INVERTED MICROSCOPE
CKX41/CKX31
UNIVERSAL
INFINITY SYSTEM
A new advance in routine inspections
Page 2
1
Phase-contrast
Phase-contrast
Relief contrast
Relief contrast
Incorporation of advanced UIS optics
ensures the highest level of clarity for cell checking applications.
CKX41
A binocular tilting tube, which allows observation while standing, and a trinocular observation tube which is compatible with various video cameras are available. Numerous accessories make it easy to upgrade the CKX41 according to need.
CKX31
Standard microscope for cell culture observation with fixed binocular tube.
Page 3
PHC objective minimally affected by surface tension around the container edge
The PHC objective is minimally affected by surface tension of the culture fluid, which can compromise clarity at the image periphery. Easier multi-well observation is one of several benefits. Combined with the improved flatness resulting from the use of UIS optics, this feature facilitates clear observation of cells even at the edge of the container.
PHC objective
2
Fluorescence
Fluorescence
Clear up to the edge of the view field. Flatness improved for 10 to 15%
Clear, wide-ranging phase-contrast observation. Ideal phase plate for cell culture.
Clear cell observation right to the edge of the container. PHC objective virtually unaffected by surface tension.
Enhanced clarity makes it easier to observe cell activity status
Incorporation of the world-renowned Olympus UIS optical system in the CKX series makes a dramatic improvement in flatness for 10 to 15% and enables very clear, high contrast images to be obtained up to the edge of the field view.
Adoption of a UIS phase plate optimized for cell culture observation provides higher image contrast
The UIS phase plate adjusts the contrast according to the thickness of the cell culture, producing higher contrast images than those obtainable from conventional systems.
Low magnification UIS video adapters can be used for
0.25X, 0.35X and 0.5X magnifications, enabling clear display of the complete cell on the monitor.
The UIS optics provide unsurpassed optical performance
The UIS optical system combines with the simplicity of the light path and the imaging excellence of a relay lenses to maintain the highest possible image intensity and to arrive at the highest optical correction level. Thanks to this feature, the UIS infinity-corrected optical system deliver unsurpassed resolution and contrast. In addition to improved image quality, the maximum field of view has been extended to F.N. 22. This allows the use of various observation tubes provided for upright microscopes (patented, CKX41 only).
UIS infinity-corrected optical system
The advanced Olympus UIS optical system maximized the advantages of infinity correction. Light travels through the body tube as parallel rays as it passes through the objective. These are focused by the tube lens to form a completely aberration­free intermediate image. Attachments can be added between the objective and the built-in tube lens in the observation tube without any magnification factor alterations to total magnification. Additional correction lenses are not required The UIS optical system delivers optimum image quality with any configuration.
Standard field number 20
Image capturing area 22
Maximum field number 22
General objective
Half mirror
Objective
Parallel light
Illumination light
Tube lens
Image forming ray
Primary focus plane
Reflected ray
Page 4
3
Page 5
4
Just set the specimen on the stage and observe immediately while standing, with no optical adjustments.
Pre-centered phase-contrast slider for quick, adjustment-free observation
With the pre-centered phase-contrast slider, there is no need to repeat centering each time the objective magnification is changed. Likewise, ring slit exchange when swapping between objectives is also unnecessary, since the ring slit is standardized for 10X, 20X and 40X magnifications. The CKX series makes phase-contrast observations quick and easy, without optical adjustments, for much more efficient performance of routine tasks. Since the phase plate transmission rates are dictated by the objective in use, the brightness remains constant even when the magnification is changed.
*The IX2-SL with centering mechanism enables maximized phase-contrast performance with precise optical adjustments.
Slim, compact design takes up minimum laboratory space
The slim, compact design minimizes the depth of the microscope, allowing easy installation right beside the incubator or clean bench. Specimens can be taken and immediately set on the microscope stage for quick, efficient inspection.
Easy observation at the clean bench
The tilting binocular tube combination makes it unnecessary for researchers to adopt uncomfortable postures like lowering their face to the inside of the clean bench. Simply observe down the tube while working, and raise the tube afterwards: this method is much more convenient, since the clean bench can be opened/closed without moving the microscope.
Tilting binocular tube for observation while standing
The binocular tube has a 30-60 degree tilting mechanism to let the researcher make observations while standing. The specimen is removed from the incubator and placed straight onto the microscope stage, so that cell checking can be done immediately. "Quick observation, quick return"— that’s the new style of routine inspection made possible by Olympus.
Empty slot10X, 20X, 40X4X
10X 20X 40X
Page 6
Fluorescence observation system with tree-position allows the use of U excitation.
Adopted renowned UIS optics, this system provides B and G excitations and optionally U excitation as well. All three can be provided simultaneously, with quick, easy exchange among them. Many different UIS filters can also be installed, according to requirements, enabling this system to meet a wide range of fluorescence observations needs. Also, thanks to newly developed fluorescent illuminator, which secured UV transmission rate, and a variety of
UIS fluorescent objectives, clear and high contrast fluorescent images are provided.
5
High-resolution relief contrast with N.A.0.5: thick specimens like egg cells can be observed in three dimensions
Olympus' relief contrast maintains the same shadow direction even if the magnification is changed. The two-stage exchange slider uses a common aperture for 20X and 40X magnifications, so exchange between 10X/20X and 10X/40X is performed quickly. The same feature enables easy optical adjustment: by simply using the lever, the contrast can be changed while centering is being performed.
Suitable for blood cell plates and other kinds of micro-plate
The mechanical stage offers excellent inspection performance with blood cell plates or other micro­plates.
Glass stage insert plate and warm plate
Also included are a glass stage insert plate, for simple confirmation of the objective in use, and a warm plate for easy temperature control (CKX41 only).
Relief contrast observations
Fluorescence observations
Accessories
Cost-effective digital imaging
Mounting the trinocular tube on the CKX41 makes it possible to attach the DP12 digital camera or different types of video cameras.
CKX41+DP12
Vertical installation avoids interference with manipulators
Vertical installation helps the user to avoid accidentally touching the manipulators while operating the slider or making optical adjustments.
Page 7
CKX41/CKX31 dimensions (unit: mm)
Specifications are subject to change without any obligation on the part of the manufacturer.
ISO9001
Certification
Design and production
adheres to ISO9001
international quality standard.
ISO 9001
Accredited by the Dutch Council for
Accreditation
ISO14001
Design and production at the Olympus
Optical Co. Ltd. Ina Plant conforms with
ISO14001 specifications for
environmental management systems.
Certification
ISO 14001
008
UKAS
ENVIRONMENTAL
MANAGEMENT
Item CKX41 CKX31 Optical system UIS (Universal Infinity-corrected) optical system Focus Vertical nosepiece movement (stage is fixed),
coaxial coarse and fine focus with tension adjustment mechanism, roller slide mechanism, stroke: 7mm up and 2mm down from focus position which is 1mm above the stage,
stroke per rotation: 39.6mm (coarse), 0.2mm (fine) Revolving nosepiece Quadruple Stage Plain stage 160mm(L) x 250mm(W), stage clips attachable
Exchangeable insert plate (ø25mm opening) incorporated ø35 petri dish holder stage
incorporated
Mechanical stage Right-hand low drive coaxial controls,
stage movement: X=120mm, Y=78mm, with three dish/sample holders
Substage 70(L) X180(W)mm
Illumination Light source 6V,30W halogen lamp, lamp socket (U-LS30-3-2), system built-in frosted and heat absorbing filters, detachable illuminator
Filter holder Insert up to 11mm thick with ø45mm filter, detachable Aperture diaphragm Lever type, range: from minimum ø3mm to maximum ø44mm
Slider insertion With phase slider pocket and built-in slider position click stop mechanism Condenser Detachable ultra-long working distance condenser (N.A. 0.3, W.D. 72mm) Contrast slider •Pre-centered phase-contrast: 4X, 10X/20X/40X, empty slot
Centerable phase-contrast: 4X, 10X/20X, empty slot (40X optional, pre-centered)
Centerable for Relief Contrast: 10X, 20X, 40X
Observation Binocular tube U-CBI30-2: inclined 30°, interpupillary distance range: 48-75mm, tube diopter adjustment by helicoid on left sleeve (F.N. 20)
U-BI30-2: inclined 30°, interpupillary distance range: 48-75mm, diopter adjustment by helicoid on left sleeve (F.N. 22)
Trinocular tube U-CTR30-2: inclined 30°, ring dovetail attachment,
interpupillary distance range: 48-75mm, tube length and diopter adjustment by helicoid on left sleeve Observation optical path: 50(binocular)/50(video port) (F.N. 20)
U-TR30-2: inclined 30°, ring dovetail attachment, interpupillary distance range: 48-75mm, tube length and diopter adjustment by helicoid on left sleeve Observation optical path: 50(binocular)/50(video port) (F.N. 22)
Tilting binocular CKX-TBI: variable inclination angles from 30° to 60°,
tube interpupillary distance range: 50-76mm,
diopter adjustment by helicoid on right sleeve (F.N. 20) UTBI-3: variable inclination angles from 5° to 35°, circular
mounting dovetail attachment, interpupillary distance range: 50-76mm, diopter adjustment by helicoid on right sleeve. (F.N. 22)
Fluorescent illuminator Detachable illuminator,
switchable slide (3-position: B excitation, G excitation, empty slot or U excitation)
FL light source 50W Hg
FL light shutter Available
FL field stop Available
FL cubes 2 cubes (B & G), option U
(cubes are not compartible with UIS. Filter and dichroic mirror size are same as UIS)
Filter 1 filter Eyepiece For U-CBI30-2/U-CTR30-2/CKX-TBI: WHB10X/WHB10X-H (F.N. 20) 10X (F.N.: 20)
For U-BI30-2/U-TR30-2/U/TBI3: WH10X/WH10X-H/35WH10X/
PWH10X (F.N. 22)
Power supply Continuous intensity adjustment,
built-in voltage changeover switch (100/120V, 220/240V), frequency 50/60Hz
CKX41/CKX31 specifications
Objective N.A. W.D.(mm) Remarks PLC4X 0.10 22.0 PLC10X 0.25 10.5 ACH20X 0.40 3.0 LCPLFL40X 0.60 2.6 UPLFL4XPH 0.13 17.0 PHL (for use with IX2-SL) CPL10XPH 0.25 9.8 PHC (for use with IX2-SL) PL10XPH 0.25 10.5 PH1 (for use with IX2-SL) LCACH20XPH 0.40 3.2 PHC (for use with IX2-SL) LCPLFL20XPH 0.40 6.9 PH1 (for use with IX2-SL) LCACH40X2PH 0.55 2.2 PH2 (for use with IX2-SL) LCPLFL40XPH 0.6 2.6 PH2 (for use with IX2-SL) UPLFL4XPHP* 0.13 17.0 For use with IX2-SLP CACH10XPHP* 0.25 8.8 For use with IX2-SLP LCACH20XPHP* 0.40 3.2 For use with IX2-SLP LCACH40XPHP* 0.55 2.2 For use with IX2-SLP CPL10XRC 0.25 9.5 For use with CKX-RC LCACH20XRC 0.4 2.8 For use with CKX-RC LCACH40XRC 0.55 1.9 For use with CKX-RC UPLFL4X 0.13 17 U,B,G UPLFL10X 0.3 10 U,B,G UPLFL20X 0.5 1.6 U,B,G LCPLFL20X 0.4 6.9 B,G LUCPLFL40X 0.6 2.7 - 4.0
Objective lens specifications
For brightfield
For phase-contrast
For RC
For FL
* Pre-centering objective
Fixed binocular tube, inclined 45°, interpupillary distance range: 48-75mm, diopter adjustment by helicoid on right sleeve
237.6
195
393.1
515.5
473.7
370.5
364
194.5
237.6
473.2
380.5
486.6
370.5
364