96M0202
Specifications
Proximity sensors
with in-cable amplifiers
EM series
Instruction Manual
Output circuit
NPN type
Brown
Load
Black
Proximity
sensors
main circuit
(control output)
Blue
Hints on correct use
Do not use this product for
Warning
■Mounting cylindrical type
● Attach the mounting screw to the sensor
■Mounting thread type
When mounting thread type sensor head,
tightening torque should be less than
specified below.
the purpose of protecting the
human body.
at minimum of 5mm away from the tip
of the sensor.
Be sure to keep the tightening torque
less than 0.4Nm when mounting.
M3 screw
Model
EM-005
EM-010
EM-014
5mm min
Torque
1.5Nm max.
10Nm max.
20Nm max.
DC10.8 to 30V
0V
PNP type
Brown
Black
Proximity
sensors
main circuit
(control output)
Blue
■Mutual interference
When installing a number of proximity
sensors of the same model either face-toface or side-by-side, provide the minimum
distance given in the table between each
sensor.
The values enclosed in brackets are
Note :
when a different frequency type is used.
Face-to-face
Distance
installation
Model
EM-030
EM-038
EM-005
EM-054
EM-080
EM-010
EM-014
Two types with different frequencies available.
(A) or (B) is written after each type name.
12(1)
15(1)
12(1.5)
20(1.5)
24(2.5)
20(2.5)
40(4.5)
■Installing amplifier unit
A mounting bracket is
supplied as a standard
accessory. Use it to secure
the amplifier unit.
✽Do not use setscrews to
secure the amplifier unit.
(
)
installation
11
12
13
18
23
25
34
Load
Side-by-side
DC10.8 to 30V
0V
(
(contact installation)
(contact installation)
(contact installation)
(contact installation)
(contact installation)
(contact installation)
(contact installation)
Type
Shape
Model
Detecting distance
Target
Standard target
mm
[iron, t=(1
Hysteresis
Response frequency
Output mode
Temperature drift
Control output
Rating Environmental durability
Supply voltage
Current
consumption
Degree of
protection
Ambient
operating
temperature
Relative
humidity
Head case material
Weight(nuts and
2 meter-long
cable included)
1 PNP output types are different models from NPN output types and specified by letter P at the end of the model
numbers.(Ex : EM-030P)
2 Use a power range between 10.8 and 30V if ripple occurs.
3 The figures in ( ) are for PNP output type.
Cylindrical Cylindrical
3
3.8
EM-038
0.8mm±15%
1.0mm±15%
Ferrous metals (See catalog for nonferrous metals)
5×5mm
±10% of detecting distance at 23˚C (73˚F) [-10 to +70˚C (-13 to +158˚F)]
NPN open-collector 200mA max. (40V max.) Residual voltage : 1V max.
PNP open-collector 200mA max. (30V max.) Residual voltage : 1V max. 1
10.8 to 30VDC, Ripple(P-P) : 10%max. 2
-25 to +80˚C (-1 to +176˚F), No freezing
Stainless steel Chromium plates brass
Approx. 38g
)]
EM-030
0.6mm±15%
Approx. 36g
Shielded
Thread
type
M5
EM-005
5.4
EM-054
1.2mm±10%
2.0mm±10%
6×6mm
10% max. of detecting distance
1.2kHz
N.O.
12mA max. (20mA max 3)
IP67 (Use oilresistant cord)
35 to 95%, No condensation
Approx. 40g
Approx. 42g
8
EM-080
WARRANTIES AND DISCLAIMERS
KEYENCE, at its sole option, will refund, repair or replace at no charge any
defective Products within 1 year from the date of shipment. Unless stated
otherwise herein, the Products should not be used internally in humans, for
human transportation, as safety devices or fail-safe systems. EXCEPT FOR
THE FOREGOING, ALL EXPRESS, IMPLIED AND STATUTORY
WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF
PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. KEYENCE
SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
CONSEQUENTIAL OR OTHER DAMAGES, EVEN IF DAMAGES RESULT
FROM THE USE OF THE PRODUCTS IN ACCORDANCE WITH ANY
SUGGESTIONS OR INFORMATION PROVIDED BY KEYENCE. In some
urisdictions, some of the foregoing warranty disclaimers or damage limitations
may not apply.
)
2.0mm±10%
10×10mm
Approx. 50g
M10
EM-010
Thread type
4.0mm±10%
Approx. 60g
M14
EM-014
15×15mm
E 1101-3
Influence of surrounding metallic
objects
● To flush mount the sensor that is
embedded in iron, provide enough
distance between the sensor and
surrounding iron as shown by the
following figure and table, because the
detecting distance is reduced by 10%.
L
B
Model
EM-030
EM-038
EM-030
EM-030
EM-030
mm
)
(
L
4
4
mm
)
(
A
mm
)
(
B
Note: Consult Keyence regarding nonferrous materials.
4
6
7.6
10
5
5
5
10.8
EM-030
4
5
5
16
20
5
8
8
Align the operation indicator of the
amplifier so that it positions at the center of
the mounting bracket hole as shown
below.
(4
mm
dia)
A
■Wiring
EM-030
● To extend the cord, use an extension
5
28
8
cord with a conductor cross-sectional
area of 0.3mm2. Limit the length of the
extension to within 50m. Note that the
coaxial cord must not be extended or
cut.
● Ensure that the sensor cord is kept
away from power lines and hightension lines; otherwise, noise may
cause the sensor to malfunction.
Operation indicatormounting bracket hole
Copyright (c) 2008 KEYENCE CORPORATION. All rights reserved.
0202E 1112-2a 96M0202
Printed in Japan