Frigidaire FFTA0833U10, FFTA1033U10, FFTA1033U20, FFTA1233U10, FFTA1233U20 Installation Guide

...
0 (0)

Installation Instructions

READ BEFORE INSTALLING UNIT

For Through-the-Wall Air Conditioners

INSTALLATION WARNINGS AND CAUTION

Carefully read the installation manual before beginning. Follow each step as shown.

Observe all local, state, and national electrical codes and by qualified, licensed, authorized personnel only. Pay attention to danger and safety notices.

To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed.

Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.

Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time.

Handle air conditioner with care.

Make sure air conditioner does not fall during installation.

Do This First (for existing sleeve)

Note that the air conditioner dimensions are: 24" wide,14 1 2 " high, and 19" deep (without front). Install air conditioner according to these installation instructions to achieve the best performance. Save these installation instructions for future reference.

NOTE:

DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED HERE

Items in Kit

You may not need all parts in the kit. Discard unused parts.

No.

Hardware

 

Qty.

No.

Hardware

Qty.

 

 

 

 

 

 

1

Centering/Support Blocks ( 4 1 2” x 31 2 ” x 11 2 ” )

2

9

Trim Frame (top & bottom legs)

2

 

 

 

 

 

 

2

Stuffer Seal (1” x 1 1 2 ” x 84” )

1

10

Ground Wire (green)

1

 

 

 

 

 

 

 

 

3

Seal (1” x 1 1

2 ” x 25”

)

3

11

Tooth washer for grounding screw

2

 

 

 

 

 

 

 

 

4

Seal (1” x 1 1

2 ” x 14”

)

2

12

Grounding Screw

1

 

 

 

 

 

 

 

5

Seal (1” x 3/8” x 25”

)

3

13

Grille Aluminum

1

 

 

 

 

 

 

 

6

Seal( 1” x 3/8” x 14”

)

2

14

Nuts (plastic)

4

 

 

 

 

 

 

 

7

Seal (1” x 3/4” x 14”

)

2

15

Screw w/washer

4

 

 

 

 

 

 

8

Trim Frame (side legs)

2

 

 

 

 

 

 

 

 

 

 

 

66129927394

1

Installation Instructions

Common Wall-Sleeve Dimensions

1. Identify the wall-sleeve brand for your installation, from the chart below.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16”, 17 ½”, or 22”

 

 

 

 

 

 

 

16”, 17 ½”, or 22”

 

 

 

 

 

 

 

16”, 17 ½”, or 22”

GE/Hotpoint/Amana

15 5 8

 

 

 

16 7 8

 

 

 

 

 

 

25 7 8

17 1 8” or 23”

 

 

 

 

Fedders/Emerson/Friedrich (WSE)*

 

 

 

 

 

 

 

 

16 7 8

 

 

 

18 5 8

 

 

 

 

 

 

 

 

 

 

 

16 7 8

 

 

 

18 5 8

Friedrich (USC)

15 1 2

 

 

25 7 8

16 3 4

For larger sleeves, an adaptor trim kit (EA120T) is available.

IMPORTANT

All wall sleeves used to mount the new air conditioner must be in sound structural condition and have a rear grille that securely attached to the sleeve, or rear flange that serves as a stop for the air conditioner.

For new or replacement installations, a Frigidaire Sleeve Kit (EA108T) is recommended.

NOTE:

When installation is complete, replacement unit must have rearward slope as shown in Fig 1.

Remove old air conditioner from wall sleeve and prepare wall sleeve as follows:

1.Clean interior (do not disturb seals)

2.Check to see that sleeve is securely fastened in wall. Add additional screws or nails as required.

3.Retouch wall sleeve painted surface if needed.

4.If a ground wire or mounting hole does not exist, drill a pilot hole for a grounding screw through the left hand side of the sleeve. Drill in a clear area about 3 inches back from the front edge a 3/16” pilot hole for the ground screw. Pull the loose end of the ground wire out of the front of the sleeve and bend it away from the opening. This will be attached to the air conditioner once installed.

 

Wall Sleeve

1/4” to 5/16”

 

 

3”

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall sleeve to unit

 

Max

3/16” Pilot Hole

 

 

 

 

 

 

 

 

 

Rear

 

Front

Grounding.

1”

 

 

 

 

 

Sleeve

 

 

 

 

 

 

 

 

Level

 

 

 

 

 

 

 

 

 

 

 

Fig.1

 

 

 

Fig.2

2

Frigidaire FFTA0833U10, FFTA1033U10, FFTA1033U20, FFTA1233U10, FFTA1233U20 Installation Guide

Installation Instructions

IMPORTANT

This units increased performance characteristics is the result of having two rear intakes.

It is very important that these installation instructions are followed so your unit can operate at maximum efficiency. If there is an existing sleeve and rear grille, it should be replaced with the one shipped with the unit in the accessory kit.

Existing Frigidaire sleeves may have older single sided intake grilles

• These grilles should be replaced with the dual intake grille supplied with the air conditioner.

Left Intake Grille

Right Intake Grille

New Dual Intake Grille

Left Intake

Right Intake

1.Remove the existing grille and save the mounting screws.

2.Place the grille included with your new air conditioner towards the inside rear of the sleeve.

3.Attach the new grille by aligning the four mounting holes.

4.Re-insert the self-tapping screws into the nylon retainers.