ARGUS light-sensitive switches with/ without switching delay
Operating instructions
MTN544819, MTN544894, MTN544829
Connections, displays and operating elements
If you want to lead the cable into the housing from below rather than above:
4 Swap over the lead-in guides (A/B).
A
B
B
For your safety
DANG ER
¼
All work carried out on the unit may only be per­formed by skilled electricians. Obser ve the regu­lations valid in the country of use.
Light-sensitive switch introduction
The ARGUS light-sensitive switch with or without swit­ching delay can be connected to:
– ohmic loads (incandescent lamps, 230 V halogen
lamps)
– inductive loads (NV halogen lamps with wound
transformer)
– capacitive loads (electronic transformer)
As soon as the external brightness fails to reach a value which you set (twilight threshold), the light-sensitive switch will switch on the connected load. When the ex­ternal brightness increases again and exceeds the twi­light threshold, the load is switched off again.
The light-sensitive switches MTN544894 and MTN544819 also have a switching delay function which means that the load is only switched if the twilight thres­hold is exceeded or not reached for a longer period of ti­me. The light-sensitive switch therefore only reacts at dusk or dawn and not e.g. during the day due to tempora­ry cloud cover or at night due to the light cast from a headlamp.
A Opening for light sensor B Setting disk for twilight threshold C Connecting terminals D Light sensor E Openings for fixing F Lead-in guides for connecting cable G Switching delay On/Off (only MTN544894,
MTN544819)
Selecting the installation site
– If possible, install the device on the north- or eastfa-
cing wall of the building.
– If possible, install the device under roof overhangs or
similar covering.
– If possible, the connection cable should be inserted
into the device from below. If the connecting cable en­ters into the device from above, particularly good insu­lation must be ensured.
– Install the load to be switched (lighting) in such a way
that the light from it does not fall on the light sensor. Otherwise, the sensor will not be able to calculate the ambient brightness correctly (optical feedback).
Light-sensitive switch installation
1 Open the housing by unscrewing the two screws at
the front. Pull out the light-sensitive switch.
The condensation water opening on the underside of the housing must be opened. Exception: If operated in rooms subject to a large amount of dust, it must remain closed.
2 Push open the condensation water opening A
(view from rear) from the inside to the outside and break out the wall.
A
When switching inductive loads such as transfor-
|
mers, relays, contactors or fluorescent lamps, spikes occur which could lead to the load being switched on again ("maintained light effect"). Switch a capacitor parallel to the inductive load in order to reduce these spikes.
5 Wiring the light-sensitive switch for the desired ap-
plication:
– Light-sensitive switch with On/Off switch (optional)
L N
NL
– Light-sensitive switch with On/Off switch (optional)
and two-way switch for toggling between manual and automatic operation.
L N
NL
6 Insert the light-sensitive switch into th e housing and
screw the housing together.
Setting light-sensitve switch
Turning the switching delay on
3 Fasten the housing to the wall through the openings
using suitable fixing material (e.g. dowels and screws). The "TOP" marking should be at the top.
1 Turn the adjuster completely to the position “ON“
(as far as possible to the left).
Turning the switching delay off
1 Turn the adjuster completely to the position “OFF“
(as far as possible to the right).
Setting the twilight treshold
1 Slowly turn the setting disk at dawn or dusk, thus
closing the opening of the light sensor, until the load switches on or off.
V5448-565-00 04/08
Technical data
Nominal voltage: AC 230 V, 50 Hz Max. switching
current: 10 A, AC 230 V, cosϕ = 0.6 Nominal power
Incandescent lamps: AC 230 V, max. 2300 W
Halogen lamps: AC 230 V, max. 2000 W
Capacitive load: max 140 µF Connecting terminals: for 2.5 mm External diameter of a cable: max. 14 mm Adjustment range/ switch threshold: 3 -2000 Lux, adjustable Relay: µ contact Switching delay (MTN544894, MTN544819): Switching on: approx. 40 s
Switching off: approx. 100 s Type of protection: IP 54 Dimensions: approx. 97x80x47 mm (HxWxD)
2
rigid conductors
Schneider Electric Industries SAS
If you have technical questions, please contact the Cus­tomer Care Center in your country.
www.schneider-electric.com
This product must be installed, connected and used in compliance with prevailing standards and/or installation regulations. As standards, specifications and designs develop from time to time, always ask for confirmation of the information given in this publication.