General ABG14FB, ABG14FBBJ, AOG14FSDJ, ABG14UB, ABG14UBBJ Technical Manual

...
R410A
2 . FLOOR / CEILING TYPE :  AB 14FBBJ, AB 14UBBJ
D2D_AB001E/01
2005.12.19
2-1. FEATURE
MODELS : AB 14FBBJ / AO 14FSDJ AB 14UBBJ / AO 14USDJL
FLOOR / CEILING TYPE
AB14
FEATURES
Compact design
Symmetrical thin and compact design Flat and round form
Flexible installation
FLOOR / CEILING TYPE
AB14
FLOOR
Double auto swing
Combination of up/down and right/left air direction swing allows three-dimensional air direction control. Since up/down air direction flaps operate automatically, according to the operating mode of the unit, it is possible to set the air direction based on the operating mode.
Super vane
The double-flap "Super Vane" with newly developed special configuration boosts the air flow, sending cool air quickly to every corner of the room.
CEILING
RIGHT and LEFT
swing
5 steps selectable
UP and DOWN
swing
Swing
Steps
7 steps selectable
Others
Auto Restart
Detachable and Washable Open Panel
Auto Shut Flaps
Non-operation mode Operation mode
- (02 - 01) -
2-2. REMOTE CONTROLLER
2-2-1.
FLOOR / CEILING TYPE
AB14
WIRELESS REMOTE CONTROLLER
FEATURES
Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible.
Four kinds of timers. Easy operation.
Easy to change transmission code (4 patterns) by button operation.
Built-in timers
Select from four different timer programs (On/Off/Program/Sleep).
Program timer
The program timer operates the ON and OFF timer once within a 24 hour period.
FLOOR / CEILING TYPE
AB14
Sleep timer
The sleep timer function automatically corrects the temperature thermostat setting according to the time setting to prevent excessive cooling and heating while sleeping.
Cooling operation/dry operation
When the sleep timer is set, the set temperature automatically rises 1 °C every hour. The set temperature can rise up to a maximum of 2 °C.
Timer setting
60min.
1 °C
2 °C
Heating operation
When the sleep timer is set, the set temperature automatically drops 1 °C every 30 minutes. The set temperature can drop to a maximum of 4 °C.
1 °C
2 °C
3 °C
4 °C
30min.
60min.
90min.
Timer setting
Easy operation
After code change
Mixed-up
• Code selector switch eliminates unit being wrongly switched. (Up to 4 codes can be set.)
A B C D
A B
C
D
•Wide and precise transmitting range.
1. Press the MASTER CONTROL button for more than five seconds to start the code change.
2. Press the (+) or (-) button to select the desired code.
A B C D
3. Press the MASTER CONTROL button again to end the code change.
- (02 - 02) -
FUNCTIONS
5
1
START/STOP button
Pressed to start and stop operation
64
Display
2
Set temp./Set time buttons/Set remote controller custom code buttons
Sets the indoor temp./Sets the current time and on-off time /Set R.C. custom code
FLOOR / CEILING TYPE
AB14
3
2
9
10
13
1
7
11
12
14
8
3
Master control button/
Code change
Selects the operating mode (AUTO, HEAT, FAN, COOL, DRY). Start/end R.C. custom code change. (Max. 4 types)
4
Sleep timer button
Pressed to select sleep timer.
5
Signal transmitter
6
Timer button
FLOOR / CEILING TYPE
AB14
Pressed to select the timer mode. (OFF TIMER, ON TIMER, PROGRAM TIMER, TIMER RESET)
7
Fan control button
Selects the fan speed (AUTO, LOW, MED, HIGH).
8
Battery compartment lid
9
Air flow direction vertical set button
TEST
RUN
15
10
Air flow direction vertical swing button
Display panel
16
17
18
SPECIFICATION
19
20
21
22
23
11
Air flow direction horizontal swing button
12
Air flow direction horizontal set button
13
Time adjust button
Sets the current time.
14
ACL button
Used when replacing batteries or change the code.
15
Test run button
Used when testing the air conditioner after installation.
16
Transmit indicator
17
Clock display
18
Master control display
19
Timer mode display
20
Fan speed display
21
Set temperature display
22
Timer set indicator
23
Temperature set indicator
SIZE (H x W x D mm) 160 x 56 x 20
WEIGHT ( g ) 120
ACCESSORY Holder
- (02 - 03) -
2-3. SPECIFICATIONS
AB 14FBBJ AB 14UBBJ
AO 14FSDJ AO 14USDJL
230V 50Hz 230V 50Hz
198-264V 50Hz 198-264V 50Hz
Fin Pitch
1.2 1.2
Fin Pitch
1.45 1.45
6.35(1/4 inc.) 6.35(1/4 inc.)
12.7(1/2 inc.) 12.7(1/2 inc.)
UNIVERSAL MODELS
Outer diameter 26.0 / Inner diameter 21.5
ABS
TYPE
MODEL NAME
INDOOR
OUTDOOR
POWER SOURCE
AVAILABLE VOLTAGE RANGE
CAPACITY
COOLING
RATED
HEATING
RATED
INPUT POWER
kW
CURRENT
A
STARTING CURRENT
kW/kW
MOISTURE REMOVAL
AIR CIRCULATION COOL/HEAT
INDOOR
m3/h
OUTDOOR
FAN SPEED COOL/HEAT INDOOR
r.p.m
OUTDOOR OUTDOOR
FAN TYPE x Q'ty
FAN MOTOR OUTPUT
W
HEAT EXCHANGER TYPE
INDOOR
Coil
Fin
OUTDOOR
Coil
Fin
CASING COLOR
DIMENSIONS H × W × D NET
mm
GROSS INDOOR
OUTDOOR
REMOTE CONTROLLER TYPE
DRAIN PIPE MATERIAL
SIZE
kg(lbs)
PIPE
CONNECTION METHOD
SIZE
mm
MAX LENGTH
MAX HEIGHT
WEIGHT
NET / GROSS
OPERATION(OUTDOOR)
°C
REFRIGERANT TYPE
REFRIGERANT OIL
TYPE
Rows x Stages
mm
Rows x Stages
mm
EUROPEAN ENERGY LABEL
EER
COP
OUTPUT
COMPRESSOR
TYPE
STARTING METHOD
NOISE LEVEL (SOUND PRESSURE)
COOL/HEAT
INDOOR
dB(A)
FLOOR / CEILING TYPE
AB14
COOLING RATED 1.39 1.42
HEATING RATED - 1.35
COOLING RATED 6.3 6.3
HEATING RATED - 6.0
COOLING 3.02 2.82
HEATING - 3.48
High 640/- 640/640
Med 560/- 560/560
Low 480/- 480/480
Quiet - -
High 1600/- 1600/1600
Low - 950/950
High 850/- 850/850
Med 760/- 760/760
Low 670/- 670/670
Quiet - -
High 740/- 740/740
Low - 440/440
INDOOR Sirocco × 2 Sirocco × 2
OUTDOOR Propeller × 1 Propeller × 1
INDOOR 16 16
OUTDOOR 21 21
High 41(Floor console) , 40(Under ceiling) 41/41(Floor console) , 40/40(Under ceiling)
Med 38(Floor console) , 37(Under ceiling) 38/38(Floor console) , 37/37(Under ceiling)
Low 35(F loor console) , 34(Under ceiling) 35/35(Floor console) , 34/34(Under ceiling)
COOLING TYPE HEAT PUMP TYPE
COOLING B C
kW 4.20 4.00
BTU/h 14300 13700
kW
BTU/h - 16000
A 31 31
l/h (pints/h) 1.5(3.2) 1.5(3.2)
W 1150 1150
Permanent Starting Condenser Permanent Starting Condenser
-
49/- 49/50
ROTARY ROTARY
Copper tube Copper tube
Aluminium Aluminium
2 × 12 2 × 12
4.70
FLOOR / CEILING TYPE
AB14
Note: Specifications are based on the following conditions. Cooling: Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB. Heating: Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB. Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
Coil Dimensions
Coil Dimensions
INDOOR 199 × 990 × 655 199 × 990 × 655
OUTDOOR 530 × 750 × 250 530 × 750 × 250
INDOOR 320 × 1150 × 790 320 × 1150 × 790
OUTDOOR 609 × 882 × 339 609 × 882 × 339
INDOOR 28/37(62/82) 28/37(62/82)
OUTDOOR 35/37(77/82) 35/37(77/82)
LIQUID
GAS
CHARGE g 900 1000
COOLING 21 to 43 0 to 43
HEATING - -6 to 24
m 15(chargeless:7.5) 15(chargeless:7.5)
m 8 8
mm
252 × 800 × 26.6 252 × 800 × 26.6
Copper tube Copper tube
Aluminium Aluminium
2 × 24 2 × 24
504 × 658 × 36.38 504 × 658 × 36.38
WHITE(5Y9/0.5NN) WHITE(5Y9/0.5NN)
BEIGE(10YR7.5/1.0NN) BEIGE(10YR7.5/1.0NN)
FLARE FLARE
R410A R410A
POE POE
Wireless Wireless
- (02 - 04) -
2-4. DIMENSIONS
2-4-1. OUTDOOR UNIT
MODELS : AO 14F, AO 14U
250
250
250
250
750
750
750
750
FLOOR / CEILING TYPE
AB14
100
100
100
100
60
60
60
60
13
13
13
95
95
95
95
285
285
285
285
13
540
540
540
540
(Unit : mm)
530
530
530
530
FLOOR / CEILING TYPE
AB14
Side view Front view
MOUNTING POSITION
When there are obstacles at the back or front sides.
AIR
600 mm or more
100 mm or more
When there are obstacles at the back, side(s), and top.
600 mm
(
Ser
v
or
i
c
e s
pace
m
o
r )
AIR
e
100 mm
or
m
o
r
e
600 mm or more
300 mm or more
When there are obstacles at the back, side with the installation of more than one unit.
AIR
600 mm or more
600 mm or more
300 mm or more
- (02 - 05) -
2-4-2. INDOOR UNIT
MODELS : AB 14F, AB 14U
FLOOR / CEILING TYPE
AB14
6
1 2
Side view
1
2
Rear view
(Unit : mm)
45
FLOOR / CEILING TYPE
AB14
3
1
Refrigerant piping flare connection (Gas)
2
Refrigerant piping flare connection (Liquid)
3
Drain piping connection (Drain pipe : I.D. 25 O.D. 29 L 700)
4
Knock out hole for drain piping
5
Knock out hole for refrigerant piping
6
Hole for lifting bolt (Use M10 screw bolt)
990
500 245
65
655
530
45
125
100 hole
50 hole
100 hole
Wall bracket
Side of set
65
Bottom view
3
- (02 - 06) -
MOUNTING POSITION
Floor
(Unit : mm)
FLOOR / CEILING TYPE
AB14
Left Right
300 or more300 or more
Ceiling
FLOOR / CEILING TYPE
AB14
Left
150 or more 300 or more
Indoor unit
Ceiling
2300 or more
20 or more
1000 or more
Obstruction
Right
- (02 - 07) -
2-5. REFRIGERANT CIRCUIT
MODELS : AB 14F / AO 14F
FLOOR / CEILING TYPE
AB14
FLOOR / CEILING TYPE
AB14
MODELS : AB 14U / AO 14U
- (02 - 08) -