Pilz PNOZ e1p Data Sheet

Emergency Stop Relays, Safety Gate PNOZ
Category 4, EN 954-1
PNOZ e1p
Technical details PNOZ e1p
Electrical data
Supply voltage 24 VDC Tolerance 80 ... 125 % Power consumption no load: 2 W Residual Ripple DC 20 % Outputs 2 safety outputs
1 auxiliary output
Switching capability UB <26.5 V: 24 V/2 A/50 W
UB >26.5 V: 24 V/1.5 A/40 W 2 Safety outputs parallel:
24 V/3 A/80 W Voltage and current at input and reset circuits and feedback control loop 24 VDC, 5 mA
Emergency stop relay and safety gate monitor in accordance with VDE 0113-1, 11/98, EN 60204-1, 12/97 and IEC 204-1, 11/98
Features
Monitored manual or automatic reset can be selected
2 safe semiconductor outputs
1 auxiliary semiconductor out-
put
Auxiliary output can also be used as a diagnostic output
Option for detecting shorts across the input contacts
Applications in accordance with EN 954-1, 07/96, category 2, 3 or 4
Self-test after UB is supplied
Continuous self-monitoring
Regular switch-off test of the
safety outputs
Approval
auxiliary output and test pulse outputs 24 VDC/0.5 A
Times
Delay-on energisation manual reset: 180 ms
automatic reset: 100 ms Delay-on de-energisation max. 35 ms Switch-on delay Simultaneity channel 1/2 Max. Supply Interruption before max. 20 ms de-energisation
Environmental data
Storage temperature -25 ... 70 °C
Mechanical data
Max. cross section of external conductor, single core
multi-core conductor (2 conductors with identical cross section) flexible with crimp connector without
Torque setting for terminals 0.5 ... 0.6 Nm (screws) Dimensions (H x W x D) 87 x 22.5 x 121 mm Weight 170 g
3 s (on initial reset once UBis supplied)
¥
fl
exible without crimp connector:
0.2 ... 2.5 mm
flexible with crimp connector:
0.25 ... 2.5 mm
plastic sleeve: 0.25 ... 1 mm
flexible with TWIN crimp connector with
plastic sleeve: 0.5 ... 1.5 mm
1
2
2
2
2
PNOZ e1p
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland NSG-D-2-289-09/01 Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
Emergency Stop Relays, Safety Gate
Category 4, EN 954-1
PNOZ e1p
Description
22.5 mm P-99 housing, DIN-Rail mounting
Semiconductor outputs, short-circuit proof: – 2 safety outputs – 1 auxiliary output – 2 test pulse outputs
Connections for – E-STOP button – safety gate limit switch – Pressure mat, light barrier and
proximity switch evaluation devices
– Reset button
Auxiliary output can also be used as a diagnostic output It is possible to program the driver for reading diagnostic data yourself. However, the CD „PLC Drivers for PNOZelog“ is also
Internal wiring diagram
Input circuit
B
U
A2
A1
available. This contains pre­programmed drivers for the following controllers:
- SIMATIC S7
LEDs for switching status and faults in channel 1/2 and for supply voltage
Shorts across the input contacts are detected by means of test pulse outputs
Increase in the number of safety contacts available by connecting expander modules
Operating modes
Single-channel operation
Dual-channel operation
Automatic reset
Monitored manual reset
Reset circuit/ feedback control loop
S34
S12
S22
Mode
Y4
Auxiliary output
Y32
Y5
Test pulse outputs
S21
S11
Safety outputs
Power supply
&
14
24
&
&
Input circuit
µController 1
µController 2
Test pulse outputs
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland NSG-D-2-289-09/01 Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de