Instructions
1336 PLUS, 1336 PLUS II, 1336 FORCE™ &
1336 IMPACT
(Catalog Number 1336-JBxx)
This publication will guide you through installation of the 1336-JBxx
Junction Box kit. Refer to the appropriate drive User Manual for
detailed drive information.
™
Junction Box Kit
Installation
Using thefollowinginformation and the Catalog Number Explanation
below, verify that you have the correct components.
• If the catalog number of your drive contains an “AA”
(i.e. 1336S-B030that ends in “A” (i.e. 1336-JBB
• If the catalog number of your drive contains an “AE”
(i.e. 1336S-B050that ends in “E” (i.e. 1336-JBC
• If the catalog number of your drive contains an “AN”
(i.e. 1336S-B030corresponding junction box are required.
Junction Box Catalog Number Explanation
AA-EN4), a junction box with a catalog number
A) is required.
AE-EN4), a junction box with a catalog number
E) is required.
AN-EN4), an Allen-Bradley Enclosure Kit and
1336 –JB –B –E
First Position Second Position Third Position Fourth Position
Description Frame Size Type
Description Letter Description Letter Description Letter Description
Bulletin
Number
!
JB Junction
Box
ATTENTION: The drive contains ESD (Electrostatic
Discharge) sensitive parts and assemblies. Static control
precautions are required when installing, testing, servicing
or repairing this assembly.Component damage may result
if ESD control procedures are not followed. If you are not
familiar with static control procedures, reference A-B
publication 8000-4.5.2, “Guarding Against Electrostatic
Damage”oranyotherapplicableESD protection handbook.
BCB Frame
C FrameAE
IP 20 (NEMA Type 1)
IP 20 (NEMA Type1) CE
ATTENTION: To avoid a shock hazard, assure that all
power to the drive has been removed before proceeding. In
!
addition, verify that the DC bus has discharged by
measuring across the “+DC” and “–DC” terminals of TB1
with a voltmeter. The voltage should be 0.0VDC.
2 1336 PLUS, 1336 PLUS II, 1336 FORCE™ & 1336 IMPACT™ Junction Box Kit
When a drivemounted HIM is not supplied on enclosed IP
!
1336 with IP20 (NEMA Type 1) Enclosure
Refer to Figure 1 for dimension information.
1. Remove and lock-out all power to the drive. Remove front cover.
2. Label and disconnect all wiring. External wiring will have to be
rerouted through the junction box, once it has been installed.
20 (NEMA Type 1) drives, the blank cover plate (option
HAB) must be installed to close the opening in the front
cover of the enclosure. Failure to install the blank cover
plate allows access to electrically live parts which may
result in personal injury and/or equipment damage.
When a drive mounted HIM is supplied with enclosed IP
20 (NEMA Type 1) drives, but has been removed from its
mountingcradlefor remote operation, the blankcoverplate
must be installed in place of the HIM.
3. Remove and discard existing bottom plate.
4. Install new bottom plate with junction box. Tighten all screws to
1.5 N-m (13 lb.-in.). Rewire drive and replace front cover.
1336 with IP20 (NEMA Type 1) CE Enclosure
Refer to Figure 1 for dimension information.
1. Access to the top, bottom and sides of the drive chassis will be
required. Remove and lock-out all power to the drive.
2. Remove screws securing enclosure assembly to chassis. Remove
enclosure.
3. Label and disconnect all wiring. External wiring will have to be
rerouted through the junction box, once it has been installed.
4. Removeand discard existing bottom plate. Install the new junction
box bottom plate.
5. Rewire drive.
6. Replace enclosure assembly and tighten all screws to 1.5 N-m