LS180HSV5
Single Zone High Efficiency Standard Wall Mount
Outdoor Unit (ODU) - LSU180HSV5, Indoor Unit (IDU) - LSN180HSV5
Performance: |
Operating Range: |
Cooling: |
Outdoor Unit: |
Cooling Capacity |
3,070 ~ 18,000 ~ 29,515 |
(Min~Rated~Max) (Btu/h) |
|
SEER |
21.5 |
EER |
12.58 |
SEER - Seasonal Energy Efficiency Ratio |
EER - Energy Efficiency Ratio |
Heating:
Heating Capacity |
|
(Min~Rated~Max) (Btu/h) |
3,070 ~ 21,600 ~ 38,898 |
HSPF |
10.2 |
Max. Heating @ Indoor 70°F DB |
22,340 (103%) |
Outdoor 19°F DB / 17°F WB |
|
Outdoor 6°F DB / 5°F WB |
19,300 (89%) |
Outdoor -3°F DB / -4°F WB |
16,760 (77%) |
HSPF - Heating Seasonal Performance Factor |
|
Cooling Nominal Test Conditions: |
Heating Nominal Test Conditions: |
Indoor: 80°F DB / 67°F WB |
Indoor: 70°F DB / 60°F WB |
Outdoor: 95°F DB / 75°F WB |
Outdoor: 47°F DB / 43°F WB |
Outdoor Unit:
|
MOP (A) |
20 |
|
MCA (A) |
13 |
|
Cooling / Heating Rated Amps (A) |
9.85 / 9.85 |
|
Compressor (A) |
9.6 |
|
Fan Motor (A) |
0.25 |
|
MOP - Maximum Overcurrent Protection |
MCA - Minimum Circuit Ampacity |
Total Power Input:
Cooling Power Input (kW) |
1.431 |
Heating Power Input (kW) |
1.73 |
|
|
Piping:
Liquid Line (in., O.D.) |
ø3/8 |
Vapor Line (in., O.D.) |
ø5/8 |
Additional Refrigerant (oz./ft.) |
0.38 |
Min. / Max. Pipe Length (ft.)² |
9.8 / 114.8 |
Piping Length (no add’l refrig., ft.) |
24.6 |
Max. Elevation (ft.) |
49.2 |
Controls Features:
• 24-Hour on/o timer |
• Condensate Sensor |
• Self-cleaning indoor coil |
• 4-Way auto swing |
Connection |
• Sleep mode |
• Auto changeover |
• Inverter (variable speed |
• Cooling only function |
• Auto restart |
compressor) |
• Built-in Wi-Fi via Smart |
• Jet cool/Jet heat |
• IDU compatible with |
ThinQ app |
• Built-in low ambi- |
Multi F ODUs |
• Built-in base pan heater |
ent standard, down to |
• Smart Diagnosis |
(9/12k; optional for 18k) |
14°F (cooling mode) |
• 3M Micro Filter |
|
Cooling (°F DB) |
14 ~ 118 |
Heating (°F WB) |
-4 ~ +65 |
Indoor Unit: |
|
Cooling (°F WB) |
53 ~ 75 |
Heating (°F DB) |
60 ~ 86 |
Electrical: |
|
Power Supply (V¹/Hz/Ø) |
208-230/60/1 |
|
|
System Data: |
|
|
|
Refrigerant Type |
R410A |
Refrigerant Control |
EEV |
Refrigerant Charge (lbs.) |
3.53 |
ODU Sound Pressure |
|
(Cooling / Heating) (±3 dB[A])³ |
53 / 53 |
IDU Sound Pressure |
|
Cooling(H/M/L/Sleep)(±3dB[A])³ |
45 / 40 / 35 / 29 |
Heating (H/M/L) (±3 dB[A])³ |
45 / 40 / 35 |
ODU Net / Shipping Weight (lbs.) |
116.8 / 126.5 |
IDU Net / Shipping Weight (lbs.) |
25.6 / 32.2 |
Heat Exchanger Coating |
GoldFin™ |
|
|
Fan: |
|
ODU Type |
Propeller |
IDU Type |
Cross Flow |
Fan Speeds (Fan/Cool/Heat) |
6 / 6 / 6 |
Quantity (ODU + IDU) |
1 + 1 |
Motor/Drive |
Brushless Digitally Controlled/Direct |
ODU Max. Air Flow Rate (CFM) |
2,119 |
IDU Air Flow |
|
Cooling, Max/H/M/L (CFM) |
706 / 530 / 477 / 371 |
Heating, Max/H/M/L (CFM) |
706 / 547 / 494 / 371 |
Dehumidification (pts./hr.) |
5.5 |
Notes:
1. Acceptable operating voltage: 187V-253V.
2. Piping lengths are equivalent.
3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied and must be a minimum of four-conductor, 18 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes.
5. See Engineering Manual for sensible and latent capacities.
6. Power wiring cable size must comply with the applicable local and national code.
7. The indoor unit comes with a dry helium charge.
8. This data is rated 0 ft. above sea level, with 24.6 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor units.
9. Must follow installation instructions in the applicable LG installation manual.
10. Multi compatible 18k IDUs include socket adapters for refrigerant pipe connections with Multi F systems.
BACnet® is a registered trademark of ASHRAE. LonWorks® is a trademark of Echelon Corporation.
Optional Accessories:
MultiSITE™ CRC1 - PREMTBVC0 |
AC Smart IV BACnet® Gateway - |
|
|
MultiSITE CRC1+ - PREMTBVC1 |
PBACNA000 |
|
|
MultiSITE Comm. Mgr. - PBACNBTR0A |
ACP IV BACnet Gateway - PQNFB17C2 |
|
|
PI-485 - PMNFP14A1 |
Base Pan Heater for 18k - PQSH1201 |
|
|
Dry Contact - PDRYCB300 |
Low Ambient Wind Baffle Kit (Cooling |
|
|
LonWorks® Gateway - PLNWKB100 |
to 0°F) - ZLABGP02A |
|
|
|
|
|
|
For a complete list of available accessories, contact your LG representative. |
SB_SZ_HiEff_Std_WallMount_LS180HSV5_2018_03_20_055632 |
||
For continual product development, LG reserves the right to change specifications without notice. |
|||
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com |