5
6
1
5
SkyLine Ovens
User maintenance guide
Cavity filter
2
1. Unscrew the fastener from the centre of the filter.
2. Remove the filter from its housing.
3. Wash the filter either in the dishwasher or by hand with neutral dish washing detergent; then rinse thoroughly.
4. Fit the filter back in place and screw the central fastener to firmly secure it.
1
per
week
Essentia
Planned Maintenance Programmes
In order to ensure the safety and performance of your equipment, it is recommended that regular service is undertaken every 12 months by Electrolux Professional authorised engineers in accordance with the manufacturer recommendations. Please contact your local Electrolux Professional Service Centre for further details of service agreements available.
1
4
2
2
4
1
Cavity and surrounding
area cleaning
1. Perform an automatic cleaning cycle choosing the most appropriate one. High intensity of use requires more frequent cleaning.
2. After each automatic cleaning cycle, clean the inner glass and the internal side of the outer glass proceeding as reported on the manual.
3. Clean the food probe using lukewarm water and dish detergent, avoiding tying the cable of the probe and rinsing with water.
4. Thoroughly clean the facade and the gasket with lukewarm water and a micro-fiber cloth
Cleaning external surfaces
3
daily
Condensate drip collector
3
1. Use water to clean the drain pipe “A” of the drip collector: in case of difficult drainage spray neutral detergent and let it melt the incrustations prior to clean again with a pressure water jet.
2. Remove the metal cover “B” and use the same system to clean the check valve “C”.
3. Use a pipe cleaner with nylon bristles to clean the small gutter “D”.
4
Air filter
1. Unlock the metal frame by unscrewing the fastener and remove it.
2. Remove the filter and washing it with dish detergent.
3. Dry the filter and put it back in the frame.
4. Put the frame back in place and secure it with the screws.
5
Facade gasket
Replace the gasket by:
1. Removing the old gasket from its seat;
2. Cleaning the latter from any traces of dirt;
3. Inserting the new gasket along the entire seat.
per
week
1
per
month
1
every
months
Suggested for you
For more Accessories & Consumables
please look at our Catalogues or contact our Electrolux Professional Service Partner.
Non-stick U-pans with coating
925000 (20mm deep) 925001 (40mm deep) 925002 (60mm deep)
Mesh grilling grid
922713
Non-stick perforated U-pans with coating
922652
Double face griddle
and smooth) 925003
Tray for traditional static cooking
922746
(ribbed
Wash the external surfaces with warm, soapy water. Avoid using detergents containing abrasive substances, steel wool, brushes or steel scrapers. Rinse with a damp cloth and dry carefully. Avoid using chlorine or ammonia-based products. Clean the control panel with a soft cloth dampened with water and, if necessary with neutral detergent. Do not wash the equipment with direct or high pressure jets of water. With the aim of reducing the emission of polluting substances into the atmosphere, it is advisable to clean the equipment (externally and, when neccessary, internally) with products that have a biodegradability exceeding 90%. Electrolux Professional
strongly recommends to use Electrolux Professional approved cleaning agents, rinse and descaling agents to obtain better results and maintain product efficiency over time. Damages caused by cleaning, as a consequence of use of not approved cleaning agents,
rinse and descaling, will be excluded by the warranty.
The operations described must be performed wearing the needed Personal Protection Equipment. Refer to the User Manual.
05UMC13____ENG00
2020-04-02
C23
Clean for ovens
100 bags bucket
0S2392
C25
Rinse for ovens
50 tabs bucket
0S2394
Essentia
Anomaly Description Instructions to User
ACF N°323
ACUM N°200 Electronic Switch off and on the appliance. If the warning persists call service
ASCH N°292 Air filter dirty Clean air filter. Allow oven to cool before cooking. If the warning persists call service
bAtt N°110 Battery is low Call service to replace battery
Beto N°242 / Betc N°243
Betr N°224 Boiler Please verify cooking results. If the message persists, call service
Bhto N°240 / Bhtc N°241 Flap/Chimney Please verify cooking results. If the message persists, call service
BntC N°313
BoLt N°223 Boiler water load
bSHt N°315 / bSOt N°314
butn N°101
Cdo N°260
CFbL N°294
CPUA N°203 / CPUt N°204
CSOt N°311 / CSHt N°312
dESC N°230 Scale in boiler
EbOL N°222 Boiler sensor Cooking without preheating (check results). For restoring full functionality, call service
EbYP N°250 Quenching sensor Consumption increases when cooking. For restoring full functionality, call service
ECEu N°212 / ECEd N°213
EH2O N°327 Water load Check the water is opened and pressure is > 1,5 bar. If the problem persists, call service
ELMb N°322 Humidity sensor Verify cooking results. For restoring full functionality, call service
Eotd N°251 Water supply
Epr1 N°320 / Epr6 N°321
Ertc N°1 Real Time Clock
ESCH N°291 Air filter dirty Clean air filter. Allow oven to cool before cooking. If the warning persists call service.
Estd N°253
Etb N°220
EtUb N°221
EtUC N°211
FILS N°225
FSnr N°293
FU0…FU17 N°400…417 Upper motor Restart the oven. If the message persists, call service
GbCd N°301 / GbbU N°302
GbCU N°300 Cavity burner Check gas is opened, restart the oven. If this doesn’t work, call service
Air filter frame absent
Flap
Boiler temp. sensor
Put the frame back in place and secure it with the screws
Clean the oven manually. Check cooking result. Switch OFF/ON. If message persists, call service
Possible to continue cooking without the boiler functionality. Call service to restore full functionality
Ensure water supply is opened and water filter is clean. If the problem persists, call service
Components overheating
Interface external damage
Cleaning drawer absent
Cooling fan uneffective
Do not switch the oven OFF. Clean air inlet filter. Let the oven to cool down. If the error persists call service.
Press all buttons to possibly unlock the blocked one. If the problem persists, call service
Insert the cleaning drawer is in its housing. If the problem persists, clean the oven manually and call service
The oven will be operative until the components compartment will reach a critical temperature
Electronic Try to switch the oven OFF/ON for resetting the error. If the problem persists, call service
Components overheating
Do not switch the oven OFF. Clean air inlet filter. Let the oven to cool down. If the error persists call service
Run a cleaning program with rinse and descale cycle: use 2 tablets “C25“ only. If the problem persists, call service
Cavity sensor
Possible cooking only with 100°C steam cycles. For restoring full functionality, call service
Open water supply. Pour some water in the cavity filter. Do not splash cavity. If the problem persists, call service.
Food probe failure
Possible to run cycles based on time or accessory USB food probe. For restoring full functionality, call service.
Some functionality missing (for example HCCP). For restoring full functionality, call service.
Drain sensor failure
Boiler scale/water missing
Boiler scale/water missing
Cavity overtemperature
Boiler water supply
Cooling fan uneffective
Boiler burner
Touch models: cooking possible. If the problem persists, call service. Digit models: call service
Cooking performance reduced. To restore full functionality, call service
Wait boiler temperature decrease. Run cleaning and use 2 tabs C25 only. If the problem persists, call service
Possible cooking after a cooling cycle. If the problem persists, call service
Open water supply and restart the oven. If the problem persists, call service
Clean control panel filter. The oven will continue to cook
Check gas is opened, restart the oven. If this doesn’t work, cook without boiler. To restore full functionality, call service
Anomaly Description Instructions to User
GrCo N°325 Misuse Ensure to close the grease collector drain valve before restarting the cleaning cycle
Hd01..03 N°282/254/326
Hd05 N°228
Hd06/07 N°229/261
Water solenoid valve
Water solenoid valve
Water solenoid valve
Hd08 N°264 Pump
Hd11/12 N°262/263
HdPP N°265
Water solenoid valve
Water solenoid valve/Pump
HFnI N°281 ISG valve Possible to cook in convection. To restore full functionality, call service
Htd N°252 Water supply
LPIn N°227 Scale in boiler
MCtM N°201 / MCbM N°202
PdEF
PFAC
SLUS N°226
U015 N°015
Inverter Switch the oven Off/On. If the problem persists, call service
Physical memory failure
Software or hardware
Water supply timeout
Water supply timeout
SCbL N°107 ON/OFF button Cooking is possible. Clean manually the oven. Call service to tesrtore full functionality
bAtt N°110 Clock battery
PCCE N°124 / PCE1 N°125 Parameters If the problem persists call service
USFO N°150 / USFC N°151 / USrE N°152 / USUE N°153 /
USB memory Use a different USB key. If the problem persists call service
USdC N°154 / USFU N°155
Switch the oven Off/On; If the error persists, manually clean/rinse the oven cavity and call service
Restart oven. If the error persists cook in convection or combi under 100°C. Cleaning/Rinse manually, Call service
Switch the oven Off/On; If the error persists, manually clean/rinse the oven cavity and call service
Switch the oven Off/On; If the error persists, manually clean/rinse the oven cavity and call service
Switch the oven Off/On; If the error persists, manually clean/rinse the oven cavity and call service
Switch the oven Off/On; If the error persists, manually clean/rinse the oven cavity and call service
Open water supply. Pour some water in the cavity filter. Do not splash cavity. If the problem persists, call service
Possible cooking in ISG mode. Run cleaning and use 2 tabs C25 only. If the problem persists, call service
Try to switch the oven Off/On. If the problem persists, call service
Parameters memory corrupted. Switch the oven Off/On. If the problem persists, call service
Ensure the water supply is open. Clean water filter. If the problem persists call service.
Ensure the water supply is opened. The message disappears when reaching the right level in the boiler
Some functions clock related will not correctly work. Call service to restore full functionality
Loading...