wheel. Replace the hand wheel when finished.
• Set the actuating motor’s automatic / manual selector to the automatic setting.
Valve
STEP THREE
• Use a Phillips screwdriver to remove the two screws on the top of the actuating motor to remove the wiring cover.
• All electric wiring enters the actuating motor through the 1/2" (12 mm) conduit hole on the bottom. Standard 18 AWG solid
---------- WIRING
----------------------------------------------------------------
wire is recommended for all connections to the motor terminals.
The actuating motor is not suitable for use with rigid conduit.
• The diagram below shows wiring for clockwise to open. Reverse the Open and Close wires for counter clockwise to open.
• Use the Test button on the mixing control to verify that the mixing valve fully opens and closes.
• The protection provided by the equipment may be impaired if not installed in a manner specified by these instructions.
RR
C Opn Cls
Mixing Control
Powered Output
1 of 2 © 2014 741_D - 03/14
Clockwise
to Open
C 123
Actuating Motor 741
Transformer
R
Class 2
24 V (ac)
R Opn Cls
Mix
Mixing Control
Unpowered Output
Clockwise
to Open
C 123
Actuating Motor 741
Replacement Parts and Accessories
Actuating Motor Handle Kit M3045 includes: • One hand wheel with red indicator stripe, One screw with screw
adaptor.
Coupling Kit M3046 includes: • One replacement coupler with white arrow, One replacement coupler
with red arrow, Two replacement anti-rotation bolts.
Actuating Motor Adaptor Kit M3048 includes: • Two pairs of anti-rotation bolts that allow the Actuating Motor 741 to
mount onto the following mixing valves:
Mixing Valve Types Size Anti-rotation bolt size Coupler Arrow Color
Danfoss or ESBE 3MG 1/2" through 1-1/4" Small White Danfoss or ESBE 4MG 1/2" through 1-1/4" Small Red Danfoss or ESBE G1 series 1-1/2" through 2" Large White Danfoss or ESBE G4 series 1-1/2" through 2" Large Red
Technical Data
Actuating Motor 741 Floating Action
Literature — 741_D Packaged Weight — 1.2 lb. (520 g) Enclosure — Blue PPO plastic Approvals Ambient conditions — Indoor use only, 32 to 122°F (0 to 50°C)
Power Supply — 24 V (ac) ±10%, 60 Hz
— CSA C US, CSA/UL 61010-1
RH 90%, Altitude <3000 m, Installation Category I, Pollution Degree 2
Control signal — 24 V (ac), floating action, 1.5 VA Angle of rotation — Electrically limited to 90° shaft rotation Running time — 105 seconds at 60 Hz Maximum torque — 6 N•m (53 in•lbs)
Limited Warranty and Product Return Procedure
Limited Warranty The liability of tekmar under this warranty is lim-
ited. The Purchaser, by taking receipt of any tekmar product (“Prod­uct”), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same.
The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer’s pass-through warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Product is installed and used in compliance with tekmar’s instructions, ordinary wear and tear excepted. The pass-through warranty period is for a period of twenty-four (24) months from the production date if the Product is not installed during that period, or twelve (12) months from the docu­mented date of installation if installed within twenty-four (24) months from the production date.
The liability of tekmar under the Limited Warranty shall be limited to, at tekmar’s sole discretion: the cost of parts and labor provided by tekmar to repair defects in materials and/or workmanship of the defective prod­uct; or to the exchange of the defective product for a warranty replace­ment product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product liabil­ity, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in work­manship or materials, including any liability for fundamental breach of contract.
The pass-through Limited Warranty applies only to those defective Prod­ucts returned to tekmar during the warranty period. This Limited War­ranty does not cover the cost of the parts or labor to remove or transport the defective Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser’s agreement and warranty with its customers.
Any representations or warranties about the Products made by Purchaser to its customers which are different from or in excess of the tekmar Lim­ited Warranty are the Purchaser’s sole responsibility and obligation. Pur­chaser shall indemnify and hold tekmar harmless from and against any and all claims, liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Pur­chaser to its customers.
The pass-through Limited Warranty does not apply if the returned Prod­uct has been damaged by negligence by persons other than tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, alterations or attachments made subsequent to purchase which have not been authorized by tekmar; or if the Product was not installed in compliance with tekmar’s instructions and/or the local codes and ordinances; or if due to defective installation of the Product; or if the Product was not used in compliance with tekmar’s instructions.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHICH THE GOVERNING LAW ALLOWS PARTIES TO CONTRACTUALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DURABILITY OR DESCRIPTION OF THE PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-VIOLA­TION OF ANY APPLICABLE ENVIRONMENTAL, HEALTH OR SAFETY LEGISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY CONTRACTUALLY EXCLUDED IS LIMITED SUCH THAT IT SHALL NOT EX TEND BEYON D TWE NTY-FOUR (24) MONT HS F ROM THE PRODUC ­TION DATE, TO THE EXTENT THAT SUCH LIMITATION IS ALLOWED BY THE GOVERNING LAW.
Product Warranty Return Procedure All Products that are believed to have defects in workmanship or materials must be returned, together with a written description of the defect, to the tekmar Representative assigned to the territory in which such Product is located. If tekmar receives an inquiry from someone other than a tekmar Representative, including an inquiry from Purchaser (if not a tekmar Representative) or Purchaser’s customers, regarding a potential warranty claim, tekmar’s sole obligation shall be to provide the address and other contact informa­tion regarding the appropriate Representative.
tekmar Control Systems Ltd., A Watts Water Technologies Company.
Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarControls.com
Product design, software and literature are Copyright ©2014 by tekmar Control Systems Ltd.,
A Watts Water Technologies Company
2 of 2
Head Offi ce: 5100 Silver Star Road,
All specifications are subject to change without notice.
Printed in Canada. 741_D - 03/14.
Loading...