General ABG14FB, ABG14FBBJ, AOG14FSDJ, ABG14UB, ABG14UBBJ, AOG14USDJL Technical Manual
R410A
2 . FLOOR / CEILING TYPE :
AB 14FBBJ, AB 14UBBJ
D2D_AB001E/01
2005.12.19
2-1. FEATURE
MODELS :
AB 14FBBJ / AO 14FSDJ
AB 14UBBJ / AO 14USDJL
FLOOR / CEILING TYPE
AB14
FEATURES
Compact design
Symmetrical thin and compact design
Flat and round form
Flexible installation
FLOOR / CEILING TYPE
AB14
FLOOR
Double auto swing
Combination of up/down and right/left air
direction swing allows three-dimensional air
direction control.
Since up/down air direction flaps operate
automatically, according to the operating
mode of the unit, it is possible to set the air
direction based on the operating mode.
Super vane
The double-flap "Super Vane" with newly
developed special configuration boosts
the air flow, sending cool air quickly to
every corner of the room.
CEILING
RIGHT and LEFT
swing
5 steps selectable
UP and DOWN
swing
Swing
Steps
7 steps selectable
Others
Auto Restart
Detachable and Washable Open Panel
Auto Shut Flaps
New modelOld model
Non-operation modeOperation mode
- (02 - 01) -
2-2. REMOTE CONTROLLER
2-2-1.
FLOOR / CEILING TYPE
AB14
WIRELESS REMOTE CONTROLLER
FEATURES
Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible.
Four kinds of timers. Easy operation.
Easy to change transmission code (4 patterns) by button operation.
Built-in timers
Select from four different timer programs (On/Off/Program/Sleep).
Program timer
The program timer operates the ON and OFF timer once within a 24 hour period.
FLOOR / CEILING TYPE
AB14
Sleep timer
The sleep timer function automatically corrects the temperature thermostat setting according to
the time setting to prevent excessive cooling and heating while sleeping.
Cooling operation/dry operation
When the sleep timer is set, the set temperature
automatically rises 1 °C every hour. The set
temperature can rise up to a maximum of 2 °C.
Timer setting
60min.
1 °C
2 °C
Heating operation
When the sleep timer is set, the set temperature
automatically drops 1 °C every 30 minutes. The
set temperature can drop to a maximum of 4 °C.
1 °C
2 °C
3 °C
4 °C
30min.
60min.
90min.
Timer setting
Easy operation
After code change
Mixed-up
• Code selector switch eliminates unit
being wrongly switched.
(Up to 4 codes can be set.)
ABCD
AB
C
D
•Wide and precise
transmitting range.
1. Press the MASTER CONTROL
button for more than five seconds
to start the code change.
2. Press the (+) or (-) button to
select the desired code.
A B C D
3. Press the MASTER CONTROL
button again to end the code
change.
- (02 - 02) -
FUNCTIONS
5
1
START/STOP button
Pressed to start and stop operation
64
Display
2
Set temp./Set time buttons/Set remote controller
custom code buttons
Sets the indoor temp./Sets the current time and on-off time
/Set R.C. custom code
Note:Specifications are based on the following conditions.
Cooling:Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB.
Heating:Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
Coil Dimensions
Coil Dimensions
INDOOR199 × 990 × 655199 × 990 × 655
OUTDOOR530 × 750 × 250530 × 750 × 250
INDOOR320 × 1150 × 790320 × 1150 × 790
OUTDOOR609 × 882 × 339609 × 882 × 339
INDOOR28/37(62/82)28/37(62/82)
OUTDOOR35/37(77/82)35/37(77/82)
LIQUID
GAS
CHARGEg9001000
COOLING21 to 430 to 43
HEATING--6 to 24
m15(chargeless:7.5)15(chargeless:7.5)
m88
mm
252 × 800 × 26.6252 × 800 × 26.6
Copper tubeCopper tube
Aluminium Aluminium
2 × 242 × 24
504 × 658 × 36.38504 × 658 × 36.38
WHITE(5Y9/0.5NN)WHITE(5Y9/0.5NN)
BEIGE(10YR7.5/1.0NN)BEIGE(10YR7.5/1.0NN)
FLAREFLARE
R410AR410A
POEPOE
WirelessWireless
- (02 - 04) -
2-4. DIMENSIONS
2-4-1. OUTDOOR UNIT
MODELS : AO 14F, AO 14U
250
250
250
250
750
750
750
750
FLOOR / CEILING TYPE
AB14
100
100
100
100
60
60
60
60
13
13
13
95
95
95
95
285
285
285
285
13
540
540
540
540
(Unit : mm)
530
530
530
530
FLOOR / CEILING TYPE
AB14
Side viewFront view
MOUNTING POSITION
When there are obstacles at the
back or front sides.
AIR
600 mm
or more
100 mm
or more
When there are obstacles at the
back, side(s), and top.
600 mm
(
Ser
v
or
i
c
e s
pace
m
o
r
)
AIR
e
100 mm
or
m
o
r
e
600 mm or more
300 mm
or more
When there are obstacles at the
back, side with the installation of
more than one unit.