This product complies with Directive 93/42/EEC concerning medical devices.
Ce produit est conforme à la Directive 93/42/CEE concernant les dispositifs médicaux.
Specifications and Weight Limitation................................................................................................................................................................................................ 4
Scope of Delivery...................................................................................................................................................................................................................................6
General Warnings.................................................................................................................................................................................................................................. 7
Instructions on electromagnetic compatibility................................................................................................................................................................................7
Recharging the Battery ......................................................................................................................................................................................................................... 9
Setting Up the Bathlift in the Bathtub.............................................................................................................................................................................................11
Removing the Bathlift from the Bathtub.........................................................................................................................................................................................12
4USAGE 13
5MAINTENANCE 15
6WARRANTY 17
Limited Warranty - North America................................................................................................................................................................................................17
Customer Service and Warranty Information..............................................................................................................................................................................18
Invacare® Rio™ H6053Part No 1167607
1 GENERAL
The product label is
located on the rear of
the backrest
1212
11
10
9
765438
1 General
1.1Symbols
Signal words are used in this manual and apply to hazards or unsafe practices
which could result in personal injury or property damage. See the information
below for definitions of the signal words.
WARNING
1.2Service Life
The expected service life of this product is five years when used in accordance
with the safety instructions, maintenance intervals and correct use, stated in this
manual. The effective service life can vary according to frequency and intensity of
use.
Maintenance should be done at least every six months.
1.3Specifications and Weight Limitation
The weight limitation of the bath lift is 265 lb (120 kg).
Warning indicates a potentially hazardous situation
which, if not avoided, could result in death or serious
injury.
CAUTION
Caution indicates a potentially hazardous situation which,
if not avoided, may result in property damage or minor
injury or both.
Gives useful tips, recommendations and information for
efficient, trouble-free use.
WARNING
ALWAYS observe the weight limit on the labeling of your
product. Check that all labels are present and legible. Replace
if necessary.
1.4Product Labeling
1Manufacturer’s Data7Load Capacity
2Conformity Marking8Serial Number
Nominal voltage/nomi-
3
4
5Protection class11Type designation
6
nal consumption9
duty cycle (max. 10%,
max. 2 min/18 min)10Date of manufacture
Application part of
type B12Disposal instructions
Follow the operating
instructions
Invacare®
Rio™ H6054Part No 1167607
1 GENERAL
1.5Technical Data
Overall Depth (lower end position)26.8 in680 mm
Total Height (upper end position)40.6 in1030 mm
Height of Seat 2.4 - 17.3 in60 mm - 440 mm
Width of Seat (without/with flaps)14.6 in / 28.3 in370 mm / 720 mm
Width of Backrest13.8-15.7 in350-400 mm
Height of Backrest24.2 in615 mm
Depth of Seat17.3 in440 mm
Angle of Seat105°
Total Weight (without battery)20.9 lb9.5 kg
Weight of battery3.5 lb1.6 kg
Battery typeLead-acid gel 12 V 3 Ah
Charger input / output120 V AC; 50 Hz / 12 V DC; 0.4 A
Charging timemax 5 h
Drive protection classIP66W
Pendant control protection classIP67
Sound power level 52dB(A)
Actuating force for pendant control buttons< 5 N
Part No 1167607
5Invacare®
Rio™ H605
2 SAFETY
ABathtub length at bottommin. 31.5 inmin. 80 cm
BBathtub width at bottom (inside)min. 14.2 inmin. 36 cm
HBathtub height inside (without
optional height adapters)
max. 17.3 inmax. 44 cm
Bathtub height inside (with
optional height adapters
max. 18.9 inmax. 48 cm
EBathtub width outsidemax. 27.6 inmax. 70 cm
2 Safety
2.1Scope of Delivery
Check ALL parts for shipping damage. If shipping damage is
noted, DO NOT use. Contact carrier/dealer for further
instruction.
If possible, keep the original packaging for transportation at a later date.
Invacare®
Rio™ H6056Part No 1167607
2.2Intended Use
The bathlift is intended for lowering a person into a bathtub and lifting a person
out of a bathtub only. All other use can cause risk of injury. Only use the bathlift
in bathtubs of the specified size:
2.3General Warnings
WARNING
DO NOT USE THIS PRODUCT OR ANY AVAILABLE
OPTIONAL EQUIPMENT WITHOUT FIRST
COMPLETELY READING AND UNDERSTANDING
THESE INSTRUCTIONS AND ANY ADDITIONAL
INSTRUCTIONAL MATERIAL SUCH AS OWNER’S
MANUALS, SERVICE MANUALS OR INSTRUCTION
SHEETS SUPPLIED WITH THIS PRODUCT OR
OPTIONAL EQUIPMENT. IF YOU ARE UNABLE TO
UNDERSTAND THE WARNINGS, CAUTIONS OR
INSTRUCTIONS, CONTACT A HEALTHCARE
PROFESSIONAL, DEALER OR TECHNICAL PERSONNEL
BEFORE ATTEMPTING TO USE THIS EQUIPMENT OTHERWISE, INJURY OR DAMAGE MAY OCCUR.
ACCESSORIES WARNING
Invacare products are specifically designed and manufactured
for use in conjunction with Invacare accessories. Accessories
designed by other manufacturers have not been tested by
Invacare and are not recommended for use with Invacare
products.
WARNING
Risk of Injury
If your state of health does not allow you to bathe on your
own, ALWAYS take a bath under supervision.
DO NOT make any unauthorized alterations or conversions
to the device.
2 SAFETY
CAUTION
2.4Instructions on electromagnetic compatibility
Even if all applicable EMC guidelines and standards are complied with, it
is possible that the bathlift could be impaired by other electrical devices
(e.g. mobile telephones, CB radio devices, portable radios) or that the
lift could impair these devices. If you note any such interference, switch
off the other device and/or the bathlift. If you carry other electrically
operated medical products on your person and these products cause
interference or are impaired, switch off the bathlift and contact your
specialist dealer. For more information about the electromagnetic
characteristics, see the Technical data section.
Risk of Damage
DO NOT expose the product to direct sunlight.
Only transport or store the product in dry spaces at
temperatures between 0°C and 40°C, an air pressure
between 860 and 1060 hPa and an air humidity between 30%
and 75%.
Note the information on the product label.
Only load the bathlift up to the specified maximum user
weight. If you overload the bathlift , it could result in damage
to the device.
Part No 1167607
7Invacare®
Rio™ H605
2 SAFETY
2.5Battery Warnings
WARNING
Risk of Injury
Only use original batteries in the device (Invacare H605 Rio
Battery).
Only charge the battery with the original charger (Invacare
H605 Rio plug-in charger).
Replace batteries with a greatly reduced output (range) in
good time.
Do not open or alter the power adapter or the battery.
Before cleaning the charger, always disconnect the power
adapter from the power socket.
Never throw the battery into fire and do not store the
battery near fire.
If the battery becomes damaged and diluted sulphuric acid
comes into contact with eyes, wash eyes immediately with
copious amounts of water and see a doctor without delay.
If the battery becomes damaged and diluted sulphuric acid
comes into contact with skin or clothing, thoroughly wash the
affected area immediately with water.
CAUTION
Risk of Damage
Do not touch the battery’s contacts with electrically
conductive objects as this could damage the battery (short
circuit).
Invacare®
Rio™ H6058Part No 1167607
3 Setup
~
1
3
2
3.1Recharging the Battery
WARNING
•Recharge the battery after each use of the device.
•Only charge the battery in a dry room, never in the bathroom.
•When charging, ensure that there is sufficient ventilation in the
•The charging time is a maximum of 5 hours.
•You cannot overcharge the battery; the charger switches off
•If not using the device, charge the battery at least once a month.
•After charging the battery, disconnect the charger and the battery
1.Remove the battery from the bathlift. Turn the battery over to
2.Slide the battery charger adapter up into the battery.
3.Plug the battery charger adapter into a wall outlet.
Risk of Injury
Never touch the battery’s charge contacts.
CAUTION
Risk of Damage
When charging the battery, pay careful attention to the
sequence of steps.
room.
automatically when the battery is fully charged.
in reverse order.
expose the slots for the battery charger adapter.
3 SETUP
Part No 1167607
9Invacare®
Rio™ H605
3 SETUP
1
2
1
2
2
3
3.2Assembly
Invacare®
Rio™ H60510Part No 1167607
3.3Setting Up the Bathlift in the Bathtub
1
2
3
CAUTION
Risk of Tipping
Check that the device is seated correctly. When the device is
loaded, the suction cups should not come loose.
Risk of Pinching
Handle the backrest from the sides only.
Risk of Damage
Do not move the basic frame again after you have set it up in
the bathtub.
Before setting up the device, clean the bathtub and the suction cups.
3 SETUP
Part No 1167607
11Invacare®
Rio™ H605
Loading...
+ 25 hidden pages