www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600

 

This Data Sheet Includes Information On

 

 

 

 

 

 

 

 

 

 

 

30"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jenn-Air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Model Number (s):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30" Gas Cooktops:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 7/16"

 

 

 

 

 

21"

 

 

 

CCG2423Q, CCG2423S, CCG2423B and CCG2423W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side View (not to scale)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions (Actual Size)

 

 

 

 

 

 

 

Overall Dimensions

 

 

Overall width: 30"

 

 

 

 

 

 

 

 

 

 

Top View (not to scale)

 

Overall depth: 21"

Distance from top of counter to bottom of unit: 3 7/16"

 

Cut-Out width: 26 9/16"

 

 

 

Cut-Out Dimensions

 

Cut-Out depth: 20 1/16"

 

 

20 1/16"

 

 

 

Countertop View

Min. spacing from cooktop edge to nearest

 

 

 

 

 

 

(not to scale)

vertical combustible wall to the RIGHT: 2"

 

 

 

 

 

26 9/16"

 

Min. spacing from cooktop edge to nearest

 

 

 

 

 

 

 

vertical combustible wall to the LEFT: 2"

 

 

 

 

Min. spacing from cooktop edge to nearest

 

 

 

 

vertical combustible wall to the REAR: 1 1/2"

 

 

 

 

Minimum spacing to front edge of counter: 2"

 

 

 

 

Minimum distance between cooktop

 

 

 

 

 

and cabinet directly above: 30"

 

 

 

Cabinet Requirements

Minimum

width of cabinet directly above: 30"

 

 

 

Wall View

Maximum depth of cabinets directly

 

 

 

(not to scale)

 

 

 

 

 

above and adjacent: 13"

 

 

30"

 

Minimum distance between countertop

 

 

 

Minimum horizontal

 

and adjacent cabinet above: 18"

 

 

30"

Additional Information

18"

 

clearance between the

 

edge of the appliance

• Electrical requirements : 110/120 volt AC, 60hz. Must

 

 

 

and combustible

be grounded. 15amp circuit required. Locate outlet

 

 

 

 

 

 

construction extending

below the cooktop a minimum of 3" below the

 

 

 

 

 

 

from the cooking

countertop if not installing over an under counter oven.

 

 

 

 

surface to 18" above

Locate outlet below the oven or in an adjacent cabinet

 

 

 

 

 

 

the cooking surface is

when installing over an adjacent under counter oven.

 

 

 

 

 

 

2" (see solid areas)

• Minimum clearance from top of counter to combustible

 

 

 

 

 

material below is 2 5/8"

 

 

 

 

• Countertop must be supported within 3" of cutout.

 

 

 

 

• Unit may be installed over an under counter oven.

 

 

 

 

• Gas requirements : The pressure regulator supplied

 

 

 

 

with this appliance is pre-set and fixed for correct

 

 

 

 

outlet pressure: 5"W.C. if this model is equipped for

 

 

 

 

use with natural gas; 10" W.C. if equipped for use with

 

9/16" to centerline of pipe from

Top view of cutout

when converting to LP. The maximum inlet gas supply

 

back edge of cutout

 

(not to scale)

pressure for the regulator is 14" W.C. The inlet test

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pressure for checking the regulator must be at least 6"

Gas inlet location

 

 

 

 

 

 

 

 

 

 

 

 

W.C if equipped for natural gas; 11" W.C. if converted

 

 

 

 

 

 

 

 

to LP gas.

 

 

 

 

 

 

 

 

 

 

 

 

 

See page 2 for additional information

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 21/32" from left

 

 

 

 

 

 

side of cutout to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Subject to change without notice. This system is designed to

 

 

 

centerline of pipe.

 

 

 

 

 

 

 

 

 

be updated daily if necessary. Dimension Express is not

 

 

 

 

 

 

 

 

 

 

 

 

 

responsible for use of superseded, voided, or outdated data

 

 

 

 

 

 

 

 

 

 

 

 

 

sheets. Because of the difficulty or impracticability of deter-

 

 

 

 

 

 

 

 

 

 

 

 

 

mining actual damages, liability of Dimension Express shall

 

 

 

 

 

 

 

 

 

 

 

 

 

not exceed $50.00.

 

 

 

Cooktop supplied with 1/2" NPT female inlet on regulator

Copyright © Dimension Express, 2002.

321

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• NEVER reuse Data Sheets. Data Sheets are subject to change without

 

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

 

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

 

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

 

 

 

 

 

 

BN182.34 • A321B149 • • 032603 • 95656 • 41867