Precautions

Introduction

This caution sheet describes the precautionary points for using the Telecentric Macro Lens CA-LM0307. Read this caution sheet before using the product in order to achieve maximum performance. Keep this caution sheet in a safe place after reading it so that it can be used at any time.

Symbols

NOTICE
It indicates a situation which, if not avoided, could result in product damage as well as property damage.

Precautions Concerning Installation

• When installing this device, always secure the Lens Main Unit side at the specified
• If secured at one spot on the Lens Main Unit side or Camera side only, due to falling etc., an
• This device is a precision device, take preventative measures in an environment
NOTICE
• Use such things as an insulating base when installing the equipment. Ensure that the
• For fixing the Lens Main Unit, do so using the 2 points specified below. If it is fixed using points
Fixing points of the Main Unit
Fix to the surrounding hatching points using the Telecentric Macro Lens dedicated mounting stand or a stand with a similar structure.
.
points (surrounding 2 points) using the Telecentric Macro Lens dedicated mounting stand (OP-87524: optional) or a stand with a similar structure.
accident or malfunction may occur and may be the cause of damage. Please do not do so.
where vibration or shock will contact the device. If an environment where vibration and shock contacting the device continues, it may cause malfunction or damage.
equipment insulation is secured. Since the Lens and the Camera are case grounded, when there is a difference in potential or there is noise and when installed directly without secured insulation, it may be the cause of device damage or incorrect operation.
other than those specified, it may cause damage to the Main Unit or interfere with operation.
C-Mount
3.5
ø48
ø41.8
ø40.6
2-M2
M37.5×0.5
113.2
116.8
ø30
ø40
ø39.8
29.1
50
17.526131.7
1

Installation Example of the Telecentric Macro Lens Dedicated Mounting Stand

• Installation example using the Telecentric Macro Lens dedicated mounting stand (OP-87524)
• Dimensional Outline Drawings
68
LENS Center
Stand Main Unit screw positions
70
0.2 2560
80
41.2
(34.5)
(131.7) (48.3)*
130.7
Unit: mm
6.7
* The above shows the dimension when used with CV-035C/M and XG-035C/M.
In the case of the following combinations, the dimension is (60). When used with CV-200C/M, CV-H035C/M, CV-H100C/M, CV-H200C/M, CV-H500C/M, XG-200C/M, XG-H035C/M, XG-H100C/M, XG-H200C/M and XG-H500C/M
2012