1 Product description
The Eppendorf Microplate VIS, 96/F-PS is suitable for the absorbance
measurement in a plate reader with wavelengths higher than 340 nm.
The products are designed for single use in routine, research and training labs in
the bioscience, industrial and chemical fields. The Eppendorf Microplate VIS,
96/F-PS is intended for use by qualified personnel only.
2 Notes for use
WARNING! Contamination risk from damaged plates during
centrifugation.
The plates withstand heavy loads during centrifugation. However, they
can be destroyed and release the substances they contain if used
improperly.
Always observe the maximum permitted centrifugation forces.
Read the operating manual of the centrifuge used.
Centrifuge stacked plates at lower speed only.
Note that organic solvents may reduce the mechanical load capability
of the plates. If in doubt please contact the Eppendorf Application
Support (support@eppendorf.com).
WARNING! Damages to health due to infectious liquids and
pathogenic germs.
When handling infectious liquids and pathogenic germs, observe the
national regulations, the biological security level of your laboratory,
the material safety data sheets, and the manufacturer's application
notes.
Wear personal protective equipment.
Consult the "Laboratory Biosafety Manual" (Source: World Health
Organization, Laboratory Biosafety Manual, as amended) for
comprehensive regulations on the handling of risk group II germs or
biological materials.
Instructions for use
2
Microplate VIS, 96/F-PS
English (EN)
Only use optically perfect and undamaged products.
Reagents, consumables contaminated by reagents and materials used for
cleaning and disinfecting must be disposed of in accordance with laboratory
regulations.
When using aggressive chemicals like (e. g. acetone) please contact the
Eppendorf Application Support (support@eppendorf.com).
3 Technical data
Material: Polystyrene, colorless
Dimensions: Conforms to ANSI/SLAS 1-2004 through
ANSI/SLAS 4-2004
Operating temperature: -86 °C to +70 °C
Centrifuging: Can be centrifuged up to 3 000 x g**
When arranged in a stack (5 plates) can be
centrifuged up to 300 x g*
Sealing: You can close the plates with Eppendorf Storage
Film or Eppendorf Storage Foil or with the
Eppendorf Lid
Purity: PCR clean
*The centrifugation stability of each plate type generally depends on the
centrifuge and its accessories, the ambient conditions and the liquid used.