KB Electronics KBVF SERIES Instruction Manual

Installation & Operation Manual
A Complete Line of Motor Drives
KBVF SERIES
Chassis/IP-20 AC Drives
Variable Speed / Soft-Start
with Electronic Motor Overload Protection
Rated for 208-230 Volt 50 & 60 Hz
3-Phase & PSC
from Subfractional thru 1
Operates from 115 and 208/230 Volt
2
50/60 Hz AC Line Input
1
2 HP
3
See Safety Warning, on pages 8 and 9.
This Manual Covers Models
KBVF-21D,22D, 13,23, 23D,23P, 14, 24, 24D, 24P, 26D
The information contained in this manual is intended to be accurate. However, the manufacturer retains the right to make changes in design which may not be included herein.
Notes 1. UL approved as an electronic overload protector for motors. 2. Custom software
is required for PSC motors. See PSC Motor Addendum (Part No. A42142). 3. Do not use this drive with GFCIs. Special software is required — Contact our Sales Department.
4. Requires CE approved RFI /Filter. See RFI Filters & Chokes Selection Guide D-321 (Part No. A42027) for selection of lters to meet the Industrial or Residential Standard.
1
Note: The drive is factory set for
4
60 Hz motors. For 50 Hz motors, see Section 6.2, on page 25.
© 2014 KB Electronics, Inc.
(see back cover)
The QR code link to
this manual is also
located on the drive.
TABLE OF CONTENTS
Section Page
1 Quick-Start Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Safety Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 Important Application Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5 Finger-Safe Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6 Setting Selectable Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7 Mounting Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
8 Recommended High Voltage Dielectric Withstand Testing (Hi-Pot Testing) . . . . . . . . . . . . . . . . . . 28
9 Wiring Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
10 AC Line Fusing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
11 Drive Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
12 Diagnostic LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
13 Trimpot Adjustments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Limited Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Table Page
1 Electrical Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2 General Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3 Fault Recovery and Resetting the Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4 Drive Operating Condition and Status LED Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure Page
1 Quick-Start Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2A Models KBVF-21D, 22D, 13, 23, 23D, 23P, Mechanical Specifications. . . . . . . . . . . . . . . . . . . . . 16
2B Models KBVF-21D, 22D, 13, 23, 23D, 23P Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . 17
ii
TABLE OF CONTENTS (Continued)
Figure Page
3A Models KBVF-14, 24, 24D, 24P, 26D Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 18
3B Models KBVF-14, 24, 24D, 24P, 26D Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 19
4 Expanded View of Jumpers and Trimpots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5 Maximum Allowed Motor Torque vs. Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6 Open Ventilated Motor with External Cooling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7 Models KBVF-21D, 22D, 23D, 24D AC Line Input Voltage Selection. . . . . . . . . . . . . . . . . . . . . . 24
8 Model KBVF-26D AC Line Input Voltage Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
9 Removing Jumper J1 on Model KBVF-26D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
10 60 Hz and 50 Hz Motor Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
11 Available Torque vs. Output Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
12 120 Hz and 100 Hz Drive Output Frequency Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
13 Automatic Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
14 Forward/Reverse Speed Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
15 Typical Hi-Pot Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
16 AC Line Input, Motor, and Ground Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
17 Main Speed Potentiometer Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
18 Voltage Following Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
19 Manual Start Switch Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
20 Forward-Stop-Reverse Switch Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
21 Enable Switch connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
22 Minimum Speed Trimpot (MIN) Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
23 Maximum Speed Trimpot (MAX) Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
24 Acceleration Trimpot (ACC) Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
25 Deceleration Trimpot (DEC/B) Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
26 Slip Compensation Trimpot (COMP) Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
iii
TABLE OF CONTENTS (Continued)
Figure Page
27 Boost Trimpot (DEC/B) Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
28 Model KBVF-21D Current Limit Trimpot (CL) Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
29 Model KBVF-22D Current Limit Trimpot (CL) Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
30 Models KBVF-13, 23, 23D, 23P Current Limit Trimpot (CL) Range . . . . . . . . . . . . . . . . . . . . . . . . 43
31 Models KBVF-14, 24, 24D, 24P Current Limit Trimpot (CL) Range . . . . . . . . . . . . . . . . . . . . . . . . 43
32 Model KBVF-26D Current Limit Trimpot (CL) Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Items Included in this Package:
KBVF Adjustable Frequency Drive, KBVF Series Installation and Operation Manual, Main Speed Potentiometer Kit with Insulator and Mounting Hardware, Main Speed Potentiometer Terminals (3 Orange), Motor and AC Line Terminals (5 Blue), 2-Wire and 3-Wire Connector Kit, Status Indicator Label, Trimpot Adjustment Tool, CE Approved Product Information Card, Warranty Registration Card.
UL Notice
230 VAC Controls
Suitable For Use On A Circuit Capable Of Delivering Not More Than 5 kA RMS Symmetrical Amperes, 230 Volts Maximum. Use Copper Conductors Rated 75 ºC. Suitable for Operation in a Maximum Surrounding Air Temperature of 40 ºC.
RECONDITIONING THE BUS CAPACITORS
If this drive has been in storage for over one year it is necessary to recondition the power supply bus capacitors. To recondition the bus capacitors, apply the AC Line, with the drive in the Stop Mode, for a minimum of one hour. Not following this procedure will cause the bus capacitors to fail.
iv
FIGURE 1 – QUICK-START CONNECTION DIAGRAM
L2W L1U V
see Section 3.5, on page 13.
Communication Port for Accessories and Programming:
see Section 9.1,
on page 30.
Single-Phase, 50/60 Hz
AC Line Input:
see Section 9.3,
on page 31.
Motor Connection:
see Section 9.2,
on page 31.
Ground (Earth):
For 60 Hz or 50 Hz Motor Operation:
For Two Times the Rated Motor RPM:
see Section 6.2.1, on page 25.
see Section 6.2.2, on page 25.
see Section 6.3, on page 26.
Automatic Start:
see Section 9.6, on page 33.
Manual Start Switch Connection:
Forward/Reverse Speed Selection:
Forward-Stop-Reverse Switch Connection:
Voltage Following Signal Input
in Lieu of Main Speed Potentiometer:
see Section 12, on page 37.
see Section 6.4, on page 27.
see Section 9.7, on page 34.
see Section 9.5, on page 32.
Diagnostic LEDs:
see Section 9.8, on page 35.
Enable Switch Connection,
AC Line Input Voltage Selection
Main Speed Potentiometer (5 K)
see Section 9.4, on page 31.
(Supplied) (Front View):
(Dual Voltage Models Only):
see Section 13, on page 38 .
Adjustable Trimpots:
see Section 6.1, on page 24.
High
Wiper
Low
Chassis
B+
AC LINEMOTOR
B-
J1
CON3
J2
PWR
ST
50/60Hz
F - S - R
CON2
A/M
J1
P2 P3
CON1
X1 X2
P1
DEC/BMINMAXCL ACC COMP
230V 115V
Motor
(Model KBVF-22D Shown)
5
1 QUICK-START INSTRUCTIONS
Important – You must read these simplified instructions before proceeding. These instruc­tions are to be used as a reference only and are not intended to replace the details pro­vided herein. You must read the Safety Warning on, pages 8 and 9, before proceeding.
See Figure 1 on page 5. Also see Section 4 – Important Application Information, on page 20.
WARNING! Disconnect main power before making connections to the drive.
1.1 AC Line Connection – Wire the AC line input as described below and as shown in Figure 16
on page 31. See Section 9.1, on page 30.
Application Note: Do not wire this drive to a GFCI. If operation with a GFCI is required, contact our Sales Department.
Models KBVF-13, 14 – Rated for 115 Volt AC line input only. Wire the single-phase AC line input to Terminals “L1” and “L2”.
Models KBVF-23, 24 – Rated for 208/230 Volt AC line input only. Wire the single-phase AC line input to Terminals “L1” and “L2”
Models KBVF-21D, 22D, 23D, 24D, 26D* – Rated for 208/230 Volt AC line input with Jumper J1 (on upper PC board) set to the “230V” position (factory setting). Rated for 115 Volt AC line input with Jumper J1 (on upper PC board) set to the “115V” position. Wire the single­phase AC line input to Terminals “L1” and “L2”
*On Model KBVF-26D, Jumper J1 is labeled “115VAC” and “230VAC”.
Models KBVF-23P, 24P – Rated for 208/230 Volt AC line input. Wire the 3-Phase AC line input to Terminals “L1”, “L2”, and “L3”.
6
1.2 Ground Connection – Connect the ground wire (earth) to the ground screw, as shown in
Figure 16, on page 31. See Section 9.2, on page 31.
Note: Model KBVF-21D, due to its double insulated design, does not contain a ground screw.
1.3 AC Line Fusing – It is recommended that a fuse(s) or circuit breaker be installed in the AC
line. Fuse each conductor that is not at ground potential. For the recommended fuse size, see Table 1, on page 14. Also see Section 10, on page 35.
1.4 Motor Connection – Wire the motor to quick-connect Terminals “U”, “V”, “W”, as shown in
Figure 16, on page 31. (Special reactors may be required for cable lengths over 100 ft. (30 m) – consult our Sales Department.) See Section 9.3, on page 31.
Note: The drive is programmed to operate 3-phase AC induction motors. For PSC motors, optional software is required – contact our Sales Department.
1.5 60 Hz and 50 Hz Motor Operation (Jumpers J1 and J2 On the Lower PC Board) – The
drive is factory set for 60 Hz motor operation (Jumper J1 set to the “60Hz” position and Jumper J2 set to the “X1” position). For 50 Hz motor operation, set Jumper J1 to the “50Hz” position and be sure Jumper J2 is set to the “X1” position. See Section 6.2.1, on page 25.
1.6 Trimpot Settings – All trimpots have been factory set for most applications, as shown in
Figure 4, on page 20. Some applications require adjustment of the trimpots in order to tailor the drive for a specific requirement. See Section 13, on page 38.
1.7 Main Speed Potentiometer Connection – For unidirectional speed operation, wire the 5 kΩ
potentiometer (supplied) to Terminals “P1” (low), “P2” (wiper), “P3” (high). See Section 9.4, on page 31.
7
1.8 Voltage Following – An isolated* 0 – 5 Volt DC analog signal input can be used to control
motor speed in lieu of the Main Speed Potentiometer. The drive output will linearly follow the analog signal input. Connect the signal input positive lead (+) to Terminal “P2” and the nega­tive lead (–) to Terminal “P1”. See Section 9.5, on page 32.
*If a non-isolated signal is used, install the SIVFR — Signal Isolator (Part No. 9597). The SIVFR accepts voltage (0 to ±2.5 thru 0 to ±25 Volts DC) or current (4 – 20 mA DC) signal inputs. See Section 3.5, on page 13.
Note: For signal following operation, the Minimum Speed Trimpot (MIN) must be set fully counterclockwise.
WARNING! The signal input must be isolated from the AC line. Earth grounding
signal wiring will damage the drive and void the warranty. It is recommended that the SIVFR — Signal Isolator and Run/Fault Relay (Part No. 9597) be installed when using signal following.
2 SAFETY WARNING
Denition of Safety Warning Symbols
Electrical Hazard Warning Symbol – Failure to observe this warning could result in electrical
shock or electrocution.
Operational Hazard Warning Symbol – Failure to observe this warning could result in serious injury or death.
8
This product should be installed and serviced by a qualified technician, electrician, or electri-
cal maintenance person familiar with its operation and the hazards involved. Proper installa­tion, which includes electrical connections, mounting and adequate enclosure, fusing or other current protection, and grounding can reduce the chance of electrical shocks, and/or fires in this product or products used with this product, such as electric motors, switches, coils, solenoids, and/or relays. Do not use this drive in an explosion-proof application. Eye protection must be worn and insulated adjust­ment tools must be used when working with drive under power. This product is constructed of materi­als (plastics, metals, carbon, silicon, etc.) which may be a potential hazard. Proper shielding, grounding, and filtering of this product can reduce the emission of radio frequency interference (RFI) which may adversely affect sensitive electronic equipment. The input circuits of this drive may not be isolated from the AC line. Be sure to read and follow all instructions carefully. Fire and/or electrocution can result due to improper use of this product. The drive may contain electronic start/stop circuits, which are used for "Start" and "Stop" functions. However, these circuits are never to be used as safety disconnects since they are not fail-safe. Use only the AC line for this purpose.It is the responsibility of the equipment man­ufacturer and individual installer to supply this Safety Warning to the ultimate end user of this product. (SW 7/2009)
This product complies with all CE directives pertinent at the time of manufacture. Contact
our Sales Department for Declaration of Conformity. Installation of a CE approved RFI filter is required. See RFI Filters & Chokes Selection Guide D-321 (Part No. A42027) for selection of filters to meet the Industrial or Residential Standard. Additional shielded cable and/or AC line cables may be required along with a signal isolator (SIVFR (Part No. 9597)).
3 INTRODUCTION
Thank you for purchasing the KBVF Adjustable Frequency Drive. KB Electronics, Inc. is committed to providing total customer satisfaction by producing quality products that are easy to install and operate. The KBVF is manufactured with surface mount components incorporating advanced circuitry and technology. A Finger-Safe Cover is included for added liability protection.
9
The KBVF Adjustable Frequency Drives provide variable speed control for standard 3-phase and Permanent Split Capacitor (PSC)
1
AC induction motors from subfractional thru 11⁄2 HP. The sine wave coded Pulse Width Modulated (PWM) output operates at a carrier frequency of 16 kHz, which provides high motor efficiency and low noise. Adjustable linear acceleration and deceleration are provided, making the drive suitable for soft-start applications.
Due to its user-friendly design, the KBVF AC drive is easy to install and operate. Tailoring to specific applications is accomplished with selectable jumpers and trimpots, which eliminate the computer­like programming required on other drives. However, for most applications no adjustments are nec­essary. For more advanced programming, PC based Drive-Link™ software is available.
2
Main features include adjustable RMS Current Limit and I
t Motor Overload Protection.2In addition, Adjustable Slip Compensation with Static Auto-Tune and Boost provides high torque and excellent load regulation over a wide speed range. Power Start™ delivers over 200% motor torque to ensure startup of high frictional loads. Electronic Inrush Current Limit (EICL™) eliminates harmful AC line inrush current.
3
The drive is suitable for machine or variable torque (HVAC) applications. With option-
al Drive-Link™ software, the drive can be programmed for DC Injection Braking.
For AC line and motor wiring, quick-connect terminals are provided. Other features include adjustable trimpots (MIN, MAX, ACC, DEC/B
4
, COMP CL), customer selectable jumpers (Automatic­Manual Start, Motor Frequency, Frequency Multiplier, Forward/Reverse, and Line Voltage (dual volt­age models only)). Diagnostic LEDs are provided for power (PWR) and drive status (ST). A 5 kΩ Main Speed Potentiometer is also included.
A Signal Isolator is optional on all models, which can be used for single-ended or bidirectional speed control and accepts voltage or current signal input. Other optional accessories include Class “A” and “B” AC Line Filters, Dynamic Brake Module, Multi-Speed Board, Programming Kit, and Modbus Communication Module. A connector is provided for easy installation of accessories.
10
Notes: 1. Optional software is required for PSC motors — contact our Sales Department. 2. UL approved as an electronic overload protector for motors. 3. Models KBVF-21D, 22D contain ICL in lieu of EICL™. 4. In 50 Hz Mode, the DEC/B Trimpot automatically becomes Adjustable Boost.
3.1 Standard Features
• Simple to Operate – Does not require programming. Uses trimpots and jumpers, which are
factory set for most applications.
• Diagnostic LEDs – Power on (PWR) and drive status (ST). See Section 12, on page 37.
• Jumper Selection of Drive Output Frequency – Increases the motor speed up to two
times the rated RPM. See Section 6.2, on page 25.
• Bidirectional Signal Operation (SIVFR Required).
• Compatible with GFCIs (with optional software).
• Industry Standard Mounting. See Section 7, on page 27.
• Finger-Safe Cover – Meets IP-20 standard. See Section 5, on page 22.
3.2 Performance Features
• Power Start™ – Provides more than 200% starting torque which ensures startup of high
frictional loads.
• Slip Compensation with Static Auto-Tune and Boost – Provides excellent load
regulation over a wide speed range.
• Speed Range – 60:1
3.3 Protection Features
2
• Motor Overload (I
t) with RMS Current Limit – Provides motor overload protection
which prevents motor burnout and eliminates nuisance trips. UL approved as an electronic overload protector for motors. See Section 4.2, on page 22, and Section 13.7, on page 42.
11
• Electronic Inrush Current Limit (EICL™) – Eliminates harmful inrush AC line current
during startup. Models KBVF-21D, 22D contain ICL in lieu of EICL™.
• Short Circuit – Prevents drive failure if a short circuit occurs at the motor (phase-to-phase).
• Motor Filter – Reduces harmful voltage spikes to the motor.*
• Regeneration – Eliminates nuisance tripping due to bus overvoltage caused by rapid decel-
eration of high inertial loads.
• Undervoltage and Overvoltage – Shuts down the drive if the AC line input voltage goes
above or below the operating range.
• MOV Input Transient Suppression.
• Microcontroller Self Monitoring and Auto-Reboot.
*Only Models KBVF-21D, 22D, 13, 23, 23D, 14, 24, 24D, 26D Contain Motor Filter.
3.4 Trimpot Adjustments
• Minimum Speed (MIN) – Sets the minimum speed of the motor. See Section. 13.1, on page 39.
• Maximum Speed (MAX) – Sets the maximum speed of the motor. See Section.13.2, on page39.
• Acceleration (ACC) – Sets the amount of time for the motor to accelerate from zero speed
to full speed. See Section 13.3, on page 39.
• Deceleration (DEC/B) – Sets the amount of time for the motor to decelerate from full speed
to zero speed. See Section 13.4, on page 39.
• Slip Compensation (COMP) – Maintains set motor speed under varying loads. See Section
13.5, on page 40.
• Boost (DEC/B) – In 50 Hz mode, the trimpot automatically becomes Adjustable Boost,
which can be used to set the Volts/Hz Curve for 50 Hz motors to obtain maximum perform­ance. In 50 Hz Mode, the deceleration time is automatically set to the same as the accelera­tion time. See Section 13.6, on page 41.
12
• Current Limit (CL) – Sets the current limit (overload) which limits the maximum current
(torque) to the motor. See Section 13.7, on page 42.
3.5 Optional Accessories
• SIVFR — Signal Isolator and Run/Fault Relay (Part No. 9597) – Provides isolation
between a non-isolated signal voltage (0 to ±2.5 thru 0 to ±25 Volts DC) or current source (4 – 20 mA DC) and the drive. Can be used in single-ended or bidirectional mode. Run/Fault Relay Output Contacts are also provided, which can be used to turn on or off equipment or to signal a warning if the drive is put into the Stop Mode or a fault has occurred. Mounts on the end of the drive’s heat sink.
• DBVF — Dynamic Brake Module (Part No. 9598) – Provides up to 25% continuous
braking and 200% instantaneous braking torque (maximum 1 HP (0.75 kW)).
• Multi-Speed Board (Part No. 9503) – Provides multi-speed operation using external
contacts or a PLC. Mounts on the end of the drive’s heat sink.
• Programming Kit (Part No. 9582) – Includes DownLoad Module™ (DLM) handheld
programming device which uploads and downloads drive programs, PC to DLM serial com­munication cable, DLM to inverter communication cable, and PC Windows® based Drive­Link™ communication software. Contact our Sales Department for more information.
• DIVF — Modbus Communication Module (Part No. 9568) – Allows the drive to communi-
cate with PLCs, PCs, and HMIs with Modbus* RTU protocol utilizing a serial communication cable. If a USB communication cable is required, purchase Part No. 19008.
*Other Protocols available. Contact our Sales Department.
• RFI Filters and Chokes – Provide RFI and EMI Suppression. They comply with CE Council
Directive 89/336/EEC relating to the Class A Industrial and Class B Residential Standards. See RFI Filters and Chokes Selection Guide Publication No. D-321 (Part No. A42027).
• Custom Software – All models can be factory programmed for applications that require spe-
cial switching, timing, PLC functions, and GFCI operation. Contact our Sales Department.
13
TABLE 1 – ELECTRICAL RATINGS
AC Line Input
Fuse or
Circuit Breaker
Maximum
Part
Model
KBVF-21D 9581
KBVF-22D 9572
KBVF-13 9957 115 1 9.6 15 0 – 230 2.4 1/2 (.37) 1.3 0.6
KBVF-23 9958 208/230 1 6.0 10 0 – 230 2.4 1/2 (.37) 1.3 0.6
KBVF-23D 9959
KBVF-23P 9676 208/230 3 3.2 5 0 – 230 2.4 1/2 (.37) 1.1 0.5
KBVF-14 9977 115 1 14.0 20 0 – 230 4.0 1 (.75) 2.2 1.0
KBVF-24 9978 208/230 1 10.0 15 0 – 230 4.0 1 (.75) 2.2 1.0
KBVF-24D 9979
KBVF-24P 9677 208/230 3 5.2 10 0 – 230 4.0 1 (.75) 2.0 0.9
KBVF-26D* 9496
*Model KBVF-26D is rated 2 HP (1.5 kW) for most Premium Efficient motors.
Note: All models contain Motor Filter and Quick-Connect Terminals for AC line and motor wiring. The Signal Isolator and Run/Fault Relay is optional on all models.
No.
(50/60 Hz)
Phase
Volts AC
115 1 4.0
208/230 1 2.5
115 1 6.0 10
208/230 1 3.8 5
115 1 9.6 15
208/230 1 6.0 10
115 1 14.0 20
208/230 1 10.0 15
115 1 22.0 25
208/230 1 14.0 20
Current
(φ)
(Amps AC)
Rating
(Amps)
Voltage
Range (Nominal) (Volts AC)
5 0 – 230 1.0 1/10 (.07) 0.7 0.3
0 – 230 1.5 1/4 (.18) 1.3 0.6
0 – 230 2.4 1/2 (.37) 1.3 0.6
0 – 230 4.0 1 (.75) 2.2 1.0
0 – 230 5.5 11⁄2 (1.13) 2.9 1.3
Drive Output
Maximum
Continuous
Load Current
(RMS Amps/Phase)
Maximum
Horsepower
(HP (kW)) lbs kg
Net Wt.
14