RISCO Group WL Internal Rectangular Sounder User Manual

Wireless Internal
Sounder
WL S40
Installation and Programming Instructions
Table of Contents
Introduction........................................................................................................... 4
Operational Functions.......................................................................................... 4
Alarm / Tamper Indication...................................................................................4
Low Battery Indication.........................................................................................4
Supervision .........................................................................................................4
Pre Alarm Indication............................................................................................4
Sounder Testing..................................................................................................4
Mounting the Sounder.......................................................................................... 5
Programming the sounder................................................................................... 6
Step 1: Sounder/Receiver Communication Set up..............................................6
Step 2: Setting the Sounder Parameters.............................................................6
Adjusting the Volume .................................................................................... 6
Muting Tamper.............................................................................................. 6
Setting Supervision Time .............................................................................. 7
Pre Alarm indication...................................................................................... 7
Step 3: Testing the Sounder ...............................................................................7
Communication Test ..................................................................................... 7
Diagnostics.................................................................................................... 7
Replacing Batteries .............................................................................................. 8
Technical Information........................................................................................... 9
Electrical .............................................................................................................9
Radio...................................................................................................................9
Environmental.....................................................................................................9
Wireless Sounder Instructions 3
Introduction
RISCO Group's two-way indoor wireless sounder is designed to extend the signaling capabilities of the RISCO Group WisDom and Agility wireless systems, within the protected area. The wireless sounder offers an easy and flexible solution for quick installation. The sounder is powered by its own batteries and communicate wirelessly with the security panel using 868MHz or 433MHz frequency band. Up to 3 wireless sounders can be assigned to a system.
Operational Functions
Alarm / Tamper Indication
Upon an alarm condition, the sounder will be activated for a period of time defined by the system (Bell Time Out parameter). The maximum time that the sound will be activated is 5 minutes.
Low Battery Indication
Upon a low battery condition a trouble indication is sent to the panel. There are 2 types of low battery indications:
Ê Radio low battery Ê Speaker low battery
Supervision
Each sounder can be defined to be supervised by the panel. The system generates a local trouble signal identifying the sounder which its signal is not received during a predefined time, followed by a report to the Central Station (if defined).
Pre Alarm Indication
When an entry time starts, the system transmits a pre-alarm signal to the sounder. If the system is disarmed before the entry delay time expires, a cancellation signal is sent to the sounder. If the sounder does not receive a canceling signal within the entry delay time, the sounder will be activated.
Sounder Testing
Once placing all batteries in place, the sounder performs a functional self test indicated by a squawk sound. Testing the sounder can also be performed remotely by the system keypad, or, using the remote configuration software.
Mounting the Sounder
1. Open the front cover by removing the cover locking screw located at the bottom of the unit.
2. Hold the back plate against the wall and mark the locations of the mounting holes. the desired mounting holes and insert the screw anchors.
3. Mount the back unit to the wall using the supplied screws.
4. Insert the supplied batteries paying attention to the polarity.
5. Perform communication set up with the control panel.
6. Once communication setup is complete, close the cover and locking screw.
Fixing Points to
Wall
Drill
Remove cover locking screw
Fig. 1 Fig. 2
Speaker
Tamper
Speaker Batteries
(6V, Serial
Connection)
Two Indication
LEDs
R E K A E P S
R E P M A T
Reset
Switch
Fig. 3: Internal Sounder - PCB Diagram
Radio Batteries
(3V, Parallel Connection)
Wireless Sounder Instructions 5
Programming the sounder
Programming the wireless sounder consists of the following 3 steps:
1. Setting communication between the receiver and the sounder
2. Setting sounder parameters
3. Testing the sounder
Step 1: Sounder/Receiver Communication Set up
The sounder must identify itself to the system's receiver by writing its ID into the System. Perform according to the following steps:
1. Set the receiver to the Write mode.
NOTE:
In the WisDom , as first step, you need to allocate the sounder in the following programming location:
Main engineer menu> 9) Devices > 2)Sounder > 1) Allocation > Select sounder> Choose INWS1
2. Select the sounder's ID.
3. Unpack the supplied batteries
4. Insert two speaker batteries into the batteries chamber (Fig. 3).
5. Insert three Radio batteries into the batteries chamber.
6. After a squawk is heard you have 10 seconds to press on the tamper switch for at least 3 seconds. If the sounder is successfully recognized, the system will sound a confirmation beep and the sounder will initiate a second squawk sound.
7. Repeat the process for other sounders in the system.
Step 2: Setting the Sounder Parameters
Each sounder can be defined with different sets of parameters. The following table describes the list of parameters of the sounder.
NOTE:
For the specific programming location of each parameter refer to the system manuals.
Adjusting the Volume
Defines the sounder sound volume for the following system modes
¾ Exit / Entry: The sound produced during Exit/Entry time (Default: 0) ¾ Alarm: The sound produced during alarm (Default: 9) ¾ Squawk: The sound produced during squawk sounds (Default: 9)
The sound volume range is between 0 (silent) to 9 (maximum volume).
Muting Tamper
This feature disables a tamper alarm from the sounder and it is rec ommended to be used when replacing sounder's batteries.
NOTES:
1. An ongoing tamper alarm will not be disabled.
2. WisDom: This feature is controlled under the Engineer Menu (Quick key [9][2][5]). Tamper alarm will be disabled during the current installation programming period.
3. Agility: This feature is controlled under the Grand Master menu. Tamper alarm will be disabled for 20 minutes.
Setting Supervision Time
Specifies how often the system generates a supervision request to the sounder. If any of the sounders does not respond to the request at least once, during the receiver supervision time, the system will regard the accessory as lost.
NOTE:
The receiver supervision time should be higher than the sounder supervision time in order to eliminate false lost event.
Range: 00-255 minutes Default: 58 minutes
NOTE:
WisDom: Engineer menu: 1) System > 1) Timers > 9) Accessory supervision time Agility: Engineer menu: 1) System > 1) Timers > TX supervision
Pre Alarm indication
This wireless sounder incorporates a pre - alarm feature that enhanc es the security of the system, by producing a local alarm in case of sabotage. If defined, the system sends a pre-alarm signal to the sounder at the beginning of the entry delay. If the sounder does not receive a cancellation signal from the system at the end of the entry time, the sounder goes into alarm mode.
NOTE:
WisDom (Ver 4.25): Engineer menu Quick key 1) System > 2)Controls > 44) Pre alarm Agility: Engineer menu [1][2] > Advanced > Sounder Pre alarm
Step 3: Testing the Sounder
Communication Test
The sounder communication test performs a communication test between the sounder receiver and the system. ¾ To perform communication test
1. Access to communication test option
NOTE:
WisDom: Engineer menu > 9) Devices > 2) Sounders > 3) Communication test Agility: Engineer menu > 2) Testing > 5) Sounder > 1) Communication test
2. The system sends a test signal to the sounders. A number between 00-99 indicates the strength of the communication signal between the system and the sounder.
NOTE:
For successful communication, the strength of the signal should be higher that the sounder receiver noise threshold level. (WisDom: Engineer menu quick key [9][2][4], Agility: Engineer menu > 2)Testing >1)Main unit > 1)Calibration).
Diagnostics
The Diagnostics menu enables to test parameters reflecting the operation of the sounder:
Ê Speaker batteries voltage: Tests the selected sounder’s speaker batteries voltage Ê Radio batteries voltage: Tests the selected sounder’s radio's batteries voltage Ê Sounder version: Displays information regarding the sounder's version
Wireless Sounder Instructions 7
NOTE:
WisDom: User menu: 4) Maintenance > 7) Sounders > 1) Diagnostics Agility: Engineer menu > 2) Testing> 5) Sounder>2) Battery test > 3)Version
The diagnostic features can be also performed from Upload/Download software, locally or remotely
Replacing Batteries
1. Before opening the sounder it is advised to silence the tamper alarm using the Tamper Mute option (see the Muting Tamper paragraph on page 6).
2. Remove the sounder cover as described in the installation section.
NOTE:
If required you can silence a tamper alarm by pressing the RESET Switch.
3. Remove the old batteries from the metal clips and replace with new ones. Pay attention to the polarity.
4. Press the RESET switch
5. Close the cover and fasten the cover locking screw.
NOTES:
Dispose of old batteries according to your local regulations. Risk of explosion if battery replaced by an incorrect type.
Technical Information
Electrical
Power Supply 5 X CR123, 3V Lithium Battery (3 batteries for the Radio
Transceiver, 2 batteries for the Speaker) Battery life 3 years (typical) Speaker sound level 105 dB @ 1 meters (adjustable) Size (HxWxD) 145 x 120 x 50 mm (5.7x4.7x2 inch) Weight (batteries not
0.44Kg (15.52 oz)
included)
Radio
Radio type Two Way Narrow band Frequency 868 MHz or 433MHz Range up to: 150m (492’) Line of sight Supervision Yes Modulation Type ASK
Environmental
Temperature - 25°C to 60°C (-4°F to 140°F) IP Rating IP 44
Environmental Class Class IV
Ordering Information
Part Number Description
WL S40 2 way Internal Wireless Sounder, 433 / 868.65 MHz
Specifications are subject to change without prior notice. Should any questions arise please contact your supplier.
Wireless Sounder Instructions 9
RTTE Compliance Statement
Hereby RISCO Group declares that this wireless sounder is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/ EC. For the CE Declaration of Conformity please refer to our website: www.riscogroup.com.
FCC Note:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential instal lation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: a) Reorient or relocate the receiving antenna. b) Increase the separation between the equipment and receiver. c) Connect the equipment to an outlet on a circuit different from that to which the
receiver is connected. d) Consult the dealer or an experienced radio/TV technician. FCC ID: JE4RWRT433 valid for model WL S40 IC: 6564A-RWRT433 valid for model WL S40
FCC Warning
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment.
RISCO Group Limited Warranty
RISCO Group Ltd. and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with pro ducts not manufactured by the Seller, Seller cannot guarantee the performance of the security system which uses this product. Seller's obligation and liability under this warranty is expressly limited to repairing and replacing, at Seller's option, within a reasonable time after the date of delivery, any product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of merchantabilit y or of fitness for any particular purpose. In no case shall seller be liable for any c ons equenti al or inc ide ntal dam ages for breac h of this or any other warranty, expressed or implied, or upon an y other basis of liability whatsoever. Seller's obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or consequential damages or delay. Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any persona; injury or prop erty loss by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection. Buyer understands that a properly installed and maintained alarm may onl y reduce the risk of burglary, robbery or fire without warning, but is not insurance or a guaranty that such will not occur or that there will be no personal injury or property loss as a result. Consequently seller shall have no liab ility for any personal injur y, property damage or loss based on a claim that the product fails to give warning. However, if seller is held liable, whether directly or indirectly, for any loss or damage arising from under this limited warranty or otherwise, regardless of cause or origin, sellers maxi mum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against seller. No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty. WARNING: This product should be tested at least once a week.
Wireless Sounder Instructions 11
Contacting RISCO Group
RISCO Group is committed to customer service and product support. You can contact us through our website www.riscogroup.com or as follows:
United Kingdom
Tel: +44-161-655-5500 technical@riscogroup.co.uk
USA Tel: +1- 631-719-4400 support-usa@riscogroup.com
Italy Tel: +39-02-66590054 support@riscogroup.it
Spain Tel: +34-91-490-2133 support-es@riscogroup.com
France Tel: +33-164-73-28-50 support-fr@riscogroup.com
Belgium Tel: +32-2522-7622 support-be@riscogroup.com
All rights reserved.
No part of this document may be reproduced in any form without prior written permission from the publisher.
© RISCO Group 07/09 5IN1260
Brazil Tel: +1-866-969-5111 support-br@riscogroup.com
China Tel: +86-21-52-39-0066 support-cn@riscogroup.com
Poland Tel: +48-22-500-28-40 support-pl@riscogroup.com
Israel Tel: +972-3-963-7777 support@riscogroup.com
Loading...