KROHNE PTD500 User Manual

Page 1
GR
Installation and Operating Instructions
PTD 500
©
KROHNE 12/2003 7.02277.21.00
Subject to change without notice.
Variable area flowmeters
Flow controllers
Electromagnetic flowmeters
Ultrasonic flowmeters
Mass flowmeters
Level measuring instruments
Communications technology
Engineering systems & solutions
Switches, counters, displays and recorders
Heat metering
Pressure and temperature
Page 2
Content
Safety information..........................................................................................................................3
Items includes with supply............................................................................................................3
Produkthaftung und Garantie .......................................................................................................3
CE / EMC / Standards/ Approvals .................................................................................................3
1
Installation...........................................................................................................................4
1.1 Mechanical installation..........................................................................................................4
1.2 Process connection...............................................................................................................4
1.3 Electrical connection ............................................................................................................. 4
1.3.1 Connection diagrams ............................................................................................................ 5
1.3.2 Start-up ................................................................................................................................. 5
1.3.3 Operator control ....................................................................................................................5
Technical data ..................................................................................................................... 6
2
2.1 Technical data.......................................................................................................................6
2.2 Dimensions ...........................................................................................................................7
3
Ordering code .....................................................................................................................8
3.1 Ordering code .......................................................................................................................8
3.2 Spare parts ...........................................................................................................................8
3.3 Accessories ..........................................................................................................................8
Product description ............................................................................................................ 9
4
4.1 Applications ..........................................................................................................................9
4.2 Functional principle ............................................................................................................... 9
4.3 Construction.......................................................................................................................... 9
4.4 Features................................................................................................................................ 9
If you need to return a device for testing or repair to KROHNE...............................................11
2 Installation and Operating Instructions PTD 500
Page 3
Safety information
Please read this manual carefully, and also take note of country-specific installation standards (e.g. the VDE regulations in Germany) as well as prevailing safety regulations and accidents prevention rules. For safety and warranty reasons, any internal work on the instruments, apart from that involved in normal installation and electrical connection, must be carried out only by qualified KROHNE personnel.
Items includes with supply
Measuring instrument
Hygienic adapter
Installation and operating instructions
Produkthaftung und Garantie
Responsibility for suitability and intended use of these instruments rests solely with the operator. Improper installation and operation of the instruments may lead to loss warranty.
In addition, the “General conditions of sale” forming the basis of the purchase contract are applicable.
If instruments need to be returned to KROHNE, please note the information given on the last-but­one page of these instructions.
KROHNE regrets that it cannot repair or check your instruments unless accompanied by a fully completed Service and Repair sheet.
CE / EMC / Standards/ Approvals
The product bears the CE marking on account of compliance with and application of the following standards:
EMCG (89/336/EEC)
EN 50081-1, 50081-2 EN 61326 EN 50121-4
Installation and Operating Instructions PTD 500 3
Page 4
1 Installation
1.1 Mechanical installation
Use only the recommended sleeves or adapters. If other systems are used, no guarantee can be given for proper functioning or leak tightness.
Before installing and dismantling the sensor, make sure that the system is non-pressurised!
Do not use Teflon or paper gaskets.
Insert the measuring head with care and straight into the sleeve. Screw the sensor in by hand.
Then tighten down using an open-end wrench applied to the hexagon (jaw size 41) with a torque between 20 and 30 Nm.
On no account may a tightening torque be applied anywhere else other than at the hexagon!
Following assembly, the position marking of the sleeve points to the outgoing cable and the
filter cover for the air vent. When welding in the sleeve, please bear this in mind for suitable positioning.
1.2 Process connection
The hygienic G1“h process sleeves are easy to weld into tanks or pipes. The marking points to the centre of the future position of the cable glands or M12 connector. This form of assembly allows installation in conformity with standards of hygiene (to EHEDG, 3A and FDA). Various hygienic adapter sleeves (see Accessories) are available for fitting to other process connections. The device can be installed in any desired position.
1.3 Electrical connection
Installation of the device in the plant may only be carried out by an electrician. Observe the national and international regulations for the installation of electrical systems and equipment.
For voltage supplies, use a suitable power supply unit (EN50178, SELV, PELV) with a voltage of between 16 V and 30 V.
Disconnect the plant from supply before connecting up the devices.
Do not loosen or detach connections when energised.
To avoid adverse effects due to interference voltages, a shielded cable is recommended if
there is any greater distance between sensor and display.
The sensor operates as a 2-wire device (current sink). Normally, connection of cables L+ (1) and I - (2) will suffice, see connection diagram 1.
4 Installation and Operating Instructions PTD 500
Page 5
1.3.1 Connection diagrams
PTD 500
1: braun / brown 2: weiß / white
1.3.2 Start-up
Check for leak-tightness at the sleeve.
Make sure that the cable glands are tight and, as the case may be, the M12 connectors are
properly tightened down.
Check that the device is functioning properly (current output).
Make sure that the housing lid is screwed down tight.
1.3.3 Operator control
The device itself has no an auto zero function by pressing the button located behind the electrical plug
Installation and Operating Instructions PTD 500 5
Page 6
2 Technical data
2.1 Technical data
Housing materials SS 1.4301,1.4305/ SS 304,PBT(M12), PA (plug) Electrical connection Cable gland or M12 connector 4-pin (plug) Type (class) of protection IP 67, III Insulation resistance > 1 GOhm ( 500 V DC) Shock resistance EN 60068-2-6 Vibration resistance EN 60068-2-6 Ambient temperature –25...+80 °C Voltage supply 10...30 V DC Analogue output 4...20 mA Max. load impedance RL < 50 x Ub - 450 Rise time 1) 25 ms Accuracy in % 2) < ± 0.4 %
- Linearity < ± 0.1 %
- Hysteresis < ± 0.05 %
- Repeatability < ± 0.05 %
- Long-time stability < ± 0.2 % FS / year Temperature coefficients Span < ± 0,1 % / 10 K Process temperature –30...+125 °C (not compensated), -10..+80°C (comp.) CIP/ SIP +140 °C, (max. 60 minutes) Wetted materials 1.4435/1.4404
1) damping dAA = 0
2) all details based on a turn-down ratio of 1:1 in % of span
6 Installation and Operating Instructions PTD 500
Page 7
2.2 Dimensions
PTD 500
Dimensions in mm
Installation and Operating Instructions PTD 500 7
Page 8
3 Ordering code
3.1 Ordering code
Identification Key Pressure Sensor VGP 4 0 1
0
PTD 500
Pressure range
0 - 160 mbar
1
0 - 250 mbar
2
0 - 400 mbar
3
0 - 600 mbar
4
0 - 1 bar
5
0 - 1,6 bar
6
0 - 4 bar
7
0 - 6 bar
8
0 - 10 bar
A
0 - 16 bar
B
0 - 20 bar
C
Customer specific measuring range
K
Electrical Connection
Screwed cable gland M 16
1
Plug M 12
2
Accessories
Without
0
Certificates
Without
L M N P R S
T U V W X
0 - 2 psig 0 - 4 psig 0 - 6 psig 0 - 9 psig 0 - 15 psig 0 - 20 psig 0 - 60 psig 0 - 90 psig 0 - 150 psig 0 - 200 psig 0 - 300 psig
VGP4 0 1 Order designation
3.2 Spare parts
Should a replaceable part of the pressure sensor be lost or damaged, a replacement ca be ordered on the basis of the appropriate parts number.
Designation Type
Housing lid KMD.008.055.100 Cable gland M16 KVV.M16.010.008 Plug insert M12 KVV.100.004.000 Plug-in part, 4-pin KVK.046.210.018
3.3 Accessories
Designation Typ
Varivent flange version N HVF 550 Sanitary pipe assembly kit DN 50 HMM 550 Tri-Clamp flange DN 32, DN 40, 2" HTC 550 Programming and display device PPM 100
Other process connections available on request.
8 Installation and Operating Instructions PTD 500
Page 9
4 Product description
4.1 Applications
The pressure sensor with flush-front stainless steel diaphragm and piezoresistive measuring principle is suitable for pressure and hydrostatic pressure level measurement demanding high standards in terms of hygiene and accuracy. The sensor is distinguished by a extremely good long-time stability, a very small temperature drift and good overload withstand capability.
4.2 Functional principle
The piezo-resistive silicon sensor is anodic bonded on a very stable glass base, which is attached to a stainless steel construction. This assembly guaranties an excellent thermal isolation. The sensor is located from the process by a stainless steel diaphragm (1.4404/316 L) and a filling liquid.
4.3 Construction
The weld able process sleeve, made of stainless steel, ensures installation in keeping with hygiene requirements. The electronic evaluator is fully integrated into the stainless steel housing. The connection head allows convenient and reliable electrical connection. The device supplies a 4...20-mA signal in 2-wire connection technology (current sink).
4.4 Features
Compact design, of stainless steel
Integrated electronic unit with 4...20-mA current sink
flush-front stainless steel diaphragm and piezoresistive measuring principle
High overload withstand capability
Optimum corrosion and abrasion resistance
With CIP and SIP capability
Defined position of the cable gland
Hygienic adapter sleeves for other process connections
Installation and Operating Instructions PTD 500 9
Page 10
Notes
10 Installation and Operating Instructions PTD 500
Page 11
If you need to return a device for testing or repair to KROHNE
Your instrument has been carefully manufactured and tested. If installed and operated in accordance with these operating instructions, your instrument will rarely present any problems. Should you nevertheless need to return an instrument for checkout or repair, please pay strict attention to the following points:
Due to statutory regulations concerning protection of the environment and safeguarding the health and safety of our personnel, KROHNE may only handle, test and repair returned instruments that have been in contact with liquids if it is possible to do so without risk to personnel and environment.
This means that KROHNE can only service your instrument if it is accompanied by a certificate in line with the following model confirming that the instrument is safe to handle.
S P E C I M E N certificate
Company: ……………………………………….. Address: ……………………………………………
Department: …………………………………….. Name: ………………………………………………
Tel. No.: ………………………………………….
The enclosed instrument
Type: …………………………………………………………………………………………………………
KROHNE Order No. or Series No ………………………………………………………………………...
has been operated with the following liquid: ……………………………………………………………..
Because this liquid is water-endangering * / toxic * / caustic * / flammable * we have – checked that all cavities in the instrument are free from such substances * – flushed out and neutralized all cavities in the flowmeter *
(* delete if not applicable)
We confirm that there is no risk to man or environment through any residual liquid contained in the instrument.
Date: ………………………….. Signature: ……………………………………………………………..
Company stamp:
Installation and Operating Instructions PTD 500 11
If the instrument has been operated with toxic, caustic, flammable or water-endangering liquids, you are kindly requested
to check and ensure, if necessary by rinsing or neutralizing, that all cavities in the instrument are free from such dangerous substances. (Directions on how you can find out whether the primary head has to be opened and then flushed out or neutralized are obtainable from KROHNE on request.)
to enclose a certificate with the instrument confirming that the instrument is safe to handle and stating the liquid used.
KROHNE regret that they cannot service your instrument unless it is accompanied by such a certificate.
Loading...