Precautions

Introduction

This caution sheet describes the precautionary points for using the Macro Lens for the Line Scan Camera CA-LM0210/CA-LML0210. Read this caution sheet before using the product in order to achieve maximum performance. Keep this caution sheet in a safe place after reading it so that it can be used at any time.
This caution sheet uses the following symbols so that you can recognize important messages at aglance. Please read it in its entirety.
It indicates a situation which, if not avoided, could result in product damage as well as property damage.

Precautions Concerning Installation

• When installing this device, always secure the Lens Main Unit side at the specified
• If secured at one spot on the Lens Main Unit side or Camera side only, due to falling etc., an
• This device is a precision device, take preventative measures in an environment
• Use such things as an insulating base when installing the equipment. Ensure that the
• For fixing the Lens Main Unit, do so using the 2 points specified below. If it is fixed using points
Fixing points of the Main Unit (In the case of the CA-LM0210. However, the CA-LML0210 is the same)
Fix to the surrounding gray points using the Macro Lens dedicated mounting stand or a stand with a similar structure.
.
points (surrounding 2 points) using the Macro Lens dedicated mounting stand (OP-87337: optional) or a stand with a similar structure.
accident or malfunction may occur and may be the cause of damage. Please do not do so.
where vibration or shock will contact the device. If an environment where vibration and shock contacting the device continues, it may cause malfunction or damage.
equipment insulation is secured. Since the Lens and the Camera are case grounded, when there is a difference in potential or there is noise and when installed directly without secured insulation, it may be the cause of device damage or incorrect operation.
other than those specified, it may cause damage to the Main Unit or interfere with operation.
1
Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.
11638E 1031-1 96M11638 Printed in Japan

Installation Example of the Macro Lens Dedicated Mounting Stand

58 37.6
68
79
94
62
141.1
(142.4)
34.75
(50)
LENS Center
Stand Main Unit screw positions
7.6
(30)
• Installation example using the Macro Lens dedicated mounting stand (OP-87337)
• When used with the CA-LM(L)0210, XG-HL02M/HL04M/HL08M
2