Parr Instrument A699VB User Manual

670M
A699VB Valve
Operation and Maintenance Instruction Manual
Operation/Caution
The A699VB Series Valve has a soft seat seal.
Note: While this type of valve seals very easily, they also have a tendency to be “overtightened” when closing during operation.
CAUTION: “Overtightening” will cause the 20VBHA Valve Seat to extrude into the valve body, pinching off the orifice of the 20VBHA Valve Seat. This may reduce flow through the valve and the 20VBHA Valve Seat may need to be replaced.
Dissasembly of the A699VB Series Valve
1. Fully open the valve by turning the bar
handle counter clockwise.
2. Loosen the packing nut by turning it counter
clockwise in relation to the valve body until it’s threads are clear of the valve body.
3. Pull the handle, needle, and packing nut out
of the valve body together.
4. Remove the washer.
5. Remove the (2) PTFE packing or (1) Grafoil
packing. Inspect these parts for wear and replace if necessary.
Assembly of the A699VB Series Valve
1. Before assembly, all parts should be clean
and in good condition.
2. Install the new valve seat into the valve
body.
3. Install the lantern ring.
4. Install the packing.
5. Install the washer.
6. Apply a small amount of molylube (Parr part
number 424HC) to the internal and external threads of the packing nut.
7. With the valve needle still in the fully open
position, (threaded fully into the packing nut) hand tighten the handle, needle, and packing nut into the valve body.
8. When the packing nut has been installed
finger tight, tighten the packing nut with a wrench an additional “three wrench flats” (1/2 turn) to pre-load the packing.
9. Again note when closing, the valve should
not be overtightened.
6. Remove the lantern ring.
7. Remove the valve seat and discard.
Parr Instrument Company www.parrinst.com
A699VB Valve
233VB
BAR HANDLE
234VB2*
PLUG TIP NEEDLE
235VB
PACKING NUT
7VBCM
WASHER, MONEL
2X 4VB3
PTFE PACKING
SEE NOTE 2
21VB*
LANTERN RING
20VBHB
VALVE SEAT
700VB*
VALVE BODY
A699VB Valve
Notes:
1) * Indicates parts required in special material
2) Substitute (1) 4VB4KL grafoil packing for high-temp
3) Optional fittings for outlet 491HC* Nipple 1/4NPTM × 1/4NPTM
or 308VB* male conn 1/4NPTM × 1/4TUBE
211 53rd Street • Moline, Illinois 61265 USA 1-309-762-7716 • 1-800-872-7720 • Fax: 1-309-762-9453
670M R00 Revision 11/06/13
P
arr Instrument Company
E-mail: parr@parrinst.com • http://www.parrinst.com
Loading...