Safety Instructions

WARNING: To avoid fire, shock, and serious personal injury, follow all instructions carefully.

1.Read your Owner's Manual carefully before installing the Remote Control or Receiver. Retain Owner's Manual for future reference.

2.Before servicing or cleaning the ceiling fan, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device such as a tag, to the service panel.

ADDITIONAL SAFETY INSTRUCTIONS FOR INSTALLATION

1.To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring.

2.Make certain no bare wires are exposed outside the wire connectors.

3.All wiring must conform to National and Local Electrical Codes.

4.Follow the recommended instructions for the proper method of wiring your new Remote Control or Receiver. If you feel you do not have enough electrical wiring knowledge or experience, have your Remote Control or Receiver installed by a licensed electrician. Any electrical work not described in this manual should be performed by a licensed electrician.

INSTRUCTION TO THE USER (if device contains a digital device)

This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

This equipment has been certified to comply with the limits for a class B computing device, pursuant to FCC Rules. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the user’s authority to operate this equipment.

This Class B digital apparatus meets all requirements of the Canadian

Interference-Causing Equipment Regulations.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use.

2

BP7270-1 5/6/05 1:29 PM Page 3

General

Your Emerson Ceiling Fan/Light Control consists of a hand-held SR110 Remote Control (transmitter) and a SW105 Receiver which is mounted under the fan ceiling cover. The remote control is designed to control your ceiling fan speed, airflow direction, and light intensity.

NOTE: The remote control is to be used only with the following Emerson ceiling fan models: F2100, F2200, CF1, CF2300, CF2400, CF2500, CF2800, CF3900, CF4500 and CF4800.

The SW105 Receiver may also be used with the SW115 Wall Control.

Unpackaging

The carton with the SR110 Remote Control transmitter also contains a storage bracket with two mounting screws.

The carton with the SW105 Receiver also contains a reversing module, seven wire connectors, and four pull chain switch plugs.

IMPORTANT

This Owner’s Manual is divided into two sections. The first section, REMOTE CONTROL PROCEDURES, describes how to install the four alkaline batteries (not supplied) in the remote control transmitter, and how to set the operating frequency of the transmitter and receiver. These instructions must be performed prior to installation of the ceiling fan as described in the second section, CEILING FAN PROCEDURES.

The REV push button changes the airflow direction of the fan blades. The UP (uplight) and DN (downlight) push buttons turn the lights on and off and control the light intensities. The red indicator light will illuminate while any button is pressed, indicating that the battery is good.

The remote control transmitter is powered by four AAA alkaline batteries (not supplied). To prevent possible damage if the batteries should leak, be sure to remove the batteries when the control is not to be used for an extended period of time.

Code switches in the transmitter and receiver may be set in 16 different positions. If your fan and light go on and off without using your control, you may be getting interference from other remote units such as garage door openers, car alarms or security systems. To remedy this situation, simply change the combination code in your transmitter and receiver.

Preset Memory Feature

Your Emerson remote control receiver is equipped with a preset memory feature. The receiver will remember the light intensities and fan speed when the lights and fan are turned off from the wall switch. When the wall switch is turned back on, the lights and fan will resume operation as they were prior to being turned off.

Installation of Battery

1.Remove the battery cover and install four AAA batteries (not supplied), oriented as shown in the battery compartment (Figure 1).

REMOTE CONTROL

PROCEDURES

General

Your Emerson Ceiling Fan/Light Remote Control consists of a hand-held transmitter and a receiver which is mounted under the fan ceiling cover. The remote control is designed to separately control your ceiling fan and light intensities. There are four push buttons (HI, MED, LOW, OFF) to set the fan speed and turn the fan off.

REMOTE CONTROL

TRANSMITTER

CODE

SWITCH

CODE RECEIVER

SWITCH

AAA

AAA

AAA

AAA

 

 

ON

SWITCH LEVERS

 

BATTERY

CODE SWITCH

Figure 1

 

COVER

1 2 3 4

 

3

BP7270-1 5/6/05 1:29 PM Page 4

Setting Operating

Frequency of Transmitter

and Receiver

SCREW (TYPICAL) HOUSING COVER (TYPICAL)

Your remote control transmitter and receiver have code switches which must be set on one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and 4) on the switches are factoryset in the ON (up) position. Do not use this setting. Change the switch settings as follows:

1.Slide the four switch levers (Figure 1) in the remote control transmitter to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down.

2.In the receiver, slide the four switch levers in the same positions as set in the transmitter. Make sure the levers on both switches are in the same positions; otherwise the fan will not operate.

3.Position the batteries in the transmitter battery compartment and replace the battery cover.

CEILING FAN

PROCEDURES

Installation to Operate the Ceiling Fan, Downlight and Uplight

IMPORTANT

It is important that you also follow the installation instructions contained in the Owner’s Manual supplied with your Ceiling Fan. Pay particular attention to the Safety Instructions and WARNING notes.

1.Remove and retain the screws securing the housing cover to the switch housing (Figure 2).

2.All Ceiling Fan Models. Disconnect the motor connector from the wiring harness connector (Figure 2). Remove the knurled nut securing the speed control switch to the switch housing.

 

CAPACITOR

SPEED

SCREW (2)

 

CONTROL

 

SWITCH

MOTOR

KNURLED

CONNECTOR

NUT

 

 

WIRING

 

HARNESS

PULL

CONNECTOR

 

CHAIN PLUG

REVERSING SWITCH

SWITCH HOUSING

 

Figure 2

3.For Ceiling Fan Models CF2400, CF4500 and CF4800 Only. Remove the wire connector joining the three blue wires. (Figure 3). Separate the blue wire coming from the ceiling fan and cap this wire using a wire connector (supplied). On Models CF4500 and CF4800 only, cut the yellow wire coming from the uplight switch; cap the end of this wire coming from the center of the motor using a wire connector. On Model CF2400 only, remove the wire connector joining the two yellow wires; cap the yellow wire coming from the motor using a wire connector (orange wire on older models). Remove the knurled nut securing the uplight switch to the switch housing and remove the uplight switch.

NOTE: Keep the uplight switch if you think you may like to return to manual control in the future.

2SEPARATE BLUE WIRE COMING FROM CEILING FAN AND CAP USING WIRE CONNECTOR

1

REMOVE WIRE

 

CONNECTOR SECURING

 

THREE BLUE WIRES

 

CUT THE

 

YELLOW WIRE

 

3 AND CAP USING

 

WIRE

 

CONNECTOR

 

KNURLED NUT

 

PULL CHAIN

 

PLUG

4 Figure 3

UPLIGHT SWITCH

Loading...
+ 8 hidden pages