Job Name/Location: |
|
|
|
|
|
|
|
|
|
Tag #: |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Date: |
|
|
|
|
For: |
File |
Resubmit |
|
|
|
|||||
PO No.: |
|
|
|
|
|
Approval |
Other |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Architect: |
|
|
|
|
GC: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Engr: |
|
|
|
|
Mech: |
|
|
|
|
|
|
|
|
|
|
Rep: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(Company) |
|
|
|
(Project Manager) |
|
|
|
|
|
|
|
||||
|
LS120HSV4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
High Efficiency Single Zone Inverter |
|
|
|
|
|
|
|
|
|
|
|
|
||
Outdoor Unit (ODU) - LSU120HSV4 |
Indoor Unit (IDU) - LSN120HSV4 |
|
|
|
|
|
|
|
|||||||
Performance: |
|
|
|
|
|
|
|
|
Operating Range: |
|
|
||||
Cooling: |
|
|
|
|
|
|
|
|
Outdoor Unit: |
|
|
|
|||
|
Cooling Capacity (Min~Rated~Max) (Btu/h) |
1,023~11,200~13,785 |
|
|
|
Cooling (°F DB) |
14-118 |
||||||||
|
SEER |
|
|
|
|
|
21.5 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
Heating (°F WB) |
-4-65 |
|||||
|
EER |
|
|
|
|
|
12.5 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
Indoor Unit: |
|
|
|
||
SEER - Seasonal Energy Efficiency Ratio EER - Energy Efficiency Ratio |
|
|
|
|
|
|
|
|
|||||||
Heating: |
|
|
|
|
|
|
|
|
|
Cooling (°F WB) |
53-75 |
||||
|
|
|
|
|
|
|
|
|
|
|
|||||
|
Heating Capacity (Min~Rated~Max) (Btu/h) |
1,023~13,300~22,178 |
|
|
|
Heating (°F DB) |
60-86 |
||||||||
|
HSPF |
|
|
|
|
|
11.0 |
|
|
Unit Data: |
|
|
|
||
HSPF - Heating Seasonal Performance Factor |
|
|
|
|
|
|
|
Refrigerant Type |
R410A |
||||||
Cooling Nominal Test Conditions: |
Heating Nominal Test Conditions: |
|
|
|
|
||||||||||
|
Indoor: 80°F DB/67°F WB |
Indoor: 70°F DB/60°F WB |
|
|
|
|
Refrigerant Control |
|
EEV |
||||||
|
Outdoor: 95°F DB/75°F WB |
Outdoor: 47°F DB/43°F WB |
|
|
|
|
Refrigerant Charge (lbs) |
2.21 |
|||||||
Electrical: |
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
ODU Sound Pressure (±3 dB(A))³ |
45 |
|||||
|
Power Supply (V¹/Hz/Ø) |
208-230/60/1 |
|
|
|
IDU Sound Pressure (H/M/L/Sleep) (±3 dB(A))³ |
39/33/23/19 |
||||||||
Outdoor Unit: |
|
|
|
|
|
|
|
|
|
ODU Net Unit Weight (lbs) |
75 |
||||
|
|
|
|
|
|
|
|
|
ODU Shipping Weight (lbs) |
79 |
|||||
|
|
|
|
|
|
|
|
|
|
|
|||||
|
MOP (A) |
|
|
|
|
|
15 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
IDU Net Unit Weight (lbs) |
20 |
|||||
|
MCA (A) |
|
|
|
|
|
10 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
IDU Shipping Weight (lbs) |
26 |
|||||
|
Cooling Rated Amps (A) |
|
|
|
8.7 |
|
|
|
|||||||
|
|
|
|
|
|
|
Heat Exchanger Coating |
GoldFin™ |
|||||||
|
Heating Rated Amps (A) |
|
|
|
8.7 |
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
Compressor (A) |
|
|
|
|
|
8.3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fan: |
|
|
|
|||
|
Fan Motor (A) |
|
|
|
|
|
0.40 |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
ODU Type |
|
Propeller |
||||
MOP - Maximum Overcurrent Protection MCA - Minimum Circuit Ampacity |
|
|
|
|
|
||||||||||
Total Power Input: |
|
|
|
|
|
|
|
|
|
IDU Type |
|
Cross Flow |
|||
|
|
|
|
|
|
|
|
|
|
|
Fan Speeds (Fan/Cooling/Heating) |
6/6/6 |
|||
|
Cooling Power Input (kW) |
|
|
|
0.90 |
|
|||||||||
|
|
|
|
|
|
|
Quantity (ODU + IDU) |
1 + 1 |
|||||||
|
Heating Power Input (kW) |
|
|
|
1.0 |
|
|
|
|||||||
|
|
|
|
|
|
|
Motor/Drive |
Brushless Digitally Controlled/Direct |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|||||
Piping: |
|
|
|
|
|
|
|
|
|
ODU Max Air Flow Rate (CFM) |
1,165 |
||||
|
|
|
|
|
|
|
|
|
|
|
IDU Air Flow H/M/L (CFM) |
353/272/191 |
|||
|
Liquid Line (in, OD) |
|
|
|
|
|
1/4 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
Dehumidification (pts/hr) |
2.3 |
|||||
|
Vapor Line (in, OD) |
|
|
|
|
|
3/8 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Additional Refrigerant (oz/ft) |
|
|
|
0.22 |
|
|
Notes: |
|
|
|
||||
|
Min/Max Pipe Length (ft)² |
|
|
|
6.6/65.6 |
|
|
|
|
|
|||||
|
|
|
|
|
|
1.Acceptable opera ng voltage: 187V-253V. |
|
|
|||||||
|
Piping Length (no add'l refrigerant, ft) |
|
|
|
41.0 |
|
|
2.Piping lengths are equivalent. |
|
|
|||||
|
|
|
|
|
|
3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. |
|
|
|||||||
|
Max Elevation (ft) |
|
|
|
|
|
32.8 |
|
|
4.All communica on/power cable to be minimum 18 AWG, 4-conductor, stranded, |
|
|
|||
|
|
|
|
|
|
|
|
shielded and must comply with applicable local and national code. |
|
|
|||||
|
|
|
|
|
|
|
|
|
|
5.See Engineering Manual for sensible and latent capaci es. |
|
|
|||
Controls Features: |
|
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
6.Power wiring cable size must comply with the applicable local and na onal code. |
|
|
|||||
•24-Hour on/o mer |
•Chaos wind |
|
|
•Jet cool/Jet heat |
|
7.The indoor unit comes with a dry helium charge. |
|
|
|||||||
•4-Way auto swing |
•Condensate Sensor |
|
|
•3M Micro Protection Filter |
|
8.This data is rated 0 |
above sea level, with 24.6 of refrigerant line and a 0 level |
|
|
||||||
|
|
|
difference between outdoor and indoor units. |
|
|
||||||||||
•Auto changeover |
Connection |
|
|
•Self-cleaning indoor coil |
|
|
|
||||||||
|
|
|
9.Must follow installa on instruc ons in the applicable LG installa on manual. |
|
|
||||||||||
•Auto restart |
•Energy saving |
|
|
•Sleep mode |
|
|
|
|
|
|
|
||||
•Built-in low ambient |
•Inverter (variable speed |
|
|
•Cooling only func on |
|
|
|
|
|
|
|
||||
standard, down to 14°F |
compressor) |
|
|
•Smart AC module |
|
|
|
|
|
|
|
||||
(cooling mode) |
•IDU compatible with Multi F |
|
|
|
|
|
|
|
|
|
|||||
|
|
ODUs |
|
|
|
|
|
|
|
|
|
|
|
|
|
Optional Accessories (sold separately) |
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
LG Programmable Thermostat - PREMTB10U |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
PI-485 - PMNFP14A0 |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
Low Ambient Wind Baffle (Cooling operation to 0°F) - ZLABGP01A |
|
|
|
|
|
|
|
|||||||
For a complete list of available accessories, contact your LG representative. |
|
|
|
|
|
|
|
|
|
||||||
For continual product development, LG reserves the right to change specifications without notice. |
|
|
|
|
|
|
|
||||||||
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com |
SB-SZ-HighEfficiencyInverter-LS120HSV4-01-15 |
Page 1 of 3 |