Job Name/Location: |
|
|
|
|
Tag #: |
|
|
|
|
|
|
Date: |
|
For: |
File |
Resubmit |
|
PO No.: |
|
|
Approval |
Other |
|
|
|
|
|
|
|
Architect: |
|
GC: |
|
|
|
|
|
|
|
|
|
Engr: |
|
Mech: |
|
|
|
Rep: |
|
|
|
|
|
(Company) |
(Project Manager) |
|
|
LS090HEV1
Mega 220V Single Zone Inverter
Outdoor Unit (ODU) LSU090HEV1 Indoor Unit (IDU) LSN090HEV1
Performance:
Cooling:
Capacity (Min/Rated/Max) (Btu/h) |
3,070~8,500~9,500 |
|
SEER |
|
19.0 |
EER |
|
12.5 |
|
|
|
SEER Seasonal Energy Efficiency Ratio |
EER Energy Efficiency Ratio |
|
Heating: |
|
|
|
|
|
Capacity (Min/Rated/Max) (Btu/h) |
3,070~9,000~10,500 |
|
HSPF |
|
9.0 |
|
|
|
HSPF Heating Seasonal Performance Factor |
|
|
Cooling Nominal Test Conditions: |
Heating Nominal Test Conditions: |
|
Indoor: 80°F DB/67°F WB |
Indoor: |
70°F DB/60°F WB |
Outdoor: 95°F DB/75°F WB |
Outdoor: 47°F DB/43°F WB |
|
Electrical: |
|
|
|
|
|
Power Supply (V¹/Hz/Ø) |
|
208 230/60/1 |
|
|
|
Outdoor Unit:
MOP (A) |
15 |
MCA (A) |
10 |
Cooling Rated Amps (A) |
7.5 |
Heating Rated Amps (A) |
7.5 |
Compressor (A) |
7.0 |
Fan Motor (A) |
0.5 |
MOP Maximum Overcurrent Protection MCA Minimum Circuit Ampacity
Total Power Input:
Cooling Power Input (kW) |
0.68 |
Heating Power Input (kW) |
0.78 |
Piping:
Liquid Line (in, OD) |
1/4 |
Vapor Line (in, OD) |
3/8 |
Additional Refrigerant (oz/ft) |
0.22 |
Max Pipe Length (Min/Max) (ft)² |
9.8/49.2 |
Piping Length (no add'l refrigerant, ft) |
24.6 |
Max Elevation (ft) |
22.9 |
Controls Features:
•24 Hour on/o mer •2 Way (up/down) auto swing
•Auto changeover •Auto restart •Condensate sensor connection
•Energy saving •Inverter (variable speed compressor)
•Jet cool/Jet heat •Self cleaning indoor coil •Sleep mode
•Ultra quiet opera on
Operating Range:
Outdoor Unit:
Cooling (°F DB) |
|
14 118 |
|
Heating (°F WB) |
|
14 65 |
|
|
|
|
|
Indoor Unit: |
|
|
|
Cooling (°F WB) |
|
53 75 |
|
Heating (°F DB) |
|
60 86 |
|
Unit Data: |
|
|
|
Refrigerant Type |
|
R410A |
|
Refrigerant Control |
|
EEV |
|
Refrigerant Charge (lbs) |
|
1.87 |
|
ODU Sound Pressure (±3 dB(A))³ |
47 |
||
IDU Sound Pressure ±3 (H/M/L/Sleep) dB(A)³ |
39/33/25/19 |
||
ODU Net Unit Weight (lbs) |
|
62 |
|
ODU Shipping Weight (lbs) |
|
67 |
|
IDU Net Unit Weight (lbs) |
|
17 |
|
IDU Shipping Weight (lbs) |
|
20 |
|
Heat Exchanger Coating |
|
GoldFin™ |
|
|
|
|
|
Fan: |
|
|
|
ODU Type |
|
|
Propeller |
IDU Type |
|
|
Cross Flow |
Fan Speeds (Fan/Cooling/Heating) |
4/4/4 |
||
Quantity (ODU + IDU) |
208 230/60/1 |
1 + 1 |
|
|
|||
Motor/Drive |
|
Brushless Digitally Controlled/Direct |
|
ODU Max Air Flow Rate (CFM) |
953 |
||
IDU Air Flow Rate H/M/L (CFM) |
276/226/177 |
||
Dehumidification (pts/hr) |
|
2.12 |
|
|
|
|
|
Notes: |
|
|
|
1.Acceptable opera |
ng voltage: 187V 253V. |
|
2.Piping lengths are equivalent.
3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
4.All power/communica on cable to be minimum 18 AWG, 4 conductor, stranded, shielded and must comply with applicable local and national code.
5.See Engineering Manual for sensible and latent capaci es.
6.Power wiring cable size must comply with the applicable local and na onal code. 7.The indoor unit comes with a dry helium charge.
8.This data is rated 0 |
above sea level, with 24.6 of refrigerant line and a 0 level di erence |
between outdoor and indoor units. |
|
9.Must follow installa |
on instruc ons in the applicable LG installa on manual. |
For continual product development, LG reserves the right to change specifications without notice. |
SB SZ Mega220 LS090HEV1 4 15 |
Page 1 of 3 |
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com. |