Konica Minolta FORCE 50, IP-301 Manual

0 (0)

IP-301

Print Controller

User's Guide

Konica IP-301

© 1997 by Konica Business Machines U.S.A., Inc.

Acknowledgements

All brands and product names are trademarks or registered trademarks of their respective companies.

PostScript ®

A registered trademark of Adobe Systems, Inc.

Agfa Intellifont® Scalable Typef aces

A registered trademark from Agfa Corporation

TrueType ™

A trademark of Apple Computer, Inc.

Centronics®

A registered trademark of Centronics Data Computer Corporation

HP ®, PCL ®, HP-GL ®

A registered trademark of Hewlett-Packard Company

Microsoft ®

A registered trademark of Microsoft Corporation

Windows ™

A trademark of Microsoft Corporation

PowerPage ® & Power Smoothing ®

A trademark of Pipeline Associates, Inc.

This product contains the PowerPage ® interpreter from Pipeline Associates, Inc.

User's Guide Part Number

OP-01-IP301

Correspondence

Please address all correspondence regarding this manual to the following address:

Konica Business Machines U.S.A., Inc.

Digital Systems Solutions Group & New Product Development

500 Day Hill Road

Windsor, CT 06095

Web Site Address on the Internet

To obtain additional product information, visit our Web site at: http://www.kbm.com

Disclaimer Notice

Konica Business Machines U.S.A., Inc. has made every effort to ensure that information in this manual is complete and accurate. However, constant efforts are also being made to improve and update the product. Therefore, Konica Business Machines U.S.A., Inc. shall not be liable for errors in this manual or for any consequential damages resulting from the use of this manual. Information contained herein is subject to change without notice.

___________________________________________________________________________________

Konica IP-301

Welcome to the IP-301 Print Controller User's Guide.

The User's Guide focuses on specifications and functions of the IP-301 print controller, and also provides useful information on printer drivers, driver screens, fonts, symbol sets, and printer commands, etc. This manual is designed to be used as a reference at the network supervisor's workstation.

The print controller interfaces with the main body of your Konica printer, which comes with a separate manual that describes the functions, operations, maintenance, and supplies, etc., of the printer main body. For the convenience of all users, the printer manual should remain with the printer.

The network interface card used on your network printing system is purchased separately, and comes with a manual that is conveniently formatted to fit into this binder, so that it may also be used as a reference at the supervisor's workstation.

Konica is committed to serving you in the best way possible. We welcome your comments on this manual. Please use our correspondence address displayed on the inside front cover. Should you need assistance on technical matters not covered in this manual, please phone the Konica Digital Support lab at 1(800)825-5664.

Konica - The Real Power of Digital Imaging

____________________________________________________________________

Konica IP-301

FCC Regulations

The Konica IP-301generates, uses, and can radiate radio frequency energy. If the equipment is not installed and used in accordance with the instruction manual, interference with radio communications may result. This equipment has been tested and found to comply with the limits for a Class A computing device, pursuant to Subpart J, Part 15, of FCC rules, which are designed to provide reasonable protection against interference from such equipment when it is operating in a commercial environment.

Users operating this equipment in a residential area are likely to cause interference, in which case they may be required to correct the interference at their own expense.

Canadian Department of Communications Regulations

Le présent appareil n’émet pas de bruits radioélectriques dépassant les limites applicables aux de Class A prescrites dans le règlement sur la brouillage radioélectrique édicté par Le Ministère des Communications du Canada.

This equipment does not exceed the Class A limits for radio noise emissions as set out in the radio interference regulations of the Canadian Department of Communications.

UL 5C13

C/UL 5C13

CE EN60950

EN55022

EN50082-1

_______________________________________________________________________

KONICA BUSINESS MACHINES EUROPE GmbH

Lilienthalstraße 1•D-21337 Lüneburg (Germany)•Tel. (0 41 31) 8 86-0•Fax (0 41 31) 8 86-2 99

DECLARATION OF CONFORMITY

Document No./Month.Year:

KBE-CE-97-002

1 /March.1996

We Konica Business Machines Europe GmbH (supplier's name)

Lilienthalstrasse 1 D-21337 Lueneburg (Germany) (address)

declare under our sole responsibility that the product

Printer Controller :

IP-301

 

Video Interface Kit:

VI KIT 7050/7050P

Memory Unit

:

MU-101 (16MB), MU-102 (32MB)

IP-301 PostScript Option

 

 

Network Option

:

KN-201; KN-202

(name, type or model, lot, batch or serial number, possibly sources and number items)

to which this declaration relates is in conformity with the following standard(s) or other normative document(s)

EN60950/08.92

EN60950A1/01.93

EN60950A2/08.93

EN55022 (class B)/1994

EN50082-1/1992:

EN61000-4-2(IEC801-2/IEC1000-4-2)/1995

IEC1000-4-3(ENV50140/EN61000-4)/1995

EN61000-4-4(IEC1000-4-4/IEC801-4)/1995

(title and/or number date of issue of the standard(s) or other normative document(s) (is applicable)

following the provision of Directive

73/23/EEC

 

 

 

 

 

89/336/EEC

 

Council Directive 73/23/EEC on Low Voltage Directive

 

Council Directive 89/336/EEC on Electromagnetic Directive

 

Lueneburg

T. Kabasawa

 

1.3.96

 

President

.

(Place and date of issue)

(name and signature of equivalent

 

 

 

 

 

marking of authorized person)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Registergericht: Lüneburg HRB 811 • Geschäftsführer: Fumio Iwai, Tadashi Kabasawa, Atsushi Kodama, Jürgen Dyrssen • Sitz: Lüneburg

Contents

Section 1: The Print Controller

Basic Functions ........................................................................................

1-2

Specifications ...........................................................................................

1-3

Settings .....................................................................................................

1-4

Layout ......................................................................................................

1-5

I/O Interfaces ............................................................................................

1-6

Memory Configuration .......................................................................

1-15

Section 2: Printer Drivers

 

Installing Printer Drivers ....................................................................

2-2

Checking the Version of A Printer Driver ............................................

2-4

Printer Driver Screens .........................................................................

2-5

Printing Modes ...................................................................................

2-29

Font Information ................................................................................

2-31

Section 3: Symbol Sets

 

Symbol Sets .............................................................................................

3-2

Roman-8 Character Conversion Tables ...............................................

3-20

Section 4: Printer Commands

 

PCL 5 Printer Commands ........................................................................

4-2

Glossary

Index

Section 1: The Print Controller

The Print Controller

Basic Functions

The IP-301 print controller interfaces with your Konica printer main body, enabling you to print directly from your PC or network. The IP-301 supports PCL 5e and PostScript Level 1 & 2 compliant files.

The IP-301 automatically uses the correct language for each print job, provided the print job follows certain industry standard conventions for detecting the beginning and end of each job. The preprocessor checks the beginning of each job to determine the language in which the job was created. When a specific language code is detected, the preprocessor switches to that language, and then processes the job. If the preprocessor cannot determine which language to use, the default language will be used for the job.

The system determines when the end of job is reached by the end-of-file command of each language or by a 30-second time-out. For language switching to function correctly, the system must be able to detect when the end of job is reached.

The PCL 5e interpreter provided in the IP-301 is the PowerPCL from Pipeline Associates, Inc. It is an HP PCL 5e clone that supports multiple resolutions and PJL commands.

The optional PostScript interpreter for the IP-301 is PowerPage2 from Pipeline Associates, Inc. This is a Level 2 PostScript interpreter that also has Level 1 compatibility. The PostScript programming language is specifically tailored to produce images in a device independent manner. PostScript language programs are reproducible on virtually any device without significant differences, except for differences created in the devices themselves.

The IP-301 supports many of the PJL commands as defined by HP. Many special functions are controlled in PCL mode via the PJL commands. Commands to provide bidirectional (BiDi) functionality are also supported.

The Print Controller 1-2

The Print Controller

Specifications

Architecture

IBM Compatible PC System

Processor

133 MHz Intel Pentium

Memory

16 MB standard/128 MB max.

Hard Drive

IDE compatible

Floppy Drive

3.5" Floppy Disk

Input/Output Interfaces

 

Serial

RS-232C Serial Standard

Connector

DB9 male

Baud Rates

4,800~19,200

Parallel

1284 compatible bidirectional

Network Connectivity

Compatible

 

Optional KN-101 or KN-201

 

Ethernet Network Interface (10Base2/10Base-T)

 

(See the User's Guide

 

for the Network Administrator)

PDL Support

 

Standard

PCL 5e

Optional

PostScript

Font Support

 

PCL

13 PCL Fonts

PostScript

35 PostScript Fonts (optional)

Driver Software

 

 

Windows 3.1, 3.11, Windows95,

 

WindowsNT Workstation & Server ver. 3.x, 4.x,

 

Macintosh, and UNIX

Print Controller Features

 

 

Multiple Page Buffering

 

Document Printing

 

Automatic Emulation Switching

 

Automatic Port Switching

 

Konica Compression Transfer Technology

The Print Controller 1-3

The Print Controller

Settings

Default Settings

Default Paper Size

Letter

Default Resolution

400 dpi

Default Emulation

PCL 5e

Default Printer Quality

Text Mode

Serial Port Parameters

9600,N,8,1,Hardware

Other Settings

 

Duplex

Off

Sheet Insertion

Off

Paper Thickness

Normal

Print Density

Engine Default

Finisher Mode

Job Offset

The Print Controller 1-4

The Print Controller

 

Layout

 

 

 

IP-301

IP-301

Front View

Rear View

 

 

Power

 

 

Cord

 

Power

 

Disk Drive

On/OFF

 

 

 

 

 

Serial

 

 

Port

Reset

 

Parallel Port to PC

 

 

Button

 

 

 

 

CN1/CN2

 

 

Monitor

 

 

Port

IMPORTANT:

 

 

1.Before connecting cables to the IP-301, be sure to turn OFF the power.

2.When the Printer connection is not used, be sure the port is covered by a plastic cap. Plastic caps are provided at delivery to cover the Serial Port, Parallel Port, and the lower

monitor port, which are shown in the above Rear View illustration.

The Print Controller 1-5

The Print Controller

I/O Interfaces

Server

Mac

PC

PC or Print

PC or Print

Server

Server

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ethernet

 

 

 

 

 

 

 

-------

 

--------

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

V

V

Network

>

Parallel

Serial

Interface Card

Port

Port

 

Input Buffer

PCL 5e

 

PostScript

Interpreter

 

Interpreter

 

IP-301

 

 

Memory

 

 

V

 

 

Controller

to Printer

 

Interface

 

 

The Print Controller 1-6

The Print Controller

Memory Configuration

The basic configuration of the IP-301 includes 16 MB of RAM, which allows 1-bit mode printing at 400 dpi on all paper sizes. The IP-301 print controller may be upgraded to 128 MB in 32 MB increments to allow 8-bit Grayscale printing on Tabloid (11"x17") paper, or double buffering on smaller paper sizes; or to allow you to process complex jobs.

You may select various image quality modes from your print driver screen to produce various levels of grayscale. The following Table shows the available image quality modes and the grayscale levels they produce.

Print Mode

Print Engine

Print Controller

Grayscale

 

 

 

 

Text

1-Bit Mode

1-Bit Mode

2 Levels

Medium

2-Bit Mode

8-Bit Mode

4 Levels

High

4-Bit Mode

8-Bit Mode

16 Levels

Very High

8-Bit Mode

8-Bit Mode

256 Levels

 

 

 

 

Memory Upgrade Modules

To obtain optimal printer performance, Konica recommends that SIMM modules be installed by a Konica certified technician. For details, contact your Konica service representative; or the Konica Digital Lab, at 1.800.825.5664.

The Print Controller 1-7

Section 2: Printer Drivers

Printer Drivers

Installing Printer Drivers

Windows 3.x

The Printer Drivers that come with the IP-301 Print Controller are actually software programs that enable you to control all the printing settings for the selected printer.

Before you can print from your application (e.g., spreadsheet or word processor), the appropriate printer driver must be installed on your computer system.

Installing Printer Drivers is a simple procedure that includes the following:

Installing a printer driver

Assigning a port to the printer

Specifying settings for your printer (optional)

Setting the default printer

Installing the Windows 3.x Printer Driver

1.Double-click the Main icon in Program Manager.

2.Choose the Control Panel icon.

3.In the control Panel window, choose the Printers icon.

4.Choose the Add button.

5.In the List Of Printers box, select Install Unlisted or Updated Printer. Depending upon the printer driver version, you may need to use the Browse button to find and select the driver. Then, click on OK until you get to the Add Unlisted or Updated Printer box.

NOTE: To install a driver that is listed, but not installed, simply highlight it in the List of Printers box.

6.Choose the Install button.

7.Insert the disk containing the printer driver into your floppy drive, The default for the Konica drivers is drive A. If you are using a different drive, specify it. When the appropriate drive is selected, click on OK.

8.In the Add Unlisted or Updated Printer box, select the appropriate driver and click on OK.

9.The printer name will appear in the list of installed printers.

2-2 Printer Drivers

Printer Drivers

Installing Printer Drivers

Windows 3.x

Assigning a Port

By default, LPT1 will be assigned to the newly installed printer.

1.To assign a different port, click on the Connect button.

2.In the Ports list, select the port you want to assign to the printer.

NOTE: When installing to a network, up to three LPT printers can be assigned (LPT1, LPT2, LPT3) without having to add more through the WIN.INI file. Should it be necessary to add more than three printers, click on the Help button in the Connect box for instructions.

Tip: If you print to LPT1 in Windows 3.x and LPT1 is redirected to another port, the printer will not print. To correct this, select LPT1.DOS in the Connect dialog box.

Specifying Printer Settings

This is an optional step for making changes to the default printer settings, such as paper size or orientation. These settings can be temporarily overridden from within your application.

1.Click on the Setup button in the Printers dialog box.

2.When the Setup box is displayed, make the desired selections.

Setting the Default Printer

When you install a printer, it will automatically be highlighted in the Printers dialog box.

1.Highlight the printer you want as the default printer.

2.Click on the Set As Default Printer button.

NOTE: Some applications act as a control panel, making their settings become the system default. This is not a function of the driver.

Printer Drivers 2-3

Printer Drivers

Checking the Version of A Printer Driver

Windows 3.x

There may be times when you need to know if you are using the most up-to- date printer driver. Use the following procedure to check the version of a printer driver.

1.Highlight the driver in the Printers dialog box.

2.Click on the Setup button.

3.Click on the About button.

4.The About dialog box will be displayed with the printer version shown.

2-4 Printer Drivers

Printer Drivers

Printer Driver Screens

For convenience, selected printer driver screens are displayed starting on the next page to show the various screens for making printing selections. Samples include PostScript printer driver screens for Windows 3.1, and PCL and PostScript printer driver screens for Windows 95.

The Windows 3.1 screens are similar to those in Windows for Workgroups. Many Windows 95 screens are similar to those in WindowsNT.

When you select Print from your application, a screen displays that is specific for your installed driver. You may use the default settings shown on the screen, or you may select options associated with each printing mode.

For a description of Printing Modes and Fonts that are available, see the pages following sample driver screens.

Making Print Selections from Your Driver Screen

1.From your printer driver screen, click on the desired printing mode.

2.Scroll to options associated with the mode by clicking the up or down arrows.

3.When all desired settings are indicated on the screen, click on OK.

Printer Drivers 2-5

Konica Minolta FORCE 50, IP-301 Manual

Printer Drivers

Printer Driver Screens

PostScript Driver for Windows 3.1

Basic Printer Screen

Advanced Options Screen

2-6 Printer Drivers

Printer Drivers

Printer Driver Screens

PostScript Driver for Windows 3.1

Offset

Staple

2-7 Printer Drivers

Printer Drivers

Printer Driver Screens

PostScript Driver for Windows 3.1

Print Quality

Special Modes

2-8 Printer Drivers

Printer Drivers

Printer Driver Screens

PostScript Driver for Windows 3.1

Special Modes (continued)

Insert Tray

Printer Drivers 2-9

Printer Drivers

Printer Driver Screens

PostScript Driver for Windows 3.1

Paper Type

Output Bin

2-10 Printer Drivers

Printer Drivers

Printer Driver Screens

PostScript Driver for Windows 3.1

Output Order

Printer Drivers 2-11

Printer Drivers

Printer Driver Screens

PCL Driver Screens for Window 95

General Screen

2-12 Printer Drivers

Printer Drivers

Printer Driver Screens

PCL Driver Screens for Windows 95

Details Screen - Selecting Printer Port

Printer Drivers 2-13

Printer Drivers

Printer Driver Screens

PostScript Driver Screens for Windows 95

Device Options - Selecting Print Quality

Printer Drivers 2-23

Printer Drivers

Printer Driver Screens

PCL Driver Screens for Windows 95

Setup Screen - Paper Size

2-14 Printer Drivers

Printer Drivers

Printer Driver Screens

PCL Driver Screens for Windows 95

Advanced Screen - Selecting the FS-103 Finisher

Printer Drivers 2-19

Printer Drivers

Printer Driver Screens

PCL Driver Screens for Windows 95

Advanced Screen - Job Offset Mode

2-20 Printer Drivers

Loading...
+ 70 hidden pages