![](/html/23/2320/23206ddf2353c695db6f608f2f18d6522ab17e00cf42f3cd659576e3f41e9953/bg1.png)
OPTIWAVE 1400 C –
Focus is everything
OPTIWAVE 1400 C –
The FMCW radar with a sharp focus on liquids
Featuring a robust IP68 design with wetted parts made of stainless steel
and polypropylene (PP), this level transmitter perfectly fits the requirements of the water and wastewater industry.
Just like all previous non-contact radar transmitters from KROHNE, the
new OPTIWAVE 1400 C uses FMCW radar technology. Its proven PP Drop
antenna, with the smallest beam angle on the market, guarantees a sharp
focus on liquids, unsusceptible to condensation, turbulent surfaces or
foam.
Competitive in price, easy to install and operate, the OPTIWAVE 1400 C
ensures continuous level measurement without maintenance over a long
period of time.
3-year
warranty
OPTIWAVE 1400 C
![](/html/23/2320/23206ddf2353c695db6f608f2f18d6522ab17e00cf42f3cd659576e3f41e9953/bg2.png)
Precision that lasts
If you are looking for a consistently precise, versatile, and reliable
liquid level measurement solution that you can install and never
worry about again, the OPTIWAVE 1400 C is your level transmitter.
Øa
b
1
2
Highlights
• FMCW technology for greater resolution, just like the new
80 GHz generation
• Proven polypropylene (PP) Drop antenna, insensitive
to condensation or deposits
• Narrow beam angle for a sharp focus on the medium
• Robust stainless steel design (IP68 NEMA 4X/6)
• Maintenance-free design
• Simple, safe and secure installation and operation
Applications
Ideal for liquids in the water and wastewater industry, or other fields
with liquid storage applications:
• Extraction, transport, storage and distribution of water from
springs, rivers, lakes or the sea
• Rainwater basins
• Open-channel flow measurement and floodwater alarms
• Water, wastewater, sludge or other liquids in storage applications
• Wastewater pumping stations
• Liquid level of plastic tanks (e.g. IBC)
Measuring range 0…20 m/0…66 ft
Frequency range K-band/24 GHz (LPR)
Dielectric constant Ɛ
Accuracy ±2 mm/±0.8
Process temperature –40…+80°C/–40…+176°F
Process pressure
Top housing connection Thread: G 1
Process connection (antenna) Thread: G 3
Ingress protection IP68/NEMA 4X/6
Antenna G 3 Polypropylene (PP) Drop DN100/ 4
Beam angle 8°
Output 4…20 mA HART
Supply voltage 12…30 V DC
Wetted parts Housing: stainless steel
r
≥2
″
–1…3 barg/–14.5…43.5 psig
Flange: low-pressure flange disc (316L)
drilled with holes according to DN100…200
PN 2.5…40/4…8
Antenna: polypropylene (PP)
Connection cable: polyurethane (PUR)
Gasket: EPDM
″
150 lb
®
7
″
c
e
d
Electrical
f
Øg
connection
1: Brown (+)
and blue (–)
2: Shielding
Dimensions
Drop antenna with threaded connections:
Antenna
DN100/4″
Dimensions (mm/inches)
Øa b c d e f Øg
101.6
G 1
20
220.7
282.7
4.00
G 1
0.79
8.69
11.13
83.5
3.29
G 3
G 3
Measuring principle
The radar principle used is called FMCW
(frequency modulated continuous wave).
An FMCW radar continuously emits a linear,
frequency-modulated signal with a constant amplitude (sweep). The distance to the
product is measured indirectly by using the
frequency difference between the emitted
and the received waves.
Commissioning
TM
Use PACTware
and the respective DTM to
commission the device on-site.
Documentation and more:
krohne.com/optiwave
© KROHNE - 07/2019 - 4007695501 Flyer OPTIWAVE1400-R01-en
Subject to change without notice.
Contact
KROHNE Messtechnik GmbH
Ludwig-Krohne-Str. 5
47058 Duisburg
Germany
Tel.: +49 203 301 0
Fax: +49 203 301 103 89
info@krohne.com
Please check www.krohne.com
for your local service contact