KROHNE OPTIFLEX 1100 C Specifications

Technical Datasheet
Technical Datasheet
OPTIFLEX 1100 C
OPTIFLEX 1100 C
OPTIFLEX 1100 COPTIFLEX 1100 C
Technical DatasheetTechnical Datasheet
Guided Radar (TDR) Level Meter
Continuous measurement of liquids and solids
Cost-effective 2-wire loop-powered TDR level meter
Intuitive 5-step quick setup procedure
CONTENTS
OPTIFLEX 1100 C
1 Product features 3
1.1 The cost-effective TDR solution ....................................................................................... 3
1.2 Applications ...................................................................................................................... 5
1.3 Application table for probe selection ............................................................................... 6
1.4 Measuring principle.......................................................................................................... 7
2 Technical data 8
2.1 Technical data................................................................................................................... 8
2.2 Minimum power supply voltage ..................................................................................... 10
2.3 Guidelines for maximum operating pressure................................................................ 11
2.4 Measurement limits ....................................................................................................... 12
2.5 Dimensions and weights ................................................................................................ 13
3 Installation 15
3.1 Ø2 mm / 0.08¨ single cable probe (liquid applications)................................................. 15
3.1.1 Intended use.......................................................................................................................... 15
3.1.2 Mounting position.................................................................................................................. 15
3.2 Coaxial probe (low-viscosity liquid applications)........................................................... 15
3.2.1 Intended use.......................................................................................................................... 15
3.2.2 Mounting position.................................................................................................................. 16
3.3 Ø4 mm / 0.15¨ single cable probe (solid applications) .................................................. 16
3.3.1 Intended use.......................................................................................................................... 16
3.3.2 Mounting position.................................................................................................................. 16
4 Electrical connections 18
4.1 Electrical installation: 2-wire, loop-powered ................................................................ 18
5 Order information 19
5.1 Order code ...................................................................................................................... 19
6 Notes 21
2
www.krohne.com 01/2012 - 4001685801 - TD OPTIFLEX 1100 R01 en
OPTIFLEX 1100 C
1.1 The cost-effective TDR solution
OPTIFLEX 1100 C is a 2-wire TDR level meter for measuring distance, level, volume and mass of liquids and solids. Its simple, compact design allows service technicians to quickly assemble the probe and attach it to a threaded connection. It is an affordable solution for applications that do not require a high level of accuracy and is also an excellent alternative to traditional level controls such as RF Capacitance, conductive and DP transmitters.
PRODUCT FEATURES 1
1 Aluminium housing with optional LCD display screen 2 Converter is rotatable and removable under process conditions 3 Threaded connection (NPT or G) 4 Choice of cable or coaxial probe 5 2-wire loop-powered level meter
Optional integrated display
The display can be ordered with the device or as an accessory. It shows measurement data on a 128 × 64 pixel screen. The configuration menu permits the device to be set up in a small number of intuitive steps.
www.krohne.com01/2012 - 4001685801 - TD OPTIFLEX 1100 R01 en
3
1 PRODUCT FEATURES
Highlights
2-wire loop-powered level meter for liquids and solids
For general-purpose use (non-hazardous areas)
Measuring range up to 20 m / 65.6 ft (liquids) and 10 m / 32.8 ft (solids)
Easy menu navigation without opening the housing
Probes and process connections are made of stainless steel
For process temperatures up to 100°C / 210°F and pressures up to 16 barg / 232 psig
Display in 9 languages: including Chinese, Japanese and Russian
Industries
O.E.M. equipment
O.E.M. equipment
O.E.M. equipmentO.E.M. equipment e.g. as part of an automatic oil lubrication feed system
Machine & skid assembly
Machine & skid assembly
Machine & skid assemblyMachine & skid assembly The control of water and cleaning agents in industrial washing machines, filling machines for ink and beverages
Tank & silo building
Tank & silo building
Tank & silo buildingTank & silo building Tanks for water, oil, underground tanks, rental tanks for glycol etc.
Water & wastewater
Water & wastewater
Water & wastewaterWater & wastewater Level control in water basins, ports, locks
Pulp & paper
Pulp & paper
Pulp & paperPulp & paper All kinds of storage tanks and recyclying tanks
Agriculture
Agriculture
AgricultureAgriculture Water control for greenhouses, livestock feed management, blood recovery in abbatoirs
Chemical
Chemical
ChemicalChemical Storage of plastic pellets
Automotive
Automotive
AutomotiveAutomotive Paint booths, lubricant oils
Food & beverage
Food & beverage
Food & beverageFood & beverage Various storage and recycling tanks for wine, beer, fruit juice, ...
OPTIFLEX 1100 C
Applications
Level measurement in buffer tanks, collectors and simple process applications
Silo level monitoring in quarrying and agriculture
Volume measurement for storage tanks (with a 30-point strapping table)
4
www.krohne.com 01/2012 - 4001685801 - TD OPTIFLEX 1100 R01 en
OPTIFLEX 1100 C
1.2 Applications
1. Level measurement of liquids
2. Level measurement of solids
PRODUCT FEATURES 1
The level meter can measure the level of a wide range of liquid products on a large variety of installations within the stated pressure and temperature range. It does not require any calibration: it is only necessary to adapt the probe length and do a short configuration procedure.
3. Volume measurement
The level meter has a Ø4 mm / 0.15¨ single cable
probe for measuring powders and granulates in silos up to 10 m / 32.8 ft high. It does not require any calibration: it is only necessary to adapt the probe length and do a short configuration procedure.
A strapping table function is available in the configuration menu for volume measurement. Up to 30 volume values can be related to level values. For example:
Level 1= 2 m / Volume 1= e.g. 0.7 m³ Level 2= 10 m / Volume 2= e.g. 5 m³ Level 3= 20 m / Volume 3= e.g. 17 m³
This data permits the device to calculate volumes between strapping table entries.
www.krohne.com01/2012 - 4001685801 - TD OPTIFLEX 1100 R01 en
5
1 PRODUCT FEATURES
1.3 Application table for probe selection
OPTIFLEX 1100 C
Maximum probe length, L
4m/ 13.1ft
10 m / 32.8 ft
20 m / 65.6 ft
Liquids
Liquid applications, 10000 mPa.s (εr≥2.1)
Liquid applications, 500 mPa.s (εr≥1.6)
Storage tanks
Installation in a bypass chamber
Installation in a stilling well
Solids
Powders (εr≥2.1) Granules, <Ø5 mm / 0.2¨ (ε
2.1)
r
Segmented
coaxial
Ø14 mm / 0.55¨
Single
cable
Ø2 mm / 0.08¨
J standard J optional U on request
Single
cable
Ø4 mm / 0.15¨
6
www.krohne.com 01/2012 - 4001685801 - TD OPTIFLEX 1100 R01 en
OPTIFLEX 1100 C
1.4 Measuring principle
This Guided Radar (TDR) level meter has been developed from a proven technology called Time Domain Reflectometry (TDR).
The device transmits low-intensity electromagnetic pulses of approximately one nanosecond width along a rigid or flexible conductor. These pulses move at the speed of light. When the pulses reach the surface of the product to be measured, the pulses are reflected back to the signal converter.
The device measures the time from when the pulse is transmitted to when it is received: half of this time is equivalent to the distance from the reference point of the device to the surface of the product. The time value is converted into an output current of 4...20 mA.
Dust, foam, vapour, agitated surfaces, boiling surfaces, changes in pressure, changes in temperature, changes in dielectric constant and changes in density do not have an effect on device performance.
TDR measurement of level
PRODUCT FEATURES 1
Figure 1-1: TDR measurement of level
1 Transmitted pulses 2 Reflected pulse 3 Pulse amplitude 4 Time of flight 5 Air, ε
6 Liquid, ε
=1
r
1.6. Solid, εr≥ 2.1.
r
www.krohne.com01/2012 - 4001685801 - TD OPTIFLEX 1100 R01 en
7
2 TECHNICAL DATA
OPTIFLEX 1100 C
2.1 Technical data
The following data is provided for general applications. If you require data that is more relevant to your specific application, please contact us or your local representative.
Complete product documentation can be downloaded free of charge from the website (Download Center).
Converter
Measuring system
Application Level and volume measurement of liquids, pastes, powders and granulates
Measuring principle TDR (time domain reflectrometry)
Construction Measuring probe attached directly to a signal converter
Operating conditions
Ambient temperature -40…+80°C/ -40…+176°F
Storage temperature -50…+85°C/ -60…+185°F
Protection category IP 66/67
Integrated LCD display: -20...+60°C / -5...+140°F; if the ambient temperature is not in these limits, the display switches off
Materials
Housing Polyester-coated aluminium Cable entry M20 × 1.5 (plastic cable gland included) or ½ NPT (without cable gland)
Electrical connections
Power supply (terminals) 1430 VDC
Current output load RL [Ω] ≤ ((U
on page 10.
Cable entry capacity (terminal) 0.51.5 mm²
-14 V)/22 mA). For more data, refer to
ext
Minimum power supply voltage
Input and output
Measured variable Time between the emitted and received signal Output signal 420 mA or 3.820.5 mA Resolution ±1 µA
Error signal options High: 22 mA; Low: 3.6 mA
Hold (frozen value)
Display and user interface
User interface options LCD display (128 × 64 pixels in 8-step greyscale with 4-button keypad)
Languages 9 languages are available: English, German, French, Italian, Spanish, Portuguese,
Japanese, Chinese (Mandarin) and Russian
8
www.krohne.com 01/2012 - 4001685801 - TD OPTIFLEX 1100 R01 en
Loading...