3
COPPER
TUBING
PLASTIC
TUBING
Connect by-pass pipe to collar and humidifier cabinet. Using holes at
top and bottom of side panel discharge, pierce 2 self tapping screws
through by- pass pipe.
Mount the self tapping saddle valve on either a cold or a hot water
pipe. A side or top mount is best to avoid clogging from pipe
sediment. Connect 1/4” O.D. tubing to the saddle valve. Copper
tubing requires a brass compression nut and brass sleeve. Plastic
tubing requires a brass insert inside the tubing, a plastic sleeve on
the outside with a brass compression nut.
NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN
CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT.
INSTALLATION OF THIS SADDLE VALVE MUST MEET OR
EXCEED LOCAL CODES AND ORDINANCES.
4
Select location on vertical surface of warm or return air plenum for
mounting humidifier. Tape mounting template in place making sure the
template is level. Do not install humidifier or 7" bypass pipe where the
blanked off ends of a cooling coil will restrict air flow to the humidifier.
Extend horizontal centerline from template to the adjacent plenum. Scribe
7” circle 10” to 15” from side of humidifier, on cabinet centerline, using
connecting collar as guide.
Cut out center section of template and 7” hole. Humidifier is self
retaining. Slide top side in first, then slide chassis down. Level
chassis and install center screws. If by-pass pipe installs to
opposite side of chassis, bend clip on side discharge, remove side
discharge, and reinstall discharge to opposite side of chassis.
Install remaining four corner screws.
1
2
PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before
beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures
exceed 200 degrees F. When wiring into a multi-speed blower circuit see Step 7D.
FOR INSTALLATION ON A VERTICAL
PLENUM SURFACE OF ANY
FORCED AIR FURNACE
INSTALLER: PLEASE FILL OUT AND MAIL GUARANTEE CARD AFTER INSTALLATION
IS COMPLETE. LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER
INSTALLATION: The humidifier may be mounted with
the 7" outlet to the right or left by inverting the cabinet and
reversing the positions of the distributor trough and drain
pan. The humidifier may be mounted on the warm or
return air plenum with equal efficiency.
See Typical Installations.
ADDITIONAL MATERIALS THAT MAY BE NECESSARY:
1. 1/4" diameter plastic supply tubing or 1/4" copper
supply tubing for hot water applications
2. 7" diameter galvanized by-pass pipe
3. electrical wire and wire nuts
4. air pressure switch (G.F. Model #12500 suggested)
950 SERIES
FLOW-THROUGH
BYPASS HUMIDIFIER
R
HIGH BOY COUNTER-FLOW LOW BOY
RETURN AIR
RETURN AIR
RETURN AIR
WARM AIR
WARM AIR
WARM AIR
WARM AIR
GENERALAire AC SERIES
HIGH EFFICIENCY AIR CLEANER
R
DRAIN
DRAIN
DRAIN
Fresh Indoor Air Quality
Connect 1/4" water supply tube to brass filter at inlet of solenoid.
DO NOT USE PLASTIC TUBING IN CONTACT WITH ANY
HOT PLENUM SURFACE OR DUCT. IF USING PLASTIC
TUBING, USE TUBE INSERT P189 AND PLASTIC
COMPRESSION SLEEVE P190 (AVAILABLE AS PART OF
ASSEMBLY 747-38 TUBING KIT).
SADDLE VALVE INSTALLATION INSTRUCTIONS
Copper Pipe
1. Retract piercing pin into valve body by turning handle
counterclockwise.
2. Screw valve body into upper bracket and tighten.
3. Place rubber gasket over piercing pin.
4. Assemble saddle valve over copper pipe using enclosed screws, �
nuts and lower bracket.
5. Tighten screws evenly and firmly. Brackets should be parallel.
6. Complete compression connection to saddle valve outlet.
7. Turn handle clockwise to pierce tubing and close saddle valve.
8. Turn handle counterclockwise to open saddle valve, leave open for �
several seconds to flush dirt from pipe and tubing.
Steel, Brass or Hard Plastic Pipe
1. Shut off water supply and drain pipe.
2. Turn handle clockwise to expose piercing pin and close saddle
valve.
3. Place rubber gasket over piercing pin.
4. Drill 1/8" hole in pipe using a hand crank drill to avoid shock hazard.
5. Assemble saddle valve over steel, brass or hard plastic pipe using �
enclosed screws, nuts and lower bracket.
6. Tighten screws evenly and firmly. Brackets should be parallel.
7. Complete compression connection to saddle valve outlet.
8. Turn handle counterclockwise to open saddle valve, leave open for �
several seconds to flush dirt from pipe and tubing.
Threaded Pipe Fittings
1. Turn handle clockwise to expose piercing pin and close saddle
valve.
2. Seal valve body threads using pipe tape or sealant.
3. Install valve into 1/8" NPT fitting.
4. Complete compression connection to saddle valve outlet.
5. Turn handle counterclockwise to open saddle valve, leave open for
several seconds to flush dirt from pipe and tubing.
5
6
1. Follow the installation instructions supplied with
the humidistat.
2. To remove the humidistat from the base, squeeze
the louvered base at the top and bottom.
3. Before wall mounting, please remove the gasket.
�
4. Before return air duct mounting, please remove the
breakout piece.
AC L
AC N
HUM
SNSR
OUTDOOR TEMP. SENSOR
(NOT USED IN MANUAL MODE)
HUMIDIFIER 24V.
SOLENOID VALVE
OR 24V. DRUM MOTOR
727-58 24 V. TRANSFORMER
OR 24 VAC POWER SUPPLY
SWITCHED WITH FURNACE OPERATION
JUMPER WIRE
E2 HUMIDISTAT
7A
7B
7C
7D
7
ACC
EAC
(HOT)
C
115v.
60CY.
ON-OFF SWITCH
COMMON LEAD
FURNACE
C
HI
LO
GA50
CURRENT
SENSING
RELAY
MULTI
SPEED
BLOWER
MOTOR
AC L
AC N
HUM
SNSR
24V. SOLENOID VALVE
727-58 24 V. TRANSFORMER
(HOT)
C
115v.
60CY.
ON-OFF SWITCH
AC L
AC N
HUM
SNSR
24V. SOLENOID VALVE
727-58 24 V. TRANSFORMER
L1
C
NO
(HOT)
L2
115v.
60CY.
ON-OFF SWITCH
12500 AIR
PRESSURE SWITCH
AC L
AC N
HUM
SNSR
24V. SOLENOID VALVE
727-58 24 V. TRANSFORMER
HUM
FURNACE
CONTROL BOARD
C
24v.
60CY.
AC L
AC N
HUM
SNSR
24V. SOLENOID VALVE
FURNACE
BOARD
3
INSTALLATEUR : VEUILLEZ REMPLIR ET POSTER LA CARTE DE GARANTIE UNE FOIS L'INSTALLATION
TERMINÉE. LAISSER LES DIRECTIVES D'INSTALLATION AU PROPRIÉTAIRE DE LA MAISON.
INSTALLATION: L'humidificateur devrait être monté avec le débouché
de 7 po à gauche ou à droite, en inversant le boîtier et les positions de
la goulotte du distributeur et du bac de vidange. L'humidificateur fournit
le même rendement, qu'il soit installé sur un plénum d'air chaud ou sur
un plénum de reprise d'air. Voir les Installations Typiques.
MATÉRIAUX ADDITIONNELS POUVANT ÊTRE REQUIS :
1. Tube d'alimentation en plastique de 1/4 po de diamètre ou
tube d'alimentation en cuivre de 1/4 po pour les applications
pour eau chaude
2. Tuyau de dérivation galvanisé de 15 cm (6 po)
3. fil électrique et serre-fils
4. Commutateur de pression d'air (G.F. modèle n° 12500 suggéré)
HUMIDIFICATEUR À
DÉRIVATION VENTILÉE
R
TUYAUX EN
CUIVRE
TUYAUX EN
PLASTIQUE
Connecter le tuyau de dérivation au collier et au boîtier de
l'humidificateur.
En utilisant les trous en haut et le fond de la sortie, percez deux vis par
la pipe.
Monter le robinet-vanne à étrier autotaraudeur sur un tuyau d'eau chaude ou d'eau
froide. Un montage latéral ou sur le dessus est idéal pour éviter un engorgement
causé par les sédiments du tuyau. Connecter un tuyau d'un diam. ext. de 6 mm (1/4
po) au robinet-vanne à étrier. Les tuyaux en cuivre exigent un écrou à compression
et un manchon en laiton. Les tuyaux en plastique exigent un insert en laiton à
l'intérieur des tuyaux et un manchon en plastique à l'extérieur avec un écrou à
compression. REMARQUE : NE PAS UTILISER DE TUYAUX EN PLASTIQUE
AVEC DE L'EAU CHAUDE OU SUR UNE SURFACE DE CONTACT CHAUDE DE
PLÉNUM OU DE CONDUIT. L'INSTALLATION DE CE ROBINET-VANNE À
ÉTRIER DOIT RESPECTER OU DÉPASSER LES EXIGENCES DES CODES
LOCAUX ET AUTRES ORDONNANCES.
4
FLUX VERS LE HAUT
FLUX VERS LE BAS
SOUS-SOL
REPRISE AIR
REPRISE AIR
REPRISE AIR
AIR CHAUD
AIR CHAUD
AIR CHAUD
GENERALAire SÉRIES AC
HAUT RENDEMENT FILTRE À AIR
R
DRAIN
DRAIN
DRAIN
POUR UNE INSTALLATION SUR LA
SURFACE VERTICALE DU PLÉNUM DE
N'IMPORTE QUELLE FOURNAISE À AIR
CHAUD PROPULSÉ
PRÉCAUTION : L'installateur doit être un technicien qualifié et expérimenté. Couper l'alimentation électrique
avant de commencer l'installation. Ne pas installer l'appareil dans un endroit où la température peut descendre
sous 0 °C (32 °F) ou si la température du plénum dépasse 93 °C (200 °F). Lors d'un branchement à un circuit de
ventilateur à plusieurs vitesses, voir l'étape 7D.
SÉRIE 950
1
2
1
2
Choisir l’emplacement sur la paroi verticale de la chambre à air de retour, puis y
fixer le gabarit en prenant soin de le placer bien au niveau. Ne pas installer
l'humidificateur ou le tuyau de dérivation de 18 cm (7 po) à l'endroit où l'extrémité
de la plaque d'obturation d'un serpentin refroidisseur pourra restreindre le débit
d'air vers l'humidificateur. Prolonger la ligne horizontale depuis le milieu du
gabarit jusqu’à la chambre à air voisine. Marquer un cercle de 7 po à une
distance de 10 à 15 po du côté de l'humidificateur, sur la ligne centrale du boîtier,
à l'aide d'un collier de raccordement pour guider.
Découper la section centrale de la matrice et le trou de 7 po. Le
châssis de l’humidificateur est autonome; insérer la partie
supérieure en la glissant, puis faire glisser tout le châssis vers le
bas. Les châssis de niveau et installent les vis centrales. Si la pipe
installe sur le côté opposé du châssis, agrafe de fléchissez sur le
châssis, enlevez la sortie latérale, et installez sur le côté opposé du
châssis. Installez les quatre vis restantes.
Fresh Indoor Air Quality