31.1
16.8
33.9
100.1
32.9
100.4* 17.526
3.5
C-mount
1-32 UNF
φ39.5
φ50.0
* This varies depending on the focal magnification.
Extension amount: 0 to 21.2 mm (the extension amount is at its maximum value when the magnification is at its maximum value).
31.1
6.5
31.0
3.5
17.526
113.4
44.8
114.0*
C-mount
1-32 UNF
φ42.0
φ50.0
* This varies depending on the focal magnification.
Extension amount: 0 to 10 mm (the extension amount is at its maximum value when the magnification is at its maximum value).
50.5
41.5
30.6
3.5
17.526
126.0
34.3
127.0*
C-mount
1-32 UNF
φ44.0
φ48.0
* This varies depending on the focal magnification.
Extension amount: 0 to 20.6 mm (the extension amount is at its maximum value when the magnification is at its maximum value).
CA-LMHR08 CA-LMHR13
CA-LMHR20
96M13064

Specifications

Ultra High-resolution Telecentric Macro Lens
CA-LMHR Series
Instruction Manual
Before using this lens unit, be sure to thoroughly read this Instruction Manual. After you are finished with this Instruction Manual, be sure to store it in a safe place for quick reference.

Checking the Package Contents

This package includes the following items. Make sure that all of the items are in the package.
CA-LMHR08/CA-LMHR13/CA-LMHR20 (Lens)............................................... 1
Instruction Manual (this document)

Safety Precautions

Symbols
The following symbols are used for the list of precautions to ensure safety and to prevent personal injury and/or property damage when using the device.
It indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
It indicates a situation which, if not avoided, could result in product damage as well as property damage.
It indicates additional information on proper operation.
Model CA-LMHR08 CA-LMHR13 CA-LMHR20
Pixel resolution (US 3.5 μm: low magnification to US 4.4 μm: high magnification)
*1
5 μm/pixel 3 μm/pixel 2 μm/pixel
Optical magnification x0.69 to x0.88 x1.15 to x1.47 x1.73 to x2.20
WD (with standard
magnification)
Low magnification 111.0 mm 111.6 mm 114.8 mm
High magnification 111.0 mm 111.6 mm 109.4 mm
*2
Maximum supported image size 2/3-inch
Captured field of view
Effective f­stop
2/3" (Low magnification)
1/1.8" (High magnification)
Low magnification 5.6 to 23 5.7 to 38 6.8 to 43
High magnification 7.1 to 29 7.3 to 49 8.7 to 55
12.2 mm x
10.3 mm
8.0 mm x
6.0 mm
7.3 mm x
6.2 mm
4.8 mm x
3.6 mm
4.8 mm x
4.1 mm
3.2 mm x
2.4 mm
Resolving power Center/periphery: 120 cycles/mm
Resolution
TV distortion
Depth of
*4
field
*3
Low magnification 0.005% 0.011% 0.001%
High magnification -0.001% -0.015% 0.011%
Low magnification 2.689 mm 0.968 mm 0.428 mm
High magnification 1.653 mm 0.592 mm 0.264 mm
5.4 μm 3.3 μm 2.6 μm
Mount C-mount
Ambient temperature and humidity ranges
0 to 50°C, 35 to 80%RH (No condensation)
Weight Approx. 285 g Approx. 330 g Approx. 410 g
*1 The pixel resolution is the field of view per pixel. This varies depending on the camera used.
US = Unit cell size (size of 1 pixel of the receiving element)
*2 WD indicates the distance from the tip of the lens to the workpiece. Changing the
magnification changes this distance. *3 The resolution indicates a theoretical value calculated at 550 nm. *4 The depth of field is a theoretical value calculated with an effective f-value of 16 and a circle
of least confusion of 40 μm. This varies depending on the f-value.
All the above specifications are values based on the optical design, so there may be differences based on factors such as assembly precision.

Tips on Correct Use

Do not look at light sources through the lens. Doing so may cause eye damage .
Installation
Do not use the CA-LMHR Series in the following locations:
• Locations where the CA-LMHR Series is exposed to direct sunlight.
• Locations where the ambient temperature exceeds or drops below the specification rang e, or where the temperature chang es rapidly.
• Locations which are poorly ventilated.
• Locations where the relative humidity drops below 35% or exceeds 85% RH, or where condensations occurs.
• Locations where there are corrosive gas or flammable gas.
• Locations where there are much dust, sodium, or iron powder.
• Locations where water, oil, or chemicals may splash onto the CA-LMHR Series.
• Locations where the CA-LMHR Series may be directly subjected to vibration or impact.
Handling
• In case of transportation, use the same packaging as when the unit was delivered to avoid damage.
• Take care not to dirty the surface of the lens and do not touch it with your hands.
• If the surface of the lens is dirty, clean it using a commercially available lens cleaning kit.
Installation method
• When installing this product, be sure to fix the camera side and the lens side in place at the two locations indicated (as shown in the dimensions diagrams).
• Never fix in place only the camera or the lens, as doing so may lead to the lens falling off of the camera, which may lead to accidents, failures, and damage.
• To fix the lens in place, apply uniform pressure at the indicated locations. Never fix the lens in place at locations other than those indicated or use a method that applies pressure in a single location such as a setscrew. Doing so may lead to product failures or damage.
• This is a precision instrument, so if you will use this product in an environment that will subject it to direct vibrations or impacts, implement appropriate vibration proofing countermeasures. Continually using this product in an environment that subjects it to vibrations or impacts may lead to product failures or damage.
• If you will attach this product to a piece of equipment, use an insulated attachment base or similar device to ensure that this product is insulated from the equipment. The lens and camera are grounded through their frames, so installing these products without guaranteeing insulation in a location in which electric potential differences and noise are present may lead to equipment damage and malfunctions.
With this product, changing the magnification causes the position of the lens on the camera mount to change. Therefore, fix the lens in place after you have finished setting the magnification.

Dimensions

Specified fixing locations on the device
Fix the lens at the locations indicated with shade in the front.