KEYENCE CA-MP120 User Manual

DANGER
WARNING
CAUTION
NOTICE
Reference
WARNING
CAUTION
NOTICE
CAUTION
NOTICE
CAUTION
CAUTION
NOTICE
PANEL LOCK EXIT MENU
24V DC= RGB IN
PANEL LOCK display MENU button
+ button
- button EXIT button PANEL LOCK button
Image signal input
Input connector for image signal
Power input terminal
Power connection terminal for the 24 VDC
(1.5 A)
96M11941
LCD Monitor
CA-MP120
Instruction Manual
Read this manual before using the product in order to achieve maximum performance. Keep this manual in a safe place after reading it so that it can be used at any time.
When using a switching regulator, make sure to ground the frame GND terminal or GND terminal of the power supply. In addition, it is recommended that the CA-MP120 be operate d singly from a power source.

Installation Location

When installing the CA-MP120, make sure to avoid locations with the following conditions.
• Locations where the CA-MP120 is exposed to direct sunlight
• Locations where the ambient temperature exceeds t he range of 0 to +40°C (32 to 104°C), or where the temperature changes dramatically
• Locations with poor ventilation
• Locations where the relative humidity exceeds the range of 35 to 85%, or condensation occurs
• Locations where corrosive or flammable gas exists
• Locations where a large amount of dust, salt, or ferrous powder exists
• Locations where water, oil, or chemicals may splash onto the CA-MP120
• Locations where the CA-MP120 is subjected directly to vibration or impact
• Locations where radiation noise and static electricity may affect operation of the CA-MP120
• Locate the CA-MP120 and cables as far as possible from high-voltage lines and power lines. Otherwise, generated noise may cause product malfunction or equipment failure

Introduction

Symbols

This manual uses the following symbols so that you can recognize important messages at a glance. Please read it in its entirety.
It indicates a hazardous situation which, if not avoided, will result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
It indicates a situation which, if not avoided, could result in product damage as well as property damage.
It indicates tips for better understanding or useful information.

Safety Information for the CA-MP120

General Precautions

• Do not use this product for the purpose of protecting a human body or a part of a human body.
• This product is not intended for use as explosion-proof product. Do not use this product in a hazardous location and/or potentially explosive atmosphere.
• When beginning or during operation, ensure that the par ts and functions are operating correctly.
• In the unlikely event of malfunction, ensure that the proper safety equipment is in place to prevent damage to other equipment.
• Please be aware that the functions and performance of the CA-MP120 will not be guaranteed when the product is disassembled or modified, or if used in any way other than described in the specifications.
• When the CA-MP120 is used in combination with other instruments, its functions and performance may be degraded to an unsatisfactory level. Make sure to examine its performance before starting the operation.

Handling

• Do not disassemble or modify the CA-MP120, as this may cause fire, electric shock, or equipment failure.
Turn the power off immediately if one of the following conditions occur. Continuous use under abnormal conditions may cause fire, electric shock, or equipment failure. Please contact your nearest KEYENCE office for repairs.
- When liquid or a foreign material (such as water, oil, or chemical)
enters the product
- When a strong shock is applied to the product or its housing is
damaged
- When you notice smoke, an unusual smell, or noise coming from
the product CE
• Make sure to turn off power to the CA-MP120 and any connected devices before connecting or disconnecting the cables. Otherwise, the CA-MP120 and connected devices may become damaged.
• If a large amount of dir t or dust accumulates on the CA-MP120, remove it using a tightly squeezed cloth moistened with a dilute solution of neutral detergent. Wipe the unit with a soft, dry cloth. Do not wipe the CA-MP120 with a damp cloth or a cloth moistened with benzine, thinner, or alcohol, as this may cause discoloration or deformation of the unit.

Part Names and Usage

Precautions on Regulations and Standards

CE Marking

Keyence Corporation has confirmed that this product complies with the essential requirements of the applicable EC Directive, based on the following spec ifications. Be sure to consider the following specifications when using this product in the Member State of European Union.
z EMC Directive (2004/108/EC)
• Applicable standard EMI: EN61326-1, ClassA
• The length of cable connected to the power input terminal must be less than 30 m.
Remarks: These specifications do not give any guarantee that the end-product with this product incorporated complies with the essential requirements of EMC Directive. The manufacturer of the end-product is solely responsible for the compliance on the end-product itself according to EMC Directive.

Checking the Package Contents

The CA-MP120 package includes the following parts and equipment. Verify that all parts and equipment are included in the package.
Color LCD monitor CA-MP120 .......................................1
Instruction Manual (This manual) ...................................1
Panel mounting brackets ................................................6
* We have thoroughly inspected the package contents before shipment.
However, in the event of defective or missing items, please contact your nearest KEYENCE sales office.

Hints on Correct Use

Power supply

Do not use the CA-MP120 with a voltage other than 24 VDC, as this may cause fire, electric shock, or equipment failure.
EMS: EN61326-1
1

Connecting to the controller

Panel (Panel thickness): 1.0 to 4.0 mm
2
1
Mounting hook
Screw
Mounting bracket
Mounting bracket
Phillips screwdriver
NOTICE
NOTICE
5.8 mm or smaller
Circular connector
Reference
MENU
MENU
MENU
EXIT
Reference

PANEL LOCK

Reference
(49.5)
6
186
(Active display area)
247.4
(Active display area)
360
15
6.5
255
55.5
28
342
240
35
75
75
4-M4 Depth: 10
(Unit: mm)
Mounting screw
Mounting bracket
157.5
242
+1 0
344
+1
0
Panel thickness 1.6 to 4.0 mm
263
(Mounting bracket
external dimensions)
156.5
(Unit: mm)
Image signal input
Connect by using an RGB monitor cable OP-66842 (3 m), an OP-87055 (10 m), or a commercially available analog RGB cable.
PANEL LOCK
1. The PANEL LOCK will activate when the automatic adjustment indicator lights up.
2. The PANEL LOCK will be deactivated when the PANEL LOCK button is pressed.

Installation Procedure

1. Insert the CA-MP120 into the panel.
2. Using the 6 installation hooks on the top and bottom of the CA-MP120, ti ghten the screws of the mounting bracket using a Phyllis-head screwdriver.
• Tightening the mounting bracket with excessive force may deform the casing. The proper tightening torque for achieving the drip-proof feature is 0.3 Nm. However, note that a drip-proof effect may not be obtained depending on the strength or shape of the panel.
• When installing the CA-MP120, make sure to leave a minimum clearance of 20 mm around the product.
The CA-MP120 can not only be installed to the panel bracket, it can be installed to the monitor stand for CA Series LCD monitor use (optional). For details inquire to your nearest KEYENCE office.

Connecting the 24 VDC Power Source

• Use electrical wiring AWG14 to AWG22.
• Make sure to connect the frame ground terminal for the 24 VDC power source to a type D ground.
• The sizes of solderless connectors are shown below. Use connectors that fit M3 screws.
• Tighten the screws with a torque of 0.5 to 0.75 Nm.
Y connector
5.8 mm or smaller

Adjustment Procedure

If your monitor needs adjustment due to ambient light, the installation angle, or the characteristics of the connected device, follow the procedure below.
When no video signal is input, a blue screen (with message "NO SYNC SIGNAL" for the first five minutes) is displayed instead of the setting menu.
1. Press the button on the rear of the monitor. The setting menu is displayed.
2. Press the button to move the cursor onto the item to change the setting.
3. Press the button to change the setting of the item.
4. Press the button to change the value/setting.
5. Press the button to return to the status of step 1.
6. When you complete the adjustment, press the button to exit the setting menu.
Auto-escape function
If no button is pressed for about 10 seconds, the setting menu display is turned off. When this occurs, the change(s) made so far will be saved.
Item Setting
BRIGHTNESS Adjusts the brightness of the backlight of the LCD panel.
CONTRAST Adjusts the contrast of the image.
COLOR MODE Adjusts the color tone of RGB individually.
BLACK LEVEL Adjusts the black level.
CLOCK
FOCUS
Adjusts the horizontal size of the screen by adjusting the clock.
Reduces blurred characters and images by adjusting the focus.
POSITION Adjusts the horizontal/vertical position of the screen.
AUTO ADJUSTMENT
POWER SAVING
BUTTON LOCK
The input image signal is adjusted automatically to the most appropriate setting. Adjustment object: POSITION/CLOCK/FOCUS
The screen is set when the screen automatically lights up or when the PANEL LOCK is set. The PANEL LOCK is deactivated by the button.
All button operations are deactivated. Also the button operation is deactivated. The lock is released when the button is pressed for 3 seconds or more.
PANEL LOCK
MENU
INFORMATION Displays the device setting information, etc.
RECALL Resets the settings to the factory default (initial) settings.

Specifications

Product name LCD Monitor
Model CA-MP120
Display element a-Si, TFT active matrix method
Display color 16,777,216
No. of dots 1024 (W) x 768 (H) dots or 800 (W) x 600 (H) dots
Active display area
Backlight
Input signal
Input signal mode
245 (W) x 184 (H) mm
Approx. 100,000 hours (average) (When installed in an upright position under 25°C (77°F)) Analog RGB signal (0.7 Vp-p, 75 Ω), Horizontal/vertical synchronization signal 1024 (W) x 768 (H), Vertical frequency: 60 Hz or 800 (W) x 600 (H), Vertical frequency: 60 Hz
Input connector High-density D-sub 15-pin female (3-way, inch screw)
Power-supply voltage 24 VDC ±10%
Current consumption 1.5 A max.
Ambient temperature 0 to +40°C (32 to 104°F)
Relative humidity 35 to 85%
Construction
Panel-mount type Only the front face is dust-proof and splashproof equivalent to IP65
Weight Approx. 2.3 kg
The TFT LCD panels may have bright dots that always illuminate and dark dots that never illuminate. This is inevitable due to the manufacturing process and is not a product failure.

Dimensions

LCD monitor CA-MP120
*1
Panel mounting diagram Panel cut measurement
2
Loading...
+ 2 hidden pages