SSaa ffee ttyy IInnssttrruu cctt ii oonnss
WARNING: To avoid fire, shock, and serious personal injury, follow all instructions
carefully.
1. Read your Owner's Manual carefully before installing the Wall Control. Retain Owner's Manual for future reference.
2. Before servicing or cleaning the ceiling fan, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device such as a tag, to the service panel.
ADDITIONAL SAFETY INSTRUCTIONS FOR INSTALLATION
1. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring.
2. Make certain no bare wires are exposed outside the wire connectors.
3. All wiring must conform to National and Local Electrical Codes.
4. Follow the recommended instructions for the proper method of wiring your new Wall Control. If you feel you do not have enough electrical wiring knowledge or experience, have your Wall Control installed by a licensed electrician. Any electrical work not described in this manual should be performed by a licensed electrician.
Ceiling Fan/Light
Wall Control Owner's Manual
Part No. BP7413 Form No. F40BP74130000
Printed in China 01/10
READ AND SAVE THESE INSTRUCTIONS
Model Number
SW405
Air Comfort Products
DIVISION OF EMERSON COMPANY
8100 W. Florissant • St. Louis, MO 63136
• 4-Speed Hard Wired Wall Control
• Supplied with Receiver
• Supplied with White, Ivory, and Light Almond Face Plates
• Includes Light Dimming Selection Switch
Model Number
SW406
• 4-Speed Hard Wired Wall Control
• Single Light
• Supplied with White, Ivory, and Light Almond Face Plates
• Use with SW405 (3-way) or SR400
• Includes Light Dimming Selection Switch
Part No. F40BP74130000 Form No. BP7413
Installation of Wall Control
SINGLE-POLE INSTALLATION (Figure 2)
1. Disconnect power at circuit breaker or
remove fuse.
2. Remove faceplate and screws from existing
wall control. Pull control out from the wall box. Determine the “hot” wire and the “load” wire and disconnect these wires from control. Do not attempt to disconnect any wires not already connected to existing control.
3. Before installing wall control, place wall
control in “OFF” mode by pushing “ON/OFF” switch to the “OFF” position.
4. Connect one black wire of wall control to the
“hot” wire. Securely connect wires with wire connectors supplied (Figure 3).
5. Screw wall control into wall box using the
supplied screws. Leave wall control in “OFF” mode until fan installation is completed.
6. The wall control is supplied with a white,
ivory, and almond color switch covers. Choose the finish that best suits your needs and snap the cover onto the wall control (Figure 3).
7. Install decorator wall plate (purchased
separately) using the two screws provided with wall plate. Leave wall control in “OFF” mode until fan installation is completed (Figure 3).
8. Refer to fan Owner’s Manual to complete this
installation.
2 7
Do not connect any neutral (white) wire to this control. Incorrect wiring will damage this control.
WARNING
!
General
Your Emerson Ceiling Fan/Light Wall Control consists of a wall mount transmitter and a receiver which is mounted under the fan ceiling cover. The wall control is designed to separately control your ceiling fan speed and light intensity.
Code switches in the wall control may be set in 32 different positions. If your fan and light go on and off without using your control, you may be getting interference from other wall units such as garage door openers, car alarms or security systems. To remedy this situation, simply change the combination code in your wall control and receiver. (See Figure 1.)
Setting Operating Frequency of
Wall Control
(Figure 1)
Your wall control has code switches which must be set in one of 32 possible code combinations. The five levers (numbered 1, 2, 3, 4, and 5) on the switches are factory-set in the ON (up) position. Change the switch settings as follows:
1. Slide the five switch levers in the wall control
to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down.
2. When the power is restored after installation,
push and hold the fan off button ( ) for 3 to 5 seconds to set the code in the receiver.
3. The sixth switch marked ON and I is for
dimming control of lights: Set switch to ON to allow for dimming of the lights. Set switch to I for no dimming of the lights such as for fluorescent bulbs.
ON - Dim: Incandescent and Halogen Bulbs I - No Dim: Fluorescent and LED Bulbs
Figure 2
Figure 1
LIMITED WARRANTY
What The Warranty Covers:
All products covered by this Owner’s Manual are warranted against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
All components are covered by this warranty for one year from the date you purchased your wall control. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Company Do To Correct Problems:
Emerson Company will replace a defective Emerson Wall Control at no charge to you. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and shipping of the product to Emerson.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE WALL CONTROL TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Company, 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Wall Control should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Company,
• Use of parts or accessories not authorized by Emerson Company,
• Mishandling, improper installation, modifications or damage to your wall control while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are
voided when:
• The original purchaser or user ceases to own the product, or
• The ceiling fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Company. REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
WALL CONTROL
WALL CONTROL CODE SWITCHES
1
23
4
CODE SWITCHES
5I
HOT BLK
NEUTRAL
REMOTE CONTROL RECEIVER LOCATED WITHIN THE CEILING COVER
....
OFF ON
FAN/LIGHT WALL CONTROL
BLACK
BLACK
ON
LOAD
GROUND