1.Before Starting Adjustments ···········································6-1
1-1. Adjusting Items when Replacing
Main Parts and Boards ···················································· 6-2
6-1. Camera Section Adjustments··········································· 6-4
1-1. Preparations before Adjustments (Camera Section)········6-4
1-1-1.List of Service Tools························································6-4
1-1-2.Preparations ·····································································6-5
1-1-3.Precaution········································································6-6
1.Setting the Switch····························································6-6
2.Order of Adjustments ······················································6-6
3.Subjects ··········································································· 6-6
1-2. Initialization of 8, A, C, D, E, F, 1C, 1F Page Data ········6-7
1-2-1.Version Check··································································6-7
1.Discrimination Method by the Model Name of IC4501
Commander ·····································································6-7
1-2-2.Initialization of A, D Page Data ······································6-8
1.Initializing the A, D Page Data········································6-8
2.Modification of A, D Page Data ······································6-8
5.1C Page Table ································································6-12
1-2-4.Initialization of E, F, 1F Page Data ·······························6-13
1.Initializing the E, F, 1F Page Data·································6-13
2.Modification of E, F, 1F Page Data ·······························6-13
5.1F Page Table ································································6-14
1-3. Camera System Adjustments·········································6-15
(Using the Minipattern Box) ·········································6-16
3.Flange Back Adjustment
(Using the Flange Back Adjustment Chart
and Subject More than 500 m Away) ···························· 6-17
3-1. Flange Back Adjustment (1)··········································6-17
3-2. Flange Back Adjustment (2)··········································6-17
4.Flange Back Check························································6-18
3.LCD White Balance Adjustment (PD-204 Board) ········6-27
6-2. Mechanism Section Adjustments ··································6-28
2-1. Adjustment Remote Commander ··································6-28
2-2. How to Enter Record Mode without Cassette ···············6-28
2-3. How to Enter Playback Mode without Cassette ············ 6-28
2-4. Tape Path Adjustment····················································6-29
2-4-1.Preparations for Adjustment ··········································6-29
2-4-2.Tape Path Adjustment····················································6-30
2-4-3.No.7 Guide (TG7) Adjustment ······································6-31
2-4-4.CUE, REV Waveforms Check·······································6-31
2-5. Checks After Adjustments ·············································6-31
2-5-1.Waveform Build-up Check ············································ 6-31
2-5-2.Tape Path Check ····························································6-31
6-3. Video Section Adjustments ··········································· 6-32
3-1. Preparations before Adjustments···································6-32
3-1-1.Equipment to Required··················································6-32
3-1-2.Precautions on Adjusting···············································6-33
3-1-3.Adjusting Connectors ····················································6-33
3-1-4.Connecting the Equipment ············································6-33
3-1-5.Alignment Tape ·····························································6-34
3-1-6.Input/output Level and Impedance································6-35
3-2. System Control System Adjustments ····························6-36
1.Initialization of 8, A, C, D, E, F, 1C, 1F Page Data ······6-36
2.Node Unique ID No. Input ············································6-36
2-1. Input of Company ID ···················································· 6-36
2-2. Input of Serial No. ·························································6-36
3-3. Servo and RF System Adjustments ······························· 6-38
6-4. Service Mode·································································6-44
4-1. Adjustment Remote Commander ··································6-44
1.Using the Adjustment Remote Commander··················6-44
2.Precautions Upon Using
the Adjustment Remote Commander ····························6-44
4-2. Data Process ··································································6-45
4-3. Service Mode·································································6-46
1.Setting the Test Mode ····················································6-46
7.LED, Video Light, IR Light Check ·······························6-50
8.Record of Use Check·····················································6-51
9.Record of Self-diagnosis Check ····································6-52
* The camera optical axis frame is shown on page 6-53.
The camera color reproduction frame is shown on page
6-54.
— 2 —
1.Before Starting Adjustments
(Machine before starting repair)
(Machine after a board is replaced)
PCPC
Save the EVR data
to a personal computer.
Download the saved
data to a machine.
EVR Data Re-writing Procedure When Replacing Board
The data that is stored in the repair board, is not necessarily correct.
Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.
Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a
board is replaced.
DCR-TRV255E/TRV260/TRV265/TRV265E
SECTION 6
ADJUSTMENTS
Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed
EEPROM to the replaced board.
Remove the EEPROM and install it.
(Former board)
(New board)
Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or
installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired)(Machine to be repaired)
PC
Download the data.
After the EVR data is saved and downloaded, chec k the
respective items of the EVR data.
(Refer to page 6-3 for the items to be checked)
Save the data.
(The same model of the same destination)
6-1
DCR-TRV255E/TRV260/TRV265/TRV265E
t
1-1. Adjusting Items when Replacing Main Parts and Boards
• Adjusting items when replacing main parts
When replacing main parts, adjust the items indicated by z in the following table.
Replaced part
Block replacement
Mounted part replacemen
Adjustment SectionAdjustment
Initialization of 8, A, C, D,
E, F, 1C, 1F page dataInitializing of 8, C, 1C page data
CameraHALL adj.z
LCDLCD level adj.z
System controlNode uniqe ID No. input
Servo, RFCAP FG/REEL FG duty adj.zz
Video27 MHz origin osillation adj.zz
MechanismTape path adj.
Initializing of A, D page data
Initializing of E, F, 1F page data
Flange back adj.zz
Optical axis adj.zz
Color reproduction adj.zz
LV standard data inputzz
AWB standard data inputzz
Auto white balance adj.zz
Steadyshot check
LCD V-COM adj.zz
LCD White balance adj.
Switching position adj.zz
SD error rate check (LP)
S VIDEO OUT Y level adj.zz
S VIDEO OUT C level adj.
(LCD panel)
(Fluorescent tube)
(Drum assembly) (Note 1)
(Capstan motor)
(CCD imager)
(Timing generator)
(S/H, AGC, A/D CONV.)
Lens device
Video light (Note 2)
LCD block LCD901
LCD block ND901
Mechanism deck (Note 1)
Mechanism deck M901
Mechanism deck M902
CD-471 board IC951
VC-344 board IC1501, X1501
VC-344 board IC1502
zzz
zzz
zz
zzz
(DV signal process, D/A Converter, Lens control)
(Y/C MIX, Buffer)
(EVR)
(LCD driver)
VC-344 board IC3301
VC-344 board IC6501
VC-344 board IC1601
PD-204 board IC6001
Table 6-1-1 (1)
Note 1: When replacing the drum assy or mechanism deck, reset the data of page: 7, address: A7 to A9.
(Refer to “Record of Use Check” of “6-4. SERVICE MODE”)
Note 2: When replacing the video light, reset the data of page: 7, address: CE and CF.
(Refer to “Record of Use Check” of “6-4. SERVICE MODE”)
6-2
DCR-TRV255E/TRV260/TRV265/TRV265E
• Adjusting items when replacing a board or EEPROM
When replacing a board or EEPROM, adjust the items indicated by z in the following table.
Replaced part
Adjustment SectionAdjustment
(COMPLETE)
(COMPLETE)
(EEPROM)
RadarWRadarWRadarW
PD-204 board
VC-344 board
VC-344 board IC4502
Supporting
Initialization of 8, A, C, D,
E, F, 1C, 1F page dataInitializing of 8, C, 1C page datazz
CameraHALL adj.zzz
LCDLCD level adj.zzzz
System controlNode uniqe ID No. input
Servo, RFCAP FG/REEL FG duty adj.zzz
Video27 MHz origin osillation adj.zz
MechanismTape path adj.
Initializing of A, D page data
Initializing of E, F, 1F page data
Flange back adj.zzz
Optical axis adj.zz
Color reproduction adj.zz
LV standard data inputzzz
AWB standard data inputzzz
Auto white balance adj.zzz
Steadyshot check
LCD V-COM adj.zzz
LCD White balance adj.
Switching position adj.zzz
SD error rate check (LP)
S VIDEO OUT Y level adj.zz
S VIDEO OUT C level adj.
zz
zz
zzz
zzz
zz
zzz
zz
Table 6-1-1 (2)
6-3
DCR-TRV255E/TRV260/TRV265/TRV265E
6-1. CAMERA SECTION ADJUSTMENTS
1-1.PREPARATIONS BEFORE ADJUSTMENTS (CAMERA SECTION)
1-1-1.List of Service Tools
• Oscilloscope• Color monitor• Vectorscope
• Regulated power supply• Digital voltmeter• Frequency counter
Ref. No.
J-1
J-2
J-3
J-4
J-5
J-6
J-7
J-8
J-9
J-10
J-11
Filter for color temperature correction (C14)
ND filter 1.0
ND filter 0.4
ND filter 0.1
Pattern box PTB-450
Color chart for pattern box
Adjustment remote commander (RM-95 upgraded).
Siemens star chart
Clear chart for pattern box
CPC jig connector
I/F unit for LANC control
Mini pattern box
Camera table
Auto white balance adjustment/check
White balance adjustment/check
White balance check
White balance check
White balance check
For checking the flange back
For connecting the adjustment remote commander
For connecting the adjustment remote commander
For adjusting the flange back
For adjusting the flange back
Usage
J-1J-2
J-6
J-11
J-7J-8
J-3
J-4J-5
J-9J-10
Fig. 6-1-1
6-4
CN1011
A/V OUT jack
16
1
Audio L (white)
Audio R (red)
Video (yellow)
TV monitor
AC IN
AC adaptor
AC adaptor
CPC lid
I/F unit for LANC control
(J-6082-521-A)
Conductor side
L serices Info
LITHIUM battery (7.2Vdc)
Adjustment
remote commander (RM-95)
CPC jig connector
(J-6082-539-A)
LANC jack
AC IN
Terminated at 75Ω
Vector scope
Screw (M2)
1-1-2. Preparations
Note: Before perform the adjustment, check that the data of page:
0, address: 10 is “00”.
If not, select page: 0, address: 10, and set data “00”.
1) Connect the equipment for adjustments according to Fig. 6-1-
3.
2) Connect the adjustment remote commander to VC-344 board
CN1011 via I/F unit for LANC control (J-6082-521-A) and
CPC jig connector (J-6082-539-A). (Fig. 6-1-3)
To operate the adjustment remote commander, connect the AC
power adaptor to the DC IN jack of I/F unit for LANC control,
or connect the L series Info-LITHIUM battery to the battery
terminal of I/F unit for LANC control.
DCR-TRV255E/TRV260/TRV265/TRV265E
Pattern box
1 m
Front of the lens
Fig. 6-1-2
Fig. 6-1-3
6-5
DCR-TRV255E/TRV260/TRV265/TRV265E
1-1-3. Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette.
1. POWER switch (SS-5100 block) ..........................CAMERA
1) Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 6-1-4. (Color reproduction
adjustment frame)
2) Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time)
3) Chart for flange back adjustment
Join together a piece of white A0 size paper (1189mm × 841
mm) and a piece of black paper to make the chart shown in
Fig. 6-1-5.
Note: Use a non-reflecting and non-glazing vellum paper. The
size must be A0 or larger and the joint between the white
and black paper must not have any undulations.
Adjust the camera zoom and direction to
obtain the output wavef orm shown in Fig. a and
the monitor TV display shown in Fig. b.
White
841 mm
Black
1189 mm
Fig. 6-1-5
6-6
DCR-TRV255E/TRV260/TRV265/TRV265E
1-2.INITIALIZA TION OF 8, A, C, D , E, F, 1C, 1F
PAGE DATA
Note: If reading/writing data on pages 1C, 1F, set data: 01 to
page: 0, address: 10, and then select pages C, F. By this
data setting, the pages 1C, 1F can be selected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
1-2-1. Version Check
Due to the change of IC4501 (mechanism control), there are two
types of versions A and B.
The EEPROM data are different according to respecti v e v ersions.
Also, the IC4501 version can be checked by a discrimination
method by the model name or by the adjusting remote commander.
Note 1: Changing the version does not make any changes in sche-
matic diagrams and the rest.
Note 2: Make it sure to confirm the version after replacing
IC4501.
1. Discrimination Method by the Model Name of
IC4501 (Mechanism Control)
VC-344 BOARD (SIDE A)
2. Discrimination Method by Adjusting Remote
Commander
Version check method:
1) Select page: 3, and address: FF.
2) The version of IC4501 can be checked from the displayed data.
DataVersion
01A
02B
Data change method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 1C, and input the data in the following table.
Note: To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each
time to set the data.
3) Select page: 0, address: 01, and set data: 00.
Version
Address
D04042
AB
IC4501
154 : A
155 : B
Fig. 6-1-6
6-7
DCR-TRV255E/TRV260/TRV265/TRV265E
1-2-2. Initialization of A, D Page Data
Note: Check that the data of page: 0, address: 10 is “00”.
1. Initializing the A, D Page Data
Note 1: If “Initialization of Pages A, D” is executed, all data on
pages A, D are initialized. (Only an indi vidual page cannot be initialized)
Note 2: If the A, D page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, D page data
Note 3: NTSC model: DCR-TRV260/TRV265
PAL model: DCR-TRV255E/TRV265E
Adjustment PageA
Adjustment Address10 to FF
Adjustment PageD
Adjustment Address10 to 7F
Initializing method:
Order Page Address DataProcedure
10 0101
20 1000
Set the following data.
37 03
47 0028
57 0128Press PAUSE button.
67 02
7
00: NTSC model
80: PAL model
Check the data changes to
“01”.
Perform “Modification of A,
D Page Data”
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of
the“Fixed data-2” address shown in the following ta ble by manual
input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, cop y
the data built in the same model.
Note 1: If copy the data built in the different model, the
camcorder may not operate.
3) When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification A, D page data:
Order Page Address DataProcedure
12 0029
22 0129Press PAUSE button.
Note 2: If the following symptoms occur after completing of
the“Modification A, D page data”, check that the data of
the “Fixed data-2” addresses of A, D page are same as
those of the same model of the same destination.
1) The power is shut off so that unit cannot operate.
6-8
DCR-TRV255E/TRV260/TRV265/TRV265E
3. A Page Table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, D Page Data”)
Address
10 to 19Fixed data-1 (Initialized data)
1AFixed data-2
1B to 30Fixed data-1 (Initialized data)
31
32
33 to 49Fixed data-1 (Initialized data)
4AFixed data-2
4B to 4EFixed data-1 (Initialized data)
4FFixed data-2
50, 51Fixed data-1 (Initialized data)
52
53
54 to 64Fixed data-1 (Initialized data)
65Fixed data-2
66 to 7FFixed data-1 (Initialized data)
80
81
82 to 8FFixed data-1 (Initialized data)
90Fixed data-2
91 to 96Fixed data-1 (Initialized data)
97
98
99 to DFFixed data-1 (Initialized data)
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1
F2
F3
Initial value
NTSC PAL
Remark
Fixed data-2
Fixed data-2
Fixed data-2
A: Fixed data-2
B: Fixed data-1 (Initialized data)
(Refer to “1-2-1. Version Check”.)
Fixed data-2
Address
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE, FFFixed data-1 (Initialized data)
4. D Page Table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
Address
100000Test mode
11Fixed data-1 (Initialized data)
12
13
14 to 21Fixed data-1 (Initialized data)
22
23
24Fixed data-2
25
26
27 to 29Fixed data-1 (Initialized data)
2A
2B
2C to 35Fixed data-1 (Initialized data)
36
37Fixed data-2
38
39Fixed data-1 (Initialized data)
3AFixed data-2
3B to 55Fixed data-1 (Initialized data)
56Fixed data-2
57Fixed data-1 (Initialized data)
58Fixed data-2
59 to 6EFixed data-1 (Initialized data)
6FFixed data-2
70 to 7FFixed data-1 (Initialized data)
Initial value
NTSC PAL
Fixed data-2
the A, D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, D Page Data”)
Initial value
NTSC PAL
Fixed data-2
Fixed data-2
Remark
Remark
6-9
DCR-TRV255E/TRV260/TRV265/TRV265E
1-2-3. Initialization of 8, C, 1C Page Data
Note: If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages C. By this data setting, the pages 1C can be selected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
1. Initializing the 8, C, 1C Page Data
Note 1: If “Initialization of Pages 8, C, 1C” is executed, all data
on pages 8, C, 1C are initialized. (Only an individual
page cannot be initialized)
Note 2: If the 8, C, 1C page data has been initialized, the follow-
ing adjustments need to be performed again.
1) Modification of 8, C, 1C page data
2) Electronic viewfinder system adjustments
3) LCD system adjustments
4) Node unique ID No. input
5) Servo, RF system adjustments
6) “S VIDEO OUT Y le v el adjustment” and “S VIDEO
OUT C level adjustment” of video system adjustments.
Adjustment Page8
Adjustment Address00 to FF
Adjustment PageC
Adjustment Address10 to FF
Adjustment Page1C
Adjustment Address00 to FF
If the 8, C, 1C page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages 8, C, set data: 00 to page: 0,
address: 10, and then select pages 8, C.
3) If modification of data on pages 1C, set data: 01 to page: 0,
address: 10, and then select pages C. After the modification of
data finished, return the data on page: 0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, cop y
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data
to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification 8, C, 1C page data:
Order Page Address DataProcedure
10 1000
22 0029
32 0129Press PAUSE button.
3. 8 Page Table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 1C Page Data”)
Address
00 to ABFixed data-1 (Initialized data)
ACFixed data-2
AD to C3Fixed data-1 (Initialized data)
C4
C5
C6
C7
C8 to FFFixed data-1 (Initialized data)
Initial value
NTSC PAL
Remark
Fixed data-2
6-10
DCR-TRV255E/TRV260/TRV265/TRV265E
4. C Page Table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 1C Page Data”)
5. 1C Page Table
Note 1: If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages C. By this data setting, the pages 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 1C Page Data”)
1-2-4. Initialization of E, F, 1F Page Data
Note: Check that the data of page: 0, address: 10 is “00”.
1. Initializing the E, F, 1F Page Data
Note 1: If “Initialization of Pages E, F, 1F” is executed, all data
on pages E, F , 1F are initialized. (Only an individual page
cannot be initialized)
Note 2: If the E, F, 1F page data has been initialized, the follow-
ing adjustments need to be performed again.
1) Modification of E, F, 1F page data
2) “27 MHz Origin Oscillation Adjustment” of video
system adjustments
3) Camera system adjustments
Note 3: NTSC model: DCR-TRV260/TRV265
PAL model: DCR-TRV255E/TRV265E
Adjustment PageE
Adjustment Address00 to FF
Adjustment PageF
Adjustment Address10 to FF
Adjustment Page1F
Adjustment Address00 to FF
Initializing method:
Order Page Address DataProcedure
10 0101
20 1000
36 0301
Set the following data, and
46 01
56 02
6
press PAUSE button.
2D: NTSC model
2F: PAL model
Check the data changes to
“01”.
Perform “Modification of E,
F, 1F Page Data”
2. Modification of E, F, 1F Page Data
If the E, F, 1F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages E, F, set data: 00 to page: 0,
address: 10, and then select pages E, F.
3) If modification of data on pages 1F, set data: 01 to page: 0,
address: 10, and then select pages F . After the modification of
data finished, return the data on page: 0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE button of the adjustment remote commander each time when setting new data
to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification E, F, 1F page data:
Order Page Address DataProcedure
10 1000
22 0029
32 0129Press PAUSE button.
3. E Page Table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 1F Page Data”)
Address
00 to 0FFixed data-1 (Initialized data)
10Fixed data-2
11 to B0Fixed data-1 (Initialized data)
B1Fixed data-2
B2 to FFFixed data-1 (Initialized data)
Initial value
NTSC PAL
Remark
6-13
DCR-TRV255E/TRV260/TRV265/TRV265E
4. F Page Table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 1F Page Data”)
5. 1F Page Table
Note 1: If reading/writing data on pages 1F, set data: 01 to page:
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
Address
00 to 7BFixed data-1 (Initialized data)
7CFixed data-2
7D to FFFixed data-1 (Initialized data)
Initial value
NTSC PAL
Flange back adj.
Fixed data-2
0, address: 10, and then select pages F. By this data setting, the pages 1F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
the E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 1F Page Data”)
Initial value
NTSC PAL
Remark
Remark
6-14
1-3.CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “27 MHz Origin Oscillation Adjustment”, “S
VIDEO OUT Y level Adjustment” and “S VIDEO OUT C level
Adjustment” of “VIDEO SYSTEM ADJUSTMENT” are satisf ied.
Check that the data of page: 0, address: 10, is “00”.
If not, select page: 0, address: 10, and set data “00”
DCR-TRV255E/TRV260/TRV265/TRV265E
1. HALL Adjustment
For detecting the position of lens iris, adjust the hall AMP gain
and offset.
ModeCAMERA
SubjectNot required
Measurement PointDisplayed data of page: 1 (Note 3)
Measuring Instrument Adjusting remote commander
Adjustment PageF
Adjustment Address12 to 17
Specified value87 to 8B during IRIS OPEN
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: The right two digits of the page: 1 displayed data of the
(Note 3) during IRIS OPEN
satisfied the specified value.
Check that the displayed data
(Note 3) during IRIS CLOSE
satisfied the specified value.
6-15
DCR-TRV255E/TRV260/TRV265/TRV265E
2. Flange Back Adjustment
RadarWRadarWRadarW
(Using the Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during auto focusing/manual focusing.
ModeCAMERA
SubjectSiemens star chart with ND filter for
minipattern box (Note 1)
Measurement PointCheck operation on monitor TV
Measuring Instrument
Adjustment PageF
Adjustment Address44 to 54
Note 1: Dark Siemens star chart.
Note 2: Check that the data of page: 0, address: 10 is “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 4: Perform the adjustment with the camcorder in horizon-
tal state.
Note 5: Perform “HALL Adjustment” before this adjustment.
Switch setting:
1) NIGHTSHOT PLUS........................................................ OFF