Datalogic MX-E45, MX-E25 User Manual

4.5 (2)
Datalogic MX-E45, MX-E25 User Manual

MX-E25/45

Industrial Vision Processor with PNP (sourcing) I/0

DESCRIPTION

This guide covers MX-E25/45 Industrial Vision Processor models that contain the letter “P”. For example MX-E25-P-2. These models provide PNP (sourcing) inputs and outputs.

MX-E25/45 offer the most powerful and flexible way to solve even complex machine vision applications.

Rugged IP20 housing

Low Maintenance

16 Inputs and 16 Outputs

Up to 4 GigE cameras

Easily Accessed connectors

SYSTEM SPECIFICATIONS

Industrial Vision Processors

MX-E25: Intel Celeron 1.7 GHz, 2 cores MX-E45: Intel Celeron 2.4 GHz, 2 cores Storage

128 GB SSD GigE camera ports

MX-E25-2/MX-E45-2: 2 ports (all are PoE capable) MX-E25-4/MX-E45-4: 4 ports (all are PoE capable)

All MX-E25/45 Industrial Vision Processors have the following specifications:

HD graphics (1920x1200)

2 x 10/100/1000 Mbps Base-T Network Interface

Ethernet/IP, Modbus TCP, OPC, PROFINET communications supported

1 x RS232 Serial port

16 x Optically Isolated Digital In + 16 x Optically Isolated Digital Out

Microsoft Windows 10 IoT Enterprise 2016 64-bit

GENERAL VIEW

q

w

e

 

1) USB 3.0 Keyboard/Mouse

 

 

 

 

2)

37-pin D-Sub Digital I/O

 

 

 

 

3)

Camera connectors

 

 

 

 

4)

Ethernet 2

 

 

 

 

5)

Ethernet 1

 

 

 

 

6)

COM 1 x RS-232 Serial Port

 

 

 

 

7)

Monitor output: Display Port

 

rt y u i

o

8) Monitor output: DVI-I

 

 

 

 

9)

Supply Voltage Connection

SUPPLY VOLTAGE CONNECTION

Power Connector

Supplied Power Plug

 

+ 24VDC Supply Plus

 

GND Funcional Ground*

 

- 24VDC Supply Minus

 

*Connect the ground using a conductor with minimum 2,5mm2 cross section

HASP KEY USB PORT

1)Reset button

2)USB Port Hasp Key

To enable cameras and licenses, insert the provided Hasp key in the USB port (labeled USB5), located behind the Front Cover.

Behind front Cover

STATUS LEDS AND BUTTONS

1) Power, Green

4)

Run, Green

2)

HDD, Yellow

5)

Power Button

3)

Link, Yellow

6)

Reset Button

Power Button: Press and release to turn on the

 

unit or shut down the OS and switch off the unit.

 

Press and hold to switch off without OS shutdown.

 

Reset Button: Triggers a hardware and PCI reset.

 

The unit is restarted.

Behind Front Cover

COMMUNICATIONS

Camera communication uses Cat6 Ethernet cable and provides POE for M1xx and E1xx cameras. Use only Datalogic provided cables.

DIGITAL I/O CABLES TERMINALS AND CONNECTIONS

Cable

Part Number

 

 

Digital I/O 37-pin to Terminal Block 248-01 10

606-0675-xx

 

 

Digital I/O 37-pin to pigtail (remove one end)

606-0675-xx

 

 

NOTE: Do not disconnect the cable at the connector while power is on.

Pin/Terminal Number

Color Code

Signal Name

1

Black

Input Minus (Note 1)

2

Brown

Input 1- and Event 1-

 

 

 

3

Red

Input 2- and Event 2-

4

Orange

Input 3-

5

Yellow

Input 4-

6

Green

Input 5-

7

Blue

Input 6-

8

Purple

Input 7-

 

 

 

9

Gray

Input 8-

10

White

Input 9-

11

Pink

Input 10-

12

Light Green

Input 11-

13

Black/White

Input 12-

14

Brown/White

Input 13-

 

 

 

15

Red/White

Input 14-

16

Orange/White

Input 15-

17

Green/White

Input 16-

18

Blue/White

Output Plus (Note 2)

19

Purple/White

No Connection

20

Red/Black

No Connection

 

 

 

 

21

Orange/Black

Output

1

 

 

 

 

22

Yellow/Black

Output

2

23

Green/Black

Output

3

24

Gray/Black

Output

4

25

Pink/Black

Output

5

 

 

 

 

26

Pink/Red

Output

6

27

Pink/Blue

Output

7

28

Pink/Green

Output

8

29

Light Blue

Output

9

 

 

 

 

30

Light Blue/Black

Output

10

31

Light Blue/Red

Output

11

32

Light Blue/Blue

Output

12

33

Light Blue/Green

Output

13

34

Gray/Red

Output

14

35

Gray/Green

Output

15

 

 

 

 

36

Purple/Black

Output

16

37

Blue/Black

Output Plus (Note 2)

 

 

NOTES:

 

 

1: Common Minus for input ports (External

Pin 1

Female

12 to 24 VDC Minus)

2: Common Plus for output ports (Not an

 

Connector

 

output

voltage source. External 12 to 24

 

Solder Side

 

VDC Plus is required)

 

 

 

 

 

 

I/O CONFIGURATION

Vision Program Manager (VPM) software installed on the processor is used to create vision programs and configure input and output response. Refer to the Impact Reference Guide for programming details.

EXAMPLE I/O CIRCUIT DIAGRAMS

Input Connection (Sourcing)

Output Connection (Sourcing)

CAMERA CABLES AND TERMINALS CONFIGURATION

Camera trigger and strobe output are provided by an external 6-pin I/O cable with no connection to the Industrial Vision Processor. Use cable 606-0672-xx (unterminated) or cable 606-0674-xx (with terminal block 661-0399 or 248-0140). Refer to the MX-E Series Hardware Guide.

Cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Part Number

 

 

 

Camera Trigger and Strobe 6-pin to Terminal Block 248-0140 or 661-0399

 

606-0674-xx

 

 

 

 

 

Camera Trigger and Strobe: 6-pin to pigtail

 

 

 

606-0672-xx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MECHANICAL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

130

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1,95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2,5

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

33

 

270

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

222

 

 

 

 

 

 

 

 

264

 

 

 

 

 

 

 

 

 

 

204

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

254,75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

128

 

 

 

 

 

 

 

 

 

 

 

 

 

 

121

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL FEATURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply voltage (Vs)

24 VDC ± 25%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current Consumption

Nominal: 5.5 A at 24VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Inputs

 

 

 

16 opto-isolated, see Digital I/O Specifications.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Current

 

 

 

ON: 2.0 mA or more

 

 

 

 

 

 

 

 

 

 

OFF 1: 0.16 mA or less

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Resistance

 

 

 

4.7kΩ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On Current

 

 

 

2.0 mA or more

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off Current

 

 

 

0.16 mA or less

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response time

 

 

 

200µsec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Outputs

 

 

 

16 opto-isolated current sourcing, see Digital I/O

 

 

 

Specifications.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format

 

 

 

Opto-coupler isolated open emitter output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Voltage

 

 

 

35VDC (max)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Current

 

 

 

100mA (per channel max)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output saturation voltage

<1V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Residual Voltage Output

0.5V or less (Output current ≤50mA)

 

 

 

 

On

 

 

 

1.0V or less (Output current ≤100mA)

 

 

 

 

Response time

 

 

 

200µsec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Camera interface

 

 

 

GigE (x 2 or x4 depending on model)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USB Hardware Port

USB 2.0 front covered port for USB Hardware Key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USB Ports

 

 

 

4x USB 3.0 ports for monitor, mouse and keyboard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Graphic Interface

 

 

 

Intel® HD (1920x1200 resolution), DVI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Host Communications:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Communications

1x RS-232 Serial Port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/100/1000 Mbps Ethernet x 2

 

 

 

 

 

 

 

Ethernet

 

 

 

Ethernet/IP, Modbus, TCP, OPC, PROFINET

 

 

 

 

 

 

 

 

 

 

 

 

 

communications supported.

 

 

 

 

 

 

 

PCI connections

 

 

 

1x PCIe x8 + 1 PCI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL FEATURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

 

 

10.03 w x 5.11 h x 10.62 d (in)

 

 

 

 

 

 

 

 

 

 

255 w x 130 h x 270 d (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight

 

 

 

2050 g

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Housing material

Galvanized plate, plastic

 

 

ENVIRONMENTAL FEATURES

Temperature

Operating: 0° to +50° C (+32° to +122° F)

Storage: -20° to +60° C (-4° to +140° F)

 

Relative Humidity (30°)

Operating: 10 to 90%

Storage: 5 to 95%

 

 

 

Vibrations

2 to 8 Hz: 1.75 mm amplitude /

(EN60068-2-6)

9 to 200 Hz: 0,5 g

Shock resistance

11ms (15g)

(EN60068-2-27)

 

 

 

Mechanical protection

IP20

(EN 60529)

 

 

 

SOFTWARE FEATURES

 

 

 

Minimum Impact Software

12.2.2

Version Required

 

 

 

HARDWARE FEATURES

 

CPU

MX-E25: Intel Celeron 1.7 GHz, 2 cores

MX-E45: Intel Celeron 2.4 GHz, 2 cores

 

 

 

System Memory

MX-E25/45 DDR4 RAM 8GB

 

 

Storage

128 GB, SSD, 1 SATA slot

 

 

SUPPORT THROUGH THE WEBSITE

Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com.

For quick access, from the home page click on the search icon , and type in the name of the product you’re looking for. This allows you access to download Data Sheets, Manuals, Software & Utilities, and Drawings.

Hover over the Support & Service menu for access to Services and Technical Support.

PATENT

See www.patents.datalogic.com for patent list.

This product is covered by one or more of the following patents:

Utility patents: EP2517148B1, EP2649555B1, US10095951, US8888003, US8915443, US9396404, US9495607, US9798948, ZL200980163411.X, ZL201080071124.9

SEALS

The Industrial Vision Processor has seals in some areas. The seals must not be broken or removed for any reason. The sealed parts may be opened only and exclusively by Datalogic. Breakage of these seals by a customer shall result in immediate cancellation of the warranty on the entire Industrial Vision Processor.

WARRANTY

The warranty period for this product is 24 months. See General Terms and Conditions of Sales at www.datalogic.com for further details.

CE COMPLIANCE

CE marking states the compliance of the product with essential requirements listed in the applicable European directive. Since the directives and applicable standards are subject to continuous updates, and since Datalogic promptly adopts these updates, therefore the EU declaration of conformity is a living document. The EU declaration of conformity is available for competent authorities and customers through Datalogic commercial reference contacts. Since April 20th, 2016 the main European directives applicable to Datalogic products require inclusion of an adequate analysis and assessment of the risk(s). This evaluation was carried out in relation to the applicable points of the standards listed in the Declaration of Conformity. Datalogic products are mainly designed for integration purposes into more complex systems. For this reason, it is under the responsibility of the system integrator to do a new risk assessment regarding the final installation.

WARNING

This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

FCC COMPLIANCE

Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment.

This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

EAC COMPLIANCE

Customs Union:

The CU Conformity certification has been achieved; this allows the Product to bear the Eurasian mark of conformity.

LEGAL NOTICES

© 2019 Datalogic S.p.A. and/or its affiliates ♦ ALL RIGHTS RESERVED. ♦ Without limiting the rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means, or for any purpose, without the express written permission of Datalogic S.p.A. and/or its affiliates.

Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S. and the E.U.

Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.

Datalogic reserves the right to make modifications and improvements without prior notification.

(821006471 REV B)

Loading...
+ 1 hidden pages