KEYENCE EM User Manual

96M0202
j

Specifications

Proximity sensors with in-cable amplifiers
EM series
Instruction Manual

Output circuit

NPN type
Brown
Load
Black
Proximity
sensors
main circuit
(control output)
Blue

Hints on correct use

Do not use this product for
Warning
Mounting cylindrical type
Attach the mounting screw to the sensor
Mounting thread type
When mounting thread type sensor head, tightening torque should be less than specified below.
the purpose of protecting the human body.
at minimum of 5mm away from the tip of the sensor. Be sure to keep the tightening torque less than 0.4Nm when mounting.
M3 screw
Model EM-005 EM-010 EM-014
5mm min
Torque
1.5Nm max. 10Nm max. 20Nm max.
DC10.8 to 30V
0V
PNP type
Brown
Black
Proximity
sensors
main circuit
(control output)
Blue
Mutual interference
When installing a number of proximity sensors of the same model either face-to­face or side-by-side, provide the minimum distance given in the table between each sensor.
The values enclosed in brackets are
Note :
when a different frequency type is used.
Face-to-face
Distance
installation
Model
EM-030 EM-038 EM-005 EM-054 EM-080 EM-010 EM-014
Two types with different frequencies available. (A) or (B) is written after each type name.
12(1) 15(1) 12(1.5) 20(1.5) 24(2.5) 20(2.5) 40(4.5)
Installing amplifier unit
A mounting bracket is supplied as a standard accessory. Use it to secure the amplifier unit.
Do not use setscrews to
secure the amplifier unit.
(
)
installation
11 12 13 18 23 25 34
Load
Side-by-side
DC10.8 to 30V
0V
(
(contact installation)
(contact installation)
(contact installation)
(contact installation)
(contact installation)
(contact installation)
(contact installation)
Type
Shape
Model
Detecting distance
Target
Standard target
mm
[iron, t=(1
Hysteresis
Response frequency
Output mode
Temperature drift
Control output
Rating Environmental durability
Supply voltage
Current consumption
Degree of protection
Ambient operating temperature
Relative humidity
Head case material
Weight(nuts and 2 meter-long cable included)
1 PNP output types are different models from NPN output types and specified by letter P at the end of the model numbers.(Ex : EM-030P) 2 Use a power range between 10.8 and 30V if ripple occurs. 3 The figures in ( ) are for PNP output type.
Cylindrical Cylindrical
3
3.8
EM-038
0.8mm±15%
1.0mm±15%
Ferrous metals (See catalog for nonferrous metals)
5×5mm
±10% of detecting distance at 23˚C (73˚F) [-10 to +70˚C (-13 to +158˚F)]
NPN open-collector 200mA max. (40V max.) Residual voltage : 1V max.
PNP open-collector 200mA max. (30V max.) Residual voltage : 1V max. 1
10.8 to 30VDC, Ripple(P-P) : 10%max. 2
-25 to +80˚C (-1 to +176˚F), No freezing
Stainless steel Chromium plates brass
Approx. 38g
)]
EM-030
0.6mm±15%
Approx. 36g
Shielded
Thread
type
M5
EM-005
5.4
EM-054
1.2mm±10%
2.0mm±10%
6×6mm
10% max. of detecting distance
1.2kHz
N.O.
12mA max. (20mA max 3)
IP67 (Use oilresistant cord)
35 to 95%, No condensation
Approx. 40g
Approx. 42g
8
EM-080

WARRANTIES AND DISCLAIMERS

THE FOREGOING, ALL EXPRESS, IMPLIED AND STATUTORY WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. KEYENCE SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES, EVEN IF DAMAGES RESULT FROM THE USE OF THE PRODUCTS IN ACCORDANCE WITH ANY SUGGESTIONS OR INFORMATION PROVIDED BY KEYENCE. In some
urisdictions, some of the foregoing warranty disclaimers or damage limitations
may not apply.
)
2.0mm±10%
10×10mm
Approx. 50g
M10
EM-010
Thread type
4.0mm±10%
Approx. 60g
M14
EM-014
15×15mm
E 1101-3
Influence of surrounding metallic objects
To flush mount the sensor that is embedded in iron, provide enough distance between the sensor and surrounding iron as shown by the following figure and table, because the detecting distance is reduced by 10%.
L
B
Model
EM-030
EM-038
EM-030
EM-030
EM-030
mm
)
(
L
4
4
mm
)
(
A
mm
)
(
B
Note: Consult Keyence regarding nonferrous materials.
4
6
7.6
10
5
5
5
10.8
EM-030
4
5
5
16
20
5
8
8
Align the operation indicator of the amplifier so that it positions at the center of the mounting bracket hole as shown below.
(4
mm
dia)
A
Wiring
EM-030
To extend the cord, use an extension
5
28
8
cord with a conductor cross-sectional area of 0.3mm2. Limit the length of the extension to within 50m. Note that the coaxial cord must not be extended or cut.
Ensure that the sensor cord is kept away from power lines and high­tension lines; otherwise, noise may cause the sensor to malfunction.
Operation indicatormounting bracket hole
Copyright (c) 2008 KEYENCE CORPORATION. All rights reserved. 0202E 1112-2a 96M0202 Printed in Japan
Loading...