Installation instructions
Steam oven
DG 4064
DG 4064 L
To avoid the risk of accidents or
damage to the appliance it is
essential to read these
instructions before it is installed
and used for the first time.
GiZ
M.-Nr. 06 786 800
Contents
Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Appliance and building-in dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
DG 4064 in 380 mm tall housing unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
DG 4064 and AB 45-7 in 450 mm tall housing unit . . . . . . . . . . . . . . . . . . . . . . . . . 8
DG 4064 L in 380 mm tall housing unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
DG 4064 L and AB 45-7 in 450 mm tall housing unit . . . . . . . . . . . . . . . . . . . . . . 12
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Building in and connecting to services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Connection cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Plumbing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Connection to the water supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Water inlet connection hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Connection to drainage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Drain hose. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3
Safety instructions
The water inlet hose must be flushed
through before using the appliance
for the first time, and thereafter every
time the water inlet hose is re-fitted.
This is to remove any deposits which
may have collected in the inlet hose
and at the stopcock.
This steam oven must only be
installed in a suitable tall housing
unit.
The appliance must be installed at
such a height that small children
cannot reach the appliance door, which
gets hot during use.
The top edge of the appliance door
should not be above eye level. If it
is too high, you will find it difficult to
access all levels safely when putting
dishes into the oven and taking them
out, and there is a danger of food
spillages and possible scalding.
Water Authority and Building
Regulations must also be
observed.
The stopcock for the steam oven
water inlet must be located so that
it is easily accessible after the
appliance has been built in.
To ensure that the waste water is
pumped away completely, the
mains drainage outlet point should not
be positioned higher than the drain
hose outlet position on the steam oven.
The temperature of the water being
drained is approx. 80 - 90 °C.
The hoses and mains connection
cable must be fitted in such a way
that the appliance can be easily taken
out of the housing unit by a service
technician should repair work ever be
necessary.
This equipment may only be used
in mobile installations such as
ships, caravans, aircraft etc. if a risk
assessment of the installation has been
carried out by a suitably qualified
engineer.
All installation work must be carried
out by a suitably qualified
technician in strict accordance with
current local and national safety
regulations.
4
Safety instructions
A cut-out a, as illustrated below, is
required in the housing unit for
feeding the water inlet and outlet
through. This is to ensure that there is
adequate space for any movement in
the hoses during operation and thus
prevent the risk of damage to the hoses
and any subsequent water damage.
b
450
a
45
130
120
560-568
b Isolator switch position.
Important UK: Do not position the
isolator behind the appliance!
Keep these instructions in a safe place
and pass them on to any future
user/owner of the appliance.
All dimensions in this instruction booklet
are given in mm.
5
Appliance and building-in dimensions
DG 4064 in 380 mm tall housing unit
45
200 cm
2
0
555
c
d
e
f
b
i
g
a
h
500
560-568
0555
560-568
380
593-595
544
527
542
378
22
22
595
595
385
55
270
6