LG Electronics DLEX8000V, DLGX8001V, DLGX8001W, DLEX8000W User Manual

4 (1)

FrANÇAiS ESpAÑOL ENGLiSH

OWNER’S mANuAL

DrYer

Before beginning installation, read these instructions carefully. this will simplify installation and ensure that the dryer is installed correctly and safely. leave these instructions near the dryer after installation for future reference.

Dlex8000W DlGx8001W

Dlex8000V DlGx8001V

P/No. : mFL62512869

www.lg.com

2 TABLE OF CONTENTS

TABLE OF CONTENTS

3

special features

36

Special functions

37

Custom program

 

 

 

 

 

 

4

IMPORTANT SAFETY INSTRUCTIONS

37

Steam functions

39

Steam cycle guide

 

 

 

 

 

 

4

What to Do if You Smell Gas

40 MAINTENANCE

5

Basic Safety Precautions

 

 

 

5

California Safe Drinking Water and Toxic

40

Regular cleaning

 

Enforcement Act

 

 

 

6

Grounding Instructions

41

TROUBLESHOOTING

6

Safety Instructions for Installation

 

 

 

41

Before calling for service

7

Safety Instructions for Steam Functions

8

Safety Instructions for Connecting

43

 

 

Electricity

SPECIFICATIONS

9

INTRODUCING YOUR DRYER

 

 

 

44

USING SMARTDIAGNOSISTM

 

 

9

Parts

 

 

 

 

 

 

9

Accessories

45

OPTIONAL ACCESSORIES

10

Control panel features

11

Time and status display

 

 

 

45

Stacking kit installation

 

 

 

12

INSTALLATION INSTRUCTIONS

47

WARRANTY

 

 

 

12

Installation steps

 

 

 

 

 

 

13

Installation location requirements

 

 

 

13

Clearances

 

 

 

15Installation with optional pedestal base or stacking kit

16Leveling the dryer

17To remove the door

18To install the door

19Changing the dryer vent location

20Venting requirement

22 Connecting gas dryers

24 Connecting electric dryers

29Special requirements for manufactured or mobile homes

29Final installation check

30Installation test (Exhaust check)

32 HOW TO USE

32Operating the dryer

33Cycle guide

34Sorting load

34 Loading the dryer

34Check the lint filter before every load

35Cycle setting buttons

SPECIAL FEATURES 3

SPECIAL FEATURES

LARGEST Premium Size

The ultra-large stainless steel drum offers superior durability.

EASY-ACCESS REVERSIBLE DOOR

The wide-opening door provides easy access for loading and unloading. The door hinge can be reversed to adjust for installation location.

STEAM FUNCTIONS

LG’s steam technology allows you to inject fabrics with a swirling jet of hot steam to refresh clothes, reduce static, simplify ironing and assist in the removal of lightly stained spots. Simply select the STEAM FRESH™ or SpotClean™ cycle, or you can add a Steam option to select cycles.

SMARTDIAGNOSIS™

Should you experience any technical difficulty with your dryer, it has the capability of transmitting data via your telephone to the Customer Information Center. The call center agent records the data transmitted from your machine and uses it to analyze the issue, providing a fast and effective diagnosis.

FLOW SENSE™ DUCT BLOCKAGE SENSING SYSTEM INDICATOR

The FLOW SENSE™ duct blockage sensing system detects and alerts you to blockages in the ductwork that reduce exhaust flow from the dryer. Clean exhaust systems increase efficiency and reduce drying times.

EASY-TO USE CONTROL PANEL

Rotate the cycle selector knob to select the desired dry cycle. Add cycle options or adjust settings with the touch of a button.

ENGL SHI

 

S

E

D

 

C

I

G

N

Protocol P154

Sanitization Performance of Residential Clothes dryer

4 IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

wWarning

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.

Your Safety and the safety of others it is very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

w

This is the safety alert symbol.

 

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word DANGER, WARNING or CAUTION. These words mean:

wDANGER

You will be killed or seriously injured if you don’t immediately follow instructions.

wWarning

You can be killed or seriously injured if you don’t follow instructions.

wcaution

You may be slightly injured or cause damage to the product if you do not follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

Do not install a clothes dryer with flexible plastic venting materials. If flexible metal (foil type) duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint.These conditions will obstruct clothes dryer airflow and increase the risk of fire.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this appliance or any other appliances.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

Install the clothes dryer according to the manufacturer’s instructions and local codes.

Save these instructions.

WHATTO DO IFYOU SMELL GAS:

1.Do not try to light a match or cigarette, or turn on any gas or electrical appliance.

2.Do not touch any electrical switches. Do not use any phone in your building.

3.Clear the room, building, or area of all occupants.

4.Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions carefully.

5.If you cannot reach your gas supplier, call the fire department.

IMPORTANT SAFETY INSTRUCTIONS 5

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

wWarning

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.

BASIC SAFETY PRECAUTIONS

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Read all instructions before using the dryer.

Before use, the dryer must be properly installed as described in this manual.

Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.

Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.

Do not reach into the dryer if the drum or any other part is moving.

Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Manual or in published user-repair instructions that you understand and have the skills to carry out.

Do not tamper with controls.

Before the dryer is removed from service or discarded, remove the door to the drying compartment.

Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.

Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.

Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.

Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.

The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.

Do not install or store the dryer where it will be exposed to the weather.

Always check the inside of the dryer for foreign objects.

Clean lint screen before or after each load.

Do not store plastic, paper, or clothing that may burn or melt on top of the dryer during operation.

California Safe DrinkingWATER andToxic Enforcement Act

This act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects, or other reproductive harm and requires businesses to warn customers of potential exposure to such substances.

Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde, and soot, caused primarily by the incomplete combustion of natural gas or LP fuels.

Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be minimized further by properly venting the dryer to the outdoors.

ENGL SHI

6 IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

wWarning

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance must be equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Do not modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician. This appliance must be connected to a grounded metal, permanent wiring system or an equipment-grounding conductor must be

run with the circuit conductors and connected to the equipmentgrounding terminal or lead on the appliance.

Electric shock can result if the dryer is not properly grounded.

wWarning

Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt that the appliance is properly grounded.

SAFETY INSTRUCTIONS FOR INSTALLATION

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Properly ground dryer to conform with all governing codes and ordinances. Follow details in the installation instructions. Electric shock can result if the dryer is not properly grounded.

Before use, the dryer must be properly installed as described in this manual. Electric shock can result if the dryer is not properly grounded.

Install and store the dryer where it will not be exposed to temperatures below freezing or exposed to the weather.

All repairs and servicing must be performed by an authorized servicer unless specifically recommended in this Owner’s Manual. Use only authorized factory parts. Failure to follow this warning can cause serious injury, fire, electric shock, or death.

To reduce the risk of electric shock, do not install the dryer in humid spaces. Failure to follow this warning can cause serious injury, fire, electric shock, or death.

Connect to a properly rated, protected, and sized power circuit to avoid electrical overload. Improper power circuit can melt, creating electric shock and/or fire hazard.

Remove all packing items and dispose of all shipping materials properly. Failure to do so can result in death, explosion, fire, or burns.

Place dryer at least 18 inches above the floor for a garage installation. Failure to do so can result in death, explosion, fire, or burns.

Keep all packaging from children. Packaging material can be dangerous for children. There is a risk of suffocation.

Do not install near another source of heat such as a stove, cooking oven. Failure to do so can cause deform, smoke and fire.

Do not place candles, smoking materials, or other flammables on top of the product. Dripping wax, smoke, or fire can result.

Remove all protective vinyl film from the product. Failure to do so can cause product damage, smoke or fire.

IMPORTANT SAFETY INSTRUCTIONS

7

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

wWarning

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.

SAFETY INSTRUCTIONS FOR INSTALLATION

wWarning

To reduce the risk of injury to persons, follow all industry recommended safety procedures including the use of long sleeved gloves and safety glasses. Failure to follow all of the safety warnings in this manual could result in property damage, injury to persons or death.

Exhaust/Ducting:

Gas dryers MUST be exhausted to the outside. Failure to follow these instructions can result in fire or death.

The dryer exhaust system must be exhausted to the outside of the dwelling. If the dryer is not exhausted outdoors, some fine lint and large amounts of moisture will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard.

Use only rigid metal or flexible metal 4-inch diameter ductwork inside the dryer cabinet or for exhausting to the outside. Use of plastic or other combustible ductwork can cause a fire. Punctured ductwork can cause a fire if it collapses or becomes otherwise restricted in use or during installation.

Ductwork is not provided with the dryer, and you should obtain the necessary ductwork locally.The end cap should have hinged dampers to prevent backdraft when the dryer is not in use. Failure to follow these instructions can result in fire or death.

The exhaust duct must be 4 inches (10.2 cm) in diameter with no obstructions.The exhaust duct should be kept as short as possible. Make sure to clean any old ducts before installing your new dryer. Failure to follow these instructions can result in fire or death.

Rigid or semi-rigid metal ducting is recommended for use between the dryer and the wall. In special installations when it is impossible to make a connection with the above recommendations, a UL-listed flexible metal transition duct may be used between the dryer and wall connection only. The use of this ducting will affect drying time. Failure to follow these instructions can result in fire or death.

DO NOT use sheet metal screws or other fasteners which extend into the duct that could catch lint and reduce the efficiency of the exhaust system. Secure all joints with duct tape. For complete details, follow the Installation Instructions. Failure to follow these instructions can result in fire or death.

SAFETY INSTRUCTIONS FOR STEAM FUNCTIONS

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Do not open the dryer door during steam cycles. Failure to follow these instructions can result in a burn hazard.

Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode. Failure to follow these instructions can result in fire or death.

Do not fill the steam feeder with gasoline, dry-cleaning solvents, or other flammable or explosive substances. Failure to follow these instructions can result in fire or death.

Do not touch the steam nozzle in the drum during or after the steam cycle. Failure to follow these instructions can result in a burn hazard.

Do not fill the steam feeder with hot water (over 86 ˚F/30 ˚C).

Failure to follow these instructions can result in a burn hazard.

ENGL SHI

8 IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

wWarning

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.

SAFETY INSTRUCTIONS FOR CONNECTING ELECTRICITY

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Do not, under any circumstances, cut or remove the ground prong from the power cord. To prevent injury to persons or damage to the dryer, the electrical power cord must be plugged into a properly grounded outlet.

For personal safety, this dryer must be properly grounded.

Failure to do so can result in electric shock or injury.

Refer to the installation instructions in this manual for specific electrical requirements for your model. Failure to follow these instructions can create an electric shock hazard and/or a fire hazard.

This dryer must be plugged into a properly grounded outlet. Electric shock can result if the dryer is not properly grounded. Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Failure to follow these instructions can create an electric shock hazard and/or a fire hazard.

The dryer should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate. This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

Never unplug your dryer by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet. The power cord can be damaged, resulting in a risk of fire and electric shock.

Repair or replace immediately all power cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end. The power cord can melt, creating an electric shock and/or fire hazard.

When installing or moving the dryer, be careful not to pinch, crush, or damage the power cord. This will prevent injury and prevent damage to the dryer from fire and electric shock.

SAVETHESE INSTRUCTIONS

LG Electronics DLEX8000V, DLGX8001V, DLGX8001W, DLEX8000W User Manual

INTRODUCING YOUR DRYER 9

INTRODUCING YOUR DRYER

Parts

Reversible

door

Control panel

Power Cord

Terminal Block

 

Location

Access Panel

 

(Gas Models)

(Electric

Models)

 

Lint filter

Gas

Exhaust Duct

 

Outlet

 

Connection

 

 

Leveling feet

 

Location

 

 

(Gas Models)

 

 

 

 

Accessories

Included Accessories

Optional Accessories

ENGL SHI

Drying Rack

Pedestal

Stacking Kit

 

(sold separately)

(sold separately)

NOTE

Contact LG Customer Service at 1-800-243-0000 (1-888-542-2623 in Canada) if any accessories are missing.

For your safety and for extended product life, use only authorized components.The manufacturer is not responsible for product malfunction or accidents caused by the use of separately purchased unauthorized components or parts.

The images in this Manual may be different from the actual components and accessories, and are subject to change by the manufacturer without prior notice for product improvement purposes.

10 INTRODUCING YOUR DRYER

Control panel features

wWARNING: To reduce the risk of fire, electric shock, or injury to persons, read this entire manual, including the Important Safety Instructions, before operating this dryer.

 

 

 

Cycle Selector Knob

LED Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Button

Start/Pause

Dry Level

Temp.

Time Dry

Signal

 

Button

Button

Control

Button

Button

 

 

 

Button

 

 

Operation

 

Button

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy POWER ON/OFF BUTTONN

 

 

 

 

 

 

 

- Press to turn the dryer ON or OFF. Pressing the POWER button during a cycle will cancel that cycle and any

 

 

 

 

 

 

 

 

 

 

 

 

 

 

settings will be lost.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy CYCLE SELECTOR KNOB

 

 

 

 

 

 

 

- Turn this knob to select the desired cycle. Once the desired cycle has been selected, the standard presets

 

 

 

 

 

 

 

will be shown in the display. On MANUAL DRY cycles, these settings can be adjusted using the cycle setting

 

 

 

 

 

 

 

buttons anytime before starting the cycle.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy START/PAUSE BUTTON

 

 

 

 

 

 

 

- Press this button to START the selected cycle. If the dryer is running, use this button to PAUSE the cycle

 

 

 

 

 

 

 

without losing the current settings.

 

 

 

 

 

 

 

NOTE : If you do not press the START/PAUSE button to resume a cycle within 4 minutes, the dryer turns off

 

 

 

 

 

 

 

automatically.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy MORETIME/LESSTIME BUTTONS

 

 

 

 

 

 

 

- To adjust the drying time, use these buttons with MANUAL DRY, TIME DRY, and STEAM FRESH™ cycles, as

 

 

 

 

 

 

 

well as the REDUCE STATIC and EASY IRON options. Press the MORE TIME button to increase the selected

 

 

 

 

 

 

 

manual cycle time by a minute; press LESS TIME to decrease the cycle time by a minute.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy CYCLE SETTING BUTTONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Use these buttons to adjust the settings for the selected cycle.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy OPTION BUTTONS

 

 

 

 

 

 

 

- The OPTION buttons allow you to select additional cycle options. Not all settings are available for all cycles.

 

 

 

 

 

 

 

Refer to the CYCLE GUIDE section of the manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy STEAM FUNCTIONS

 

 

 

 

 

 

 

- LG’s steam technology allows you to inject fabrics with a swirling jet of hot steam to refresh clothes, reduce

 

 

 

 

 

 

 

 

 

 

 

 

 

 

static, and make ironing easier. Simply select the steam fresh™ cycle, or add a STEAM option to the

 

 

 

 

 

 

 

selected cycles.

 

 

 

 

 

 

 

 

INTRODUCING YOUR DRYER 11

Time and status display

Time and status display shows the settings, estimated time remaining, options, and status messages for your dryer. When the dryer is turned on, the light in the display will illuminate.

ENGL SHI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Button

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy EstimatedTime Remaining

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-When the START/PAUSE button is pressed, the dryer will display the estimated (SENSOR DRY) or set time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TIME DRY) remaining, and begin tumbling.

 

 

 

 

 

 

 

NOTE :The cycle time on SENSOR DRY cycles may fluctuate as the dryer recalculates drying time for optimal

 

 

 

 

 

 

 

 

results.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy CYCLE COMPLETION INDICATORWITH CHECK FILTER REMINDER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-This portion of the display shows which stage of the drying cycle is currently underway (CHECK FILTER,

 

 

 

 

 

 

 

DRYING, COOLING, orWRINKLE CARE).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy Child Lock Indicator

 

 

 

 

 

 

 

-When CHILD LOCK is set, the CHILD LOCK indicator will appear and all buttons are disabled except the

 

 

 

 

 

 

 

POWER button. This prevents children from changing settings while the dryer is operating.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy Check FILTER reminder

 

 

 

 

 

 

 

-The display will show CHECK FILTER when the dryer is turned on as a reminder to check the filter. It turns off

 

 

 

 

 

 

 

when the START/PAUSE button is pressed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy CUSTOM PROGRAM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Custom Program allows you to store a customized dry cycle for future use. It allows you to save favorite

 

 

 

 

 

 

 

temperature, dry level, and other options for a cycle, and then recall them at the touch of a button.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy FLOW SENSE™ DUCT BLOCKAGE SENSING SYSTEM INDICATOR

 

 

 

 

 

 

 

- The FLOW SENSE™ duct blockage sensing system detects and alerts you to blockages in the ductwork that

 

 

 

 

 

 

 

reduce exhaust flow from the dryer. This improves operating efficiency and helps minimize service calls,

 

 

 

 

 

 

 

saving you money.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation steps

Checking and choosing

Leveling the dryer

Venting the Dryer

the proper location

 

 

 

120V

240V(USA)

 

 

230V(CANADA)

Connecting Gas Dryers

Plugging in the power

cord and grounding

(Gas Dryer Type)

 

Exhaust check test

Test run

(Refer to page 30.)

 

INSTALLATION INSTRUCTIONS 13

Installation location requirements

wWarning

Read all installation instructions completely before installing and operating your dryer! It is important that you review this entire manual before installing and using your dryer. Detailed instructions concerning electrical connections, gas connections, and exhaust requirements are provided on the following pages.

• A location that allows for proper exhaust installation. A

• A sturdy floor to support the total dryer weight of 200 lbs (90.7

gas dryer must be exhausted to the outdoors. See Venting

kg).The combined weight of a companion appliance should also

Requirements(P.20).

be considered.

• A grounded electrical outlet located within 2 ft. (61 cm) of either

• No other fuel-burning appliance can be installed in the same

side of the dryer. See Electrical Requirements(P.24).

closet as a dryer.

Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.

NOTE

A level floor with a maximum slope of 1 inch (2.5 cm) under entire dryer. If slope is greater than 1 inch (2.5 cm), install the Extended Dryer Feet Kit. Clothes may not tumble properly, and automatic sensor cycles may not operate correctly if dryer is not level.

For a garage installation, you will need to place the dryer at least 18 inches (46 cm) above the floor. If using a pedestal, you will need 18 inches (46 cm) to the bottom of the dryer.

Clearances

 

14" max.*

 

(35.6 cm)

 

18" min.*

 

(45.7 cm)

1"*

32.1"

5"**

(2.5 cm) (81.4 cm) (12.7 cm)

 

14" max.*

 

(35.6 cm)

 

18" min.*

 

(45.7 cm)

1"*

32.1"

5"**

(2.5 cm)

(81.4 cm)

(12.7 cm)

48 in.2*

(310 cm2)

24 in.2*

(155 cm2)

3"*

 

 

 

 

(7.6 cm)

 

 

 

 

 

 

0"

 

 

 

 

(0 cm)

 

 

 

 

40.8"

 

 

 

 

(103.6 cm)

 

 

3"*

 

1"

29"

1"

(7.6 cm)

29"

(2.5 cm)

(73.6 cm)

(2.5 cm)

1"

1"

 

 

(2.5 cm)

(73.6 cm)

(2.5 cm)

 

 

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0 inches (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

NOTE

ENGL SHI

There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of vibration from one to the other. Too much vibration could cause the appliances to touch each other, causing paint damage and more noise.

14 INSTALLATION INSTRUCTIONS

Installation location requirements (Cont.)

wWarning

Read all installation instructions completely before installing and operating your dryer! It is important that you review this entire manual before installing and using your dryer. Detailed instructions concerning electrical connections, gas connections, and exhaust requirements are provided on the following pages.

A location that allows for proper exhaust installation. A gas dryer must be exhausted to the outdoors. See Venting

Requirements(P.20).

A grounded electrical outlet located within 2 ft. (61 cm) of either side of the dryer. See Electrical Requirements(P.24).

A sturdy floor to support the total dryer weight of 200 lbs (90.7 kg).The combined weight of a companion appliance should also be considered.

No other fuel-burning appliance can be installed in the same closet as a dryer.

Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.

Clearances (Space for Using the Dryer.)

If the duct is installed in the wall.

59"

(151.8 cm)

If the duct isn’t installed in the wall.

64"

 

(164.5 cm)

59"

5"

(151.8 cm)

(12.7 cm)

INSTALLATION INSTRUCTIONS 15

Installation with optional pedestal base or stacking kit

Recommended installation spacing for cabinet installation

• For cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required.

*Required spacing

**For side or bottom venting,

2 inches (5.1 cm) spacing is allowed.

Closet ventilation requirements

7"* (17.8 cm)

7"* (17.8 cm)

9"**

(22.9 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5"**

32.1"

1"**

1"

29"

1"

 

(12.7 cm) (81.4 cm) (2.5 cm)

(2.5 cm)(73.6 cm) (2.5 cm)

Closets with doors must have both an upper and lower vent to prevent heat and moisture buildup in the closet. One upper vent opening with a minimum opening of 48 sq. in. (310 cm2) must be installed no lower than 6 feet above the floor. One lower vent opening with a minimum opening of 24 sq. in. (155 cm2) must be installed no more than one foot above the floor. One example shown uses vent grilles in the door.

Recommended installation spacing for recessed or closet installation, with stacked washer and dryer

• The dimensions shown are for the recommended spacing.

*Required spacing

**For side or bottom venting,

2 inches (5.1 cm) spacing is allowed.

81.6 "

(207.2 cm)

 

1"* (2.5 cm)

51/2"**

 

 

 

 

 

 

 

29"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(14 cm)

 

(73.6 cm)

ENGL SHI

16 INSTALLATION INSTRUCTIONS

Leveling the dryer

wWarning

To reduce the risk of injury to persons, adhere to all industry recommended safety procedures including the use of

long sleeved gloves and safety glasses. Failure to follow this warning can cause serious injury or death.

The appliances are heavy.Two or more people are required when installing the dryer. Failure to follow this warning can cause serious injury or death.

To ensure that the dryer provides optimal drying performance, it must be level. To minimize vibration, noise, and unwanted movement, the floor must be a perfectly level, solid surface.

NOTE

Adjust the leveling feet only as far as necessary to level the dryer. Extending the leveling feet more than necessary can cause the dryer to vibrate.

1.Position the dryer in the final location. Place a level across the top of the dryer.

Level

Leveling Feet

All four leveling feet must rest solidly on the floor. Gently push on the top corners of the dryer to make sure that the dryer does not rock from corner to corner.

If you are installing the dryer on the optional pedestal, you must use the leveling feet on the pedestal to level the dryer. The dryer leveling feet should be fully retracted.

2.Use an adjustable wrench to turn the leveling feet.Turn clockwise to raise the dryer or counterclockwise to lower it. Raise or lower the leveling feet until dryer is level from side to side and front to back.

Make sure that all 4 leveling feet are in firm contact with the floor.

INSTALLATION INSTRUCTIONS

To remove the door

wWarning

To avoid damage to the dryer or the door, support the door with a stool or box that fits under the door, or have an assistant support the weight of the door.

Always reverse the door BEFORE stacking the dryer on top of the washer.

Avoid dropping the door to avoid damage to the door or the floor.

THE DRYER DOOR IS VERY LARGE AND HEAVY. Failure to follow the instructions below can result in damage to the dryer, property damage or injury to persons.

1. Open the door to reverse.

Open Door

2. Check screws to remove (Left 6, Right 4).

3. Remove four dummy screws by driver.

Hinge

Dummy

Screw

17

4.Remove two screws and disassembly Latch.

Latch Screw

5.Hold on the hinge while remove 2 screws of hinge (to prevent door dropping).

Hinge Screw

6. Remove door from cabinet cover.

Remove

Door

ENGL SHI

18 INSTALLATION INSTRUCTIONS

To install the door

wWarning

To avoid damage to the dryer or the door, support the door with a stool or box that fits under the door, or have an assistant support the weight of the door.

Always reverse the door BEFORE stacking the dryer on top of the washer.

Avoid dropping the door to avoid damage to the door or the floor.

THE DRYER DOOR IS VERY LARGE AND HEAVY. Failure to follow the instructions below can result in damage to the dryer, property damage or injury to persons.

1. Move door to left side and insert a hinge to hinge hole.

Hinge hole

2.Hold on hinge while screw down a hinge (to prevent door dropping).

Hinge Screw

4. Screw down four dummy screws right side.

Hinge

Dummy

Screw

5. Check that the door closes and latches properly.

Swing Door

3. Insert latch to right side and install screws.

Latch

Screw

Changing the dryer vent location

wWarning

Use a heavy metal vent.

Do not use plastic or thin foil duct.

Clean old ducts before installing this dryer.

To reduce the risk of injury to persons adhere to all industry recommended safety procedures including the use of long sleeved gloves and safety glasses.

Failure to follow all of the safety warnings in this manual could result in property damage, injury to person or death.

Your new dryer is shipped to vent to the rear.

It can also be configured to vent to the bottom or side (rightside venting is not available on gas models).

An adapter kit, part number 383EEL9001L, may be purchased from your LG retailer. This kit contains the necessary duct components to change the dryer vent location.

1.Remove the rear exhaust duct retaining screw. Pull out the exhaust duct.

Retaining

Screw

Rear

Exhaust Duct

OPTION 1: Side Venting

2.Press the tabs on the knockout and carefully remove the knockout for the desired vent opening (right-side venting is not available on gas models). Press the adapter duct onto the blower housing and secure to the base of the dryer as shown.

Adapter

Duct

Bracket

Knockout

INSTALLATION INSTRUCTIONS 19

 

 

SHI

3. Preassemble a 4 inches (10.2 cm) elbow to the next 4-inches

ENGL

 

(10.2 cm) duct section, and secure all joints with duct tape. Be

 

sure that the male end of the elbow faces AWAY from the dryer.

 

Insert the elbow/duct assembly through the side opening and

 

press it onto the adapter duct. Secure in place with duct tape.

 

Be sure that the male end of the duct protrudes 1½ inches (3.8

 

cm) to connect the remaining ductwork.

 

Attach cover plate to the back of the dryer with included screw.

 

Cover

Plate

Elbow

11/2"

(3.8 cm)

OPTION 2: Bottom Venting

2.Press the adapter duct onto the blower housing and secure to the base of the dryer as shown.

Adapter

Duct

Bracket

3.Insert the 4 inches (10.2 cm) elbow through the rear opening and press it onto the adapter duct. Be sure that the male end of the elbow faces down through hole in the bottom of the dryer. Secure in place with duct tape.

Attach the cover plate to the back of the dryer with included screw.

Cover

Plate

Elbow

20 INSTALLATION INSTRUCTIONS

Venting requirement

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Do not crush or collapse ductwork. Failure to follow these instructions can result in fire or death.

Do not allow ductwork to rest on or contact sharp objects.

Failure to follow these instructions can result in fire or death.

If connecting to existing ductwork, make sure it is suitable and clean before installing the dryer. Failure to follow these instructions can result in fire or death.

Venting must conform to local building codes. Failure to follow these instructions can result in fire or death.

Gas dryers MUST exhaust to the outdoors.

Failure to follow these instructions can result in fire or death.

Use only 4-inch (10.2 cm) rigid or flexible metal ductwork inside the dryer cabinet and for venting outside. Failure to follow these instructions can result in fire or death.

To reduce the risk of fire, combustion, or accumulation of combustible gases, DO NOT exhaust dryer air into an enclosed and unventilated area, such as an attic, wall, ceiling, crawl space, chimney, gas vent, or concealed space of a building.

Failure to follow these instructions can result in fire or death.

To reduce the risk of fire, DO NOT exhaust the dryer with plastic or thin foil ducting.

Failure to follow these instructions can result in fire or death.

The exhaust duct must be 4 inches (10.2 cm) in diameter with no obstructions.The exhaust duct should be kept as short as possible. Make sure to clean any old ducts before installing your new dryer. Failure to follow these instructions can result in fire or death.

Rigid or semirigid metal ducting is recommended for use between the dryer and the wall. In special installations when it is impossible to make a connection with the above recommendations, a UL-listed flexible metal transition duct may be used between the dryer and wall connection only. The use of this ducting will affect drying time. Failure to follow these instructions can result in fire or death.

DO NOT use sheet metal screws or other fasteners which extend into the duct that could catch lint and reduce the efficiency of the exhaust system. Secure all joints with duct tape. Failure to follow these instructions can result in fire or death.

To maximize operating results, please observe the duct length limitations noted in the chart next page. Failure to follow these instructions can result in fire or death.

Ductwork is not provided with the dryer.You should obtain the necessary ductwork locally.The end cap should have hinged dampers to prevent backdraft when the dryer is not in use. Failure to follow these instructions can result in fire or death.

TheTotal length of flexible metal duct shall not exceed 8 ft. (2.4 m)

In Canada, that only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the manufacturer shall be used. In the United States, that only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the manufacturer and that comply with the

Outline for Clothes DryerTransition Duct, Subject 2158A, shall be used.

INSTALLATION INSTRUCTIONS 21

Venting requirement

Ductwork

 

 

 

Number of 90°

Maximum Length of

Wall Cap Type

4-inch Diameter Rigid

 

Elbows

Metal Duct

 

 

Recommended

0

65 ft. (19.8 m)

 

1

55 ft. (16.8 m)

4"

2

47 ft. (14.3 m)

(10.2 cm)

 

3

36 ft. (11.0 m)

4"

4

28 ft. (8.5 m)

(10.2 cm)

Use Only for Short

0

55 ft. (16.8 m)

Run Installations

1

47 ft. (14.3 m )

 

 

2

41 ft. (12.5 m)

21/2"

3

30 ft. (9.1 m)

(6.35 cm)

 

 

 

4

22 ft. (6.7 m)

NOTE

Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended to use more than four 90° elbows.

Routing and Connecting Ductwork

CorrectVenting

IncorrectVenting

NOTE

Follow the guidelines below to maximize drying performance and reduce lint buildup and condensation in the ductwork.

Ductwork and fittings are NOT included and must be purchased separately.

Use 4-inch (10.2 cm) diameter rigid or semirigid metal ductwork.

The exhaust duct run should be as short as possible.

Use as few elbow joints as possible.

The male end of each section of exhaust duct must point away from the dryer.

Use duct tape on all duct joints.

Insulate ductwork that runs through unheated areas in order to reduce condensation and lint buildup on duct surfaces.

Failure to exhaust the dryer correctly will void the dryer’s warranty.

ENGL SHI

22 INSTALLATION INSTRUCTIONS

Connecting gas dryers

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Gas supply requirements:

As shipped from the factory, this dryer is configured for use with natural gas. It can be converted for use with LP (Liquefied Propane) gas. Gas pressure must not exceed 13 inches of water column.

A qualified service or gas company technician must connect the dryer to the gas service.

Failure to do so can result in fire, explosion, or death.

Isolate the dryer from the gas supply system by closing its individual manual shutoff valve during any pressure testing of the gas supply. Failure to do so can result in fire, explosion, or death.

Supply line requirements:

Your laundry room must have a rigid gas supply line to your dryer. In the United States, an individual manual shutoff valve MUST be installed within at least 6 ft. (1.8 m) of the dryer, in

accordance with the National Fuel Gas Code ANSI Z223.1 or Canadian gas installation code CSA B149.1. A 1⁄ - inch NPT pipe plug must be installed. Failure to do so can result in fire, explosion, or death

If using a rigid pipe, the rigid pipe should be ½ - inch IPS.

If acceptable under local codes and ordinances and when acceptable to your gas supplier, 3⁄ - inch approved tubing may be used where lengths are less than 20 ft. (6.1 m). Larger tubing should be used for lengths in excess of 20 ft. (6.1 m).

Failure to do so can result in fire, explosion, or death.

Electrical Requirements for Gas Models Only

wWarning

Connect the dryer to the type of gas shown on the nameplate.

Failure to do so can result in fire, explosion, or death.

To prevent contamination of the gas valve, purge the gas supply of air and sediment before connecting the gas supply to the dryer. Before tightening the connection between the gas supply and the dryer, purge remaining air until the odor of gas is detected. Failure to do so can result in fire, explosion, or death.

DO NOT use an open flame to inspect for gas leaks. Use a noncorrosive leak-detection fluid. Failure to do so can result in fire, explosion, or death.

Use only a new AGAor CSA-certified gas supply line with flexible stainless steel connectors. Failure to do so can result in fire, explosion, or death.

Securely tighten all gas connections. Failure to do so can result in fire, explosion, or death.

DO NOT attempt any disassembly of the dryer; any disassembly requires the attention and tools of an authorized and qualified service person or company. Failure to do so can result in fire, explosion, or death.

Use a pipe-joint compound that is insoluble in Liquefied Petroleum (LP) gas on all pipe threads. Failure to do so can result in fire, explosion, or death.

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. Failure to follow this warning can result in fire, explosion, or death.

For personal safety, this dryer must be properly grounded.

Failure to follow this warning can result in fire, explosion, or death.

The power cord of this dryer is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance. Failure to follow this warning can result in fire, explosion, or death.

This dryer must be plugged into a 60 Hz, 120VAC, grounded outlet protected by a 15-ampere fuse or circuit breaker. Failure to follow this warning can result in fire, explosion, or death.

Where a standard 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet. Failure to follow this warning can result in fire, explosion, or death.

INSTALLATION INSTRUCTIONS 23

Connecting gas dryers (cont.)

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Installation and service must be performed by a qualified installer, service agency, or the gas supplier. Failure to do so can result in fire, explosion, or death.

Use only a new stainless steel flexible connector and a new AGA-certified connector. Failure to do so can result in fire, explosion, or death.

A gas shutoff valve must be installed within 6 ft. (1.8 m) of the dryer. Failure to do so can result in fire, explosion, or death.

The dryer is configured for Natural Gas when shipped from the factory. Make sure that the dryer is equipped with the correct burner orifice for the type of gas being used (Natural Gas or Liquefied Petroleum). Failure to do so can result in fire, explosion, or death.

If necessary, the correct orifice (for the LP, orifice kit order part number 383EEL3002D) should be installed by a qualified technician and the change should be noted on the dryer. Failure to do so can result in fire, explosion, or death.

All connections must be in accordance with local codes and regulations. Failure to do so can result in fire, explosion, or death.

Gas dryers MUST exhaust to the outdoors. Failure to do so can result in fire, explosion, or death.

Connecting the Gas Supply

1.Make sure that the gas supply to the laundry room is turned

OFF. Confirm that the type of gas available in your laundry room is appropriate for the dryer. The dryer is prepared for Natural Gas with a 3⁄ - inch NPT gas connection.

2.Remove the shipping cap from the gas connection at the back of the dryer. Be careful not to damage the threads of the gas connector when removing the shipping cap.

3.Connect the dryer to your laundry room’s gas supply using a new flexible stainless steel connector with a 3⁄ - inch NPT fitting.

4.Securely tighten all connections between the dryer and your laundry room’s gas supply. Turn on your laundry room’s gas supply and check all pipe connections (both internal and external) for gas leaks with a noncorrosive leak-detection fluid.

Electrical Connection

Plug dryer into a 120VAC, 60

Hz grounded 3-prong outlet.

3/8”NPT Gas

1/8”NPT Pipe

Plug

Connection

Gas Supply

 

AGA/CSA-Certified

Shutoff Valve

Stainless Steel Flexible

 

Connector

 

High-Altitude Installations

The BTU rating of this dryer is AGA-certified for elevations below 10,000 feet.

If your gas dryer is being installed at an elevation above 10,000 feet, it must be derated by a qualified technician or gas supplier.

ENGL SHI

24 INSTALLATION INSTRUCTIONS

Connecting electric dryers

wWarning

To help prevent fire, electric shock, serious injury, or death, the wiring and grounding must conform to the latest edition of the

National Electrical Code, ANSI/NFPA 70 and all applicable local regulations. Please contact a qualified electrician to check your home’s wiring and fuses to ensure that your home has adequate electrical power to operate the dryer.

Electrical Requirements for Electric Models Only

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer. Failure to do so can result in fire, explosion, or death.

The dryer has its own terminal block that must be connected to a separate 240VAC, 60-Hertz, single-phase circuit, fused at 30 amperes (the circuit must be fused on both sides of the line). ELECTRICAL SERVICE FORTHE DRYER SHOULD BE OF THE MAXIMUM RATEVOLTAGE LISTED ONTHE NAMEPLATE. DO NOT CONNECT DRYERTO 110-, 115-, OR 120-VOLT CIRCUIT. Failure to follow these instructions can result in fire, explosion, or death.

If branch circuit to dryer is 15 ft. (4.5 m) or less in length, use UL (Underwriters Laboratories) listed No.-10 AWG wire (copper wire only), or as required by local codes. If over 15 ft. (4.5 m), use UL-listed No.-8 AWG wire (copper wire only), or as required by local codes. Allow sufficient slack in

wiring so dryer can be moved from its normal location when necessary. Failure to do so can result in fire, explosion, or death.

The power cord (pigtail) connection between wall receptacle and dryer terminal block IS NOT supplied with dryer.Type of pigtail and gauge of wire must conform to local codes and with instructions on the following pages. Failure to follow these instructions can result in fire, explosion, or death.

A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996. A 4-wire connection must be used where local codes do not permit grounding through the neutral wire. Failure to do so can result in fire, explosion, or death.

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Do not modify the plug and internal wire provided with the dryer.

The dryer should be connected to 4-hole outlet.

If it does not fit the outlet, a proper outlet will need to be installed by a qualified electrician.

wWarning

To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Any installation in a manufactured or mobile home must comply with the Manufactured Home Construction and Safety StandardsTitle 24 CFR, Part 3280 or Standard CAN/ CSA Z240 MH and local codes and ordinances.

A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996. Failure to do so can result in fire, explosion, or death.

INSTALLATION INSTRUCTIONS 25

Connecting electric dryer(cont.) USA only

wWarning

Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short or overload, fire, explosion, or death.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile homes,

(3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.

Four-Wire connection for electric dryers:

Power cord

A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996.

A UL-listed strain relief is required.

1.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread a UL-listed, 30 A, 240 V, 4-wire, #10 AWG-minimum copper conductor power cord through the strain relief.

Terminal

Block

UL-Listed

Strain Relief

Use a 30 A, 240 V, UL-listed power cord with #10 AWGminimum copper conductor and closed loop or forked terminals with upturned ends.

2.Transfer the dryer’s ground wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads of the power cord to the outer terminal block screws. Attach the white neutral wire to the center terminal block screw. Attach the power cord ground wire to the green ground screw. Tighten alL screws securely. Reinstall the terminal block access cover.

Hot

Neutral

 

(Black)

(White)

Hot

Ground

 

(Red)

 

 

Screw

 

 

Power Cord

Ground Wire

ENGLISH

UL-Listed

4-Wire Power

Cord

26 INSTALLATION INSTRUCTIONS

Connecting electric dryer(cont.) USA only

wWarning

Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short or overload, fire, explosion, or death.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile homes,

(3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.

Four-Wire connection for electric dryers: Direct wire

A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996.

A UL-listed strain relief is required.

1.Remove 5 inches (12.7 cm) of the outer covering from the wire.

Remove 5 inches of insulation from the ground wire. Cut off approximately 11⁄ inches (3.8 cm) from the other three wires and strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three shorter wires into a hook shape.

1" (2.5 cm)

Ground Wire

5" (12.7 cm)

Use UL-listed 4-wire #10 AWG-minimum copper conductor cable.

Allow at least 5 ft. (1.5 m) length to allow for removal and reinstallation of the dryer.

3.Transfer the dryer’s ground wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads of the power cable to the outer terminal block screws. Attach the white neutral wire to the center terminal block screw. Attach the power cable ground wire to the green ground screw. Tighten aLl screws securely. Reinstall the terminal block access cover.

Hot

Neutral

 

(Black)

(White)

Hot

Ground

 

(Red)

 

 

Screw

 

 

Power Cord

Ground Wire

2.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread the power cable prepared in Step 1 through the strain relief.

Terminal

Block

UL-Listed

Strain Relief

UL-Listed

4-Wire Power

Cord

INSTALLATION INSTRUCTIONS 27

Connecting electric dryer(cont.) USA only

wWarning

Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short or overload, fire, explosion, or death.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile homes,

(3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.

Three-Wire connection for electric dryers:

Power cord

A 3-wire connection is NOT permitted on new construction after January 1, 1996.

A UL-listed strain relief is required.

1.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread a UL-listed, 30 A, 240 V, 3-wire, #10 AWG-minimum copper conductor power cord through the strain relief.

Terminal

Block

UL-Listed

Strain Relief

UL-Listed

3-Wire Power

Cord

Use a 30 A, 240 V, UL-listed power cord with #10 AWGminimum copper conductor and closed loop or forked terminals with upturned ends.

2.Attach the two hot leads of the power cord to the outer terminal block screws. Attach the neutral wire to the center terminal block screw. Connect the external ground (if required by local codes) to the green ground screw. Tighten aLl screws securely. Reinstall the terminal block access cover.

 

Hot

Neutral

Hot

Ground

(Black)

(White)

 

 

(Red)

Screw

 

 

 

 

 

External

Ground Wire

ENGLISH

28 INSTALLATION INSTRUCTIONS

Connecting electric dryer(cont.) USA only

wWarning

Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short or overload, fire, explosion, or death.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile homes,

(3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.

Three-Wire connection for electric dryers: Direct wire

A 3-wire connection is NOT permitted on new construction after January 1, 1996.

A UL-listed strain relief is required.

1.Remove 31⁄ inches (8.9 cm) of the outer covering from the wire. Strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three wires into a hook shape.

1" (2.5 cm)

2.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread the power cable prepared in Step 1 through the strain relief.

Terminal

Block

UL-Listed

Strain Relief

UL-Listed

3-Wire Power

Cord

Use UL-listed 3-wire #10 AWG-minimum copper conductor cable.

Allow at least 5 ft. (1.5 m) length to allow for removal and reinstallation of the dryer.

3.Attach the two hot leads of the power cord to the outer terminal block screws. Attach the neutral wire to the center terminal block screw. Connect the external ground (if required by local codes) to the green ground screw. Tighten all screws securely. Reinstall the terminal block access cover.

 

Hot

Neutral

Hot

Ground

(Black)

(White)

 

 

(Red)

Screw

 

 

 

 

 

External

Ground Wire

INSTALLATION INSTRUCTIONS 29

Special requirements for manufactured or mobile homes

Any installation in a manufactured or mobile home must comply with the Manufactured Home Construction and Safety Standards

Title 24 CFR, Part 3280 or Standard CAN/CSA Z240 MH and local codes and ordinances. If you are uncertain whether your proposed installation will comply with these standards, please contact a service and installation professional for assistance.

A gas dryer must be permanently attached to the floor.

The electrical connection for an electric dryer must be a 4-wire connection. More detailed information concerning the electrical connection is provided in the section Connecting Electric Dryers.

To reduce the risk of combustion and fire, the dryer must be vented to the outside.

DO NOT vent the dryer under a manufactured home or mobile home.

Electric dryers may be vented to the outside using the back, left, right, or bottom panel.

Gas dryers may be vented to the outside using the back, left, or bottom panel. Gas dryers may not be vented to the outside using the right side panel because of the burner housing.

The dryer exhaust duct must be affixed securely to the manufactured or mobile home structure, and the exhaust duct must be made of a material that will resist fire and combustion. It is recommended that you use a rigid or flexible metal duct.

DO NOT connect the dryer exhaust duct to any other duct, vent, chimney, or other exhaust duct.

Make sure the dryer has adequate access to outside fresh air to

ensure proper operation. The opening for outside fresh air must be at least 25 in2 (163 cm2).

It is important that the clearance of the duct from any combustible construction be at least 2 inches (5 cm), and when venting the dryer to the outdoors, the dryer can be installed with a clearance of 1 inch (2.5 cm) at the sides and back of the dryer.

Please be aware that venting materials are not supplied with the dryer. You should obtain the venting materials necessary for proper installation.

Final installation check

Once you have completed the installation of the dryer and it is in its final location, confirm proper operation with the following tests and InstallationTest (Exhaust check) on the following page.

Testing dryer heating

GAS MODELS

Close the dryer door, press the ON/OFF button to turn the dryer on, and start the dryer on a heat setting. When the dryer starts, the igniter should ignite the main burner.

NOTE

If all air is not purged from the gas line, the gas igniter may turn off before the main burner ignites. If this happens, the igniter will reattempt gas ignition after approximately two minutes.

Electric models

Close the dryer door, press the ON/OFF switch to turn the dryer on, and start the dryer on a heat setting. The exhaust air should be warm after the dryer has been operating for 3 minutes.

Checking airflow

Effective dryer operation requires proper airflow.

The adequacy of the airflow can be measured by evaluating the static pressure. Static pressure in the exhaust duct can be measured with a manometer, placed on the exhaust duct approximately 2 ft. (60.9 cm) from the dryer.

Static pressure in the exhaust duct should not exceed 0.6 inches (1.5 cm).The dryer should be checked while the dryer is running with no load.

Checking levelness

Once the dryer is in its final location, recheck the dryer to be sure it is level. Make sure it is level front to back and side to side, and that all 4 leveling feet are firmly on the floor.

ENGL SHI

30 INSTALLATION INSTRUCTIONS

Installation test (Exhaust check)

Once you have completed the installation of the dryer, use this test to make sure the condition of the exhaust system is adequate for proper operation of the dryer. This test should be performed to alert you to any serious problems in the exhaust system of your home.

Your dryer features Flow SenseTM, an innovative sensing system that automatically detects blockages and restrictions in dryer ductwork. Keeping ductwork clean of lint buildup and free of restrictions allows clothes to dry faster and reduces energy use.

NOTE

The dryer should be cool before starting this test. If the dryer was warmed up during installation, run the AIR DRY cycle for a few minutes to reduce the interior temperature.

To activate the Installation test:

1.Remove the drying rack and literature, and then close the door.

Do not load anything in the drum for this test, as it may affectthe accuracy of the results.

4.Check the display for results.

During the two minutes test cycle, monitor the Flow SenseTM display on the control panel. If no bars are displayed, when the cycle ends, the exhaust system is adequate. If the exhaust system is severely restricted, the display will show four bars. Other problems may also be shown with error codes. Refer to the next page for error code details and solutions.

 

 

 

 

NO BARS:

FOUR BARS:

OK

RESTRICTED

5.END of Cycle.

At the end of the test cycle, will display. The test cycle will end and the dryer will shut off automatically after a short delay.

2.Press and hold the SIGNAL andTEMP. CONTROL buttons and then press the POWER button.

This button sequence activates the installation test. The code

will display if the activation is successful.

3.Press START/PAUSE button.

The dryer will start the test, which will last about two minutes. The heater will be turned on and the temperatures in the drum will be measured.

Loading...
+ 114 hidden pages