Jenn-Air CMV1100AAQ, CMV1100AAB, CMV1100AAW Dimension Guide

0 (0)
Jenn-Air CMV1100AAQ, CMV1100AAB, CMV1100AAW Dimension Guide

www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600

 

 

This Data Sheet Includes Information On

 

 

 

Jenn-Air

 

 

Product Model Number (s):

 

 

Over the Range Microwaves:

 

 

 

CMV1100AAQ, CMV1100AAB and CMV1100AAW

 

Dimensions (Actual Size)

 

 

Unit height:

17"

 

 

 

Unit depth:

14 1/2"

 

 

 

Unit width:

29 7/8"

 

 

 

Recommended opening depth: 13"

 

 

 

Recommended opening width: 30"

 

 

 

Mounting height from floor: 66" Min.

 

 

 

Minimum mounting height

 

 

 

 

from cooking surface: 30"

 

 

 

Distance from unit

22 1/2"

 

 

 

face to open door:

 

 

Additional Information

Electrical requirements: Voltage 120, single phase, 60Hz. AC. Ampere 15 or 20. 2 wire with ground circuit required. Locate outlet box in the cabinet above in the lower right hand corner, cut a 1 1/2" hole in the back right hand corner of the cabinet above for the units cord.

Wall construction should be a minimum of 2"x4" wood studding and 3/8" thickness drywall or plaster/both.

Units are designed for use above all Maytag

non-grilling gas and electric ranges and cooktops (not recommended over grill-ranges or cooktops with grilling capability unless the range or cooktop is equipped with downdraft ventilation).

Outside ventilation requires hood exhaust duct. The hood exhaust has been designed to mate with a standard 3 1/4" x 10" duct. If round is required, a transition adaptor must be used. Do not use less than 6" round duct.

Maximum duct length: The total duct length of 3 1/4" x 10" or 6" round duct should not exceed 140 equivalent feet. When calculating the total duct length add equivalent lengths of all transitions and adaptors plus the lengths of all straight duct sections.

280 Hi/ 180 Low CFM Vertical exhaust (3 1/4" x 10" duct).

300 Hi/ 200 Low CFM Horizontal exhaust (3 1/4" x 10" duct).

See page 2-3 for additional information

Subject to change without notice. This system is designed to

 

be updated daily if necessary. Dimension Express is not

 

responsible for use of superseded, voided, or outdated data

 

sheets. Because of the difficulty or impracticability of deter-

 

mining actual damages, liability of Dimension Express shall

 

not exceed $50.00.

 

Copyright © Dimension Express, 2002.

191

Exhaust outlet connects to

3 1/4" X 10" duct

14 1/2"

29 7/8"

22 1/2"

Door Open

17"

(not to scale)

 

66" Min.

 

 

30"

 

 

Minimum

 

 

 

Minimum

 

 

mounting

 

 

mounting

height from

 

 

height from

 

floor

 

 

cooking

 

 

 

 

 

surface

 

 

 

 

 

 

 

 

 

 

 

13"

30"

Wall View (not to scale)

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

BN • A191B278C150 • • 032603 • 95659 • 42906

associated with reusing old Data Sheets.